{"product_id":"multivariable-vortex-mass-flow-meter","title":"Multivariable Vortex Flow Meter \u003cbr\u003efor Liquid Flow and Gas Flow \u003cbr\u003e1\/2\" to 72\"","description":"\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eA Vortex flow meter is a flow measurement device best suited for applications where the introduction of moving parts presents problems. They are available in industrial grade, brass or all plastic construction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eVortex flow meters work well with clean liquids, gases, and steam because they provide accurate, reliable measurements in applications with stable, non-viscous, single-phase flow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eVortex flow meters are well-suited for steam applications because they handle high temperatures and pressures and provide accurate volumetric or mass flow measurements when paired with temperature and pressure compensation. Their robust design resists wear from dry or wet steam, making them reliable for saturated and superheated steam in industrial systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eVortex flow meter for liquids, steam \u0026amp; gas shipping from stock \u0026amp; configured for you. EASY to use Industrial Vortex Meters. Check our stock and prices that beats our competitors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!--split--\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003eMultivariable Vortex Flow Meter Specifications\u003c\/h3\u003e\n\u003cdiv class=\"product-bullet-list\"\u003e\n\u003cul\u003e\n\u003cli\u003eWetted Materials: 304 SS\u003c\/li\u003e\n\u003cli\u003eFlow Range:\n\u003cul\u003e\n\u003cli\u003eLiquid: \u003cspan\u003e0.5 fps - 33 fps.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eGas: Large Pipes 5 fps - 213 fps, Small Pipes 13 fps - 213 fps.\u003c\/li\u003e\n\u003cli\u003eSteam: Large Pipes 5 fps - 230 fps, Small Pipes 13 fps - 230 fps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/- 1% of reading\u003c\/li\u003e\n\u003cli\u003eRepeatability: +\/- 0.05% of reading\u003c\/li\u003e\n\u003cli\u003ePipe Size:\n\u003cul\u003e\n\u003cli\u003eInline: 1\/2\" to 4\" 150# ANSI Flange Connections, Up to 12\" available custom.\u003c\/li\u003e\n\u003cli\u003eInsertion: 8\" to 72\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLCD Display\u003c\/li\u003e\n\u003cli\u003eTemperature Accuracy +\/- 1 Deg C\u003c\/li\u003e\n\u003cli\u003eTemperature:\n\u003cul\u003e\n\u003cli\u003eGas: -40°F (-40°C) to 482°F (250°C)\u003c\/li\u003e\n\u003cli\u003eStd Temp Liquid: -40°F (-40°C) to 662°F (350°C)\u003c\/li\u003e\n\u003cli\u003eHigh Temp Liquid: -40°F (-40°C) to 626°F (330°C)[Add $450]\u003c\/li\u003e\n\u003cli\u003eAmbient: -40°F (-40°C) to 131°F (55°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Requirement: 24 VDC, 15 Watts maximum;\u003c\/li\u003e\n\u003cli\u003e3.6 VDC Lithium C Size battery for intrinsic safety mode. Has LCD Display but no 4-20 or ModBus\u003c\/li\u003e\n\u003cli\u003eOutput signals: Modbus RTU, 4–20 mA, and 0-1.0 KHz for flow rate indication\u003c\/li\u003e\n\u003cli\u003eDigital communications: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eMax Pressure: 1.6 MPa, 230 PSIG. (Custom up to 4.0 MPa 580 PSIG)\u003c\/li\u003e\n\u003cli\u003eDisplay: Flow rate, Total flow, Temperature, and Pressure\u003c\/li\u003e\n\u003cli\u003eWiring connection to enclosure size: M20 x 1.5\u003c\/li\u003e\n\u003cli\u003eFactory Final QC Test Certificate\u003c\/li\u003e\n\u003cli\u003eIntegral Electronics\u003c\/li\u003e\n\u003cli\u003eElectronics Enclosure: NEMA 4X \/ IP67\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch5 style=\"text-align: left;\"\u003e\u003cstrong\u003eInstructions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM_VT-222_Vortex_Flowmeter_Quick_Manual_Rev_10k.pdf?v=1770157408\" title=\"Vortex Manual for TacticalFlowMeter Series VT-222 Multivariable Vortex Flow Meters\"\u003e\u003cstrong\u003eTFM Vortex Series VT-222 Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM201_Series-Vortex_flowmeter_manual-R8.pdf?27\" title=\"Vortex Mass Flow Meter Instruction Manual\" target=\"_blank\"\u003e\u003cstrong\u003eTFM Vortex Series VT-201 Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eFlow Range\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eThe Vortex meter has different minimum and maximum flow velocities it can measure based on the fluid type and meter size. Please note the values below for proper sizing of your meter.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSteam:\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e1\/2” ANSI Flange: 4-70m\/s or \u003cstrong\u003e787-13,800 f\/m\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor 13-230 f\/s\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e1” ANSI Flange: 3-70m\/s or \u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003e590-\u003c\/strong\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003e13,800 f\/m \u003c\/strong\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor 9.8-230 f\/s\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e2” to 12” ANSI Flange: 1.5-\u003cwbr\u003e70m\/s \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor \u003c\/span\u003e\u003cstrong\u003e30.2-13,800 f\/m \u003c\/strong\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor 4.92-230 f\/s\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eGas:\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e1\/2” ANSI Flange: 4-65m\/s \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor \u003cstrong\u003e787-12,790 f\/m\u003c\/strong\u003e\u003c\/span\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor 13-\u003c\/span\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e213 f\/s\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e1” ANSI Flange: 3-65m\/s \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor \u003cstrong\u003e590-12, 790 f\/m \u003c\/strong\u003e\u003c\/span\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor 9.8-\u003c\/span\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e213 f\/s\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e2” to 12” ANSI Flange: 1.5-65m\/s or \u003cstrong\u003e300- 12,790 f\/m\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor \u003c\/span\u003e\u003cspan\u003e4.9\u003c\/span\u003e\u003cspan\u003e-213\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003ef\/s\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eLiquid:\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e1\/2” to 12” ANSI Flange: 0.2-10m\/s \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor \u003cstrong\u003e40- 1,968 f\/m \u003c\/strong\u003e\u003c\/span\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor .66-32.8 f\/s\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch3\u003eNominal Vortex Flow Rates for Air\u003c\/h3\u003e\n\u003cp\u003eThe table below gives the minimum, nominal, and maximum velocities for the Vortex Meter for gases to assist users familiar with Thermal Mass Flow Meter sizing guides relative to air, with a density of 0.075 lb\/ft^3 for reference. As the pressure goes up the flows go up as well. For example, if the pressure is DOUBLED, so too does the mass flow. \u003cstrong\u003eDownload chart below \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/VortexFlowRates_2048x2048.png?v=1582566416\" title=\"Multivariable Vortex Mass Flow Meter Flow Rate table\" target=\"_blank\"\u003ehere\u003c\/a\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/VortexFlowRates_2048x2048.png?v=1582566416\" title=\"Vortex Flow Meter Flow Rate Chart\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/VortexFlowRates_2048x2048.png?v=1582566416\" alt=\"Vortex Flow Rate Chart Tactical Flow Meter\" style=\"float: none;\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e IMPORTANT Note to Thermal Mass Flow Meter users...\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDid you know that Multivariable Vortex Flow Meters offer a significant advantage over Thermal Mass Flow Meters when it is not necessary to measure ultra low or ultra high flows? \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDid you know that a Multivariable Vortex Meter is not affected by\u003c\/b\u003e \u003cb\u003egas composition? This means you can change gas composition and STILL report the proper Mass Flow! Why utilize a Gas Chromatograph to determine gas composition to correct your Thermal Mass Flow Meter measurement? If you need ultra low flows it makes sense but if your minimum flows are within the measuring range of a Vortex meter then consider a Multivariable Vortex Mass Flow Meter.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAs well, it is important to note that Thermal Mass Flow Meters are quite sensitive to moisture in the flow stream. The most common undesirable effect is momentary flow spikes that can upset your control system. Vortex Meters, on the other hand are NOT sensitive to moisture in the flow stream and offer a significant advantage over Thermal Mass Flow Meters if such spikes are determined to be undesirable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHave you ever have problems with temperature swings causing your Thermal Mass Flow meter to over or under report the flow measurement? The Multivariable Vortex Mass Flow Meter does not exhibit these symptoms simply because the vortex shedding velocity is not a function of temperature or pressure. And, with the Multivariable Vortex Meters built in Pressure and Temperature sensors you can get true Mass Flow, Pressure, AND Temperature and even gather Volume flow on those rare occasions when deemed necessary. And, you have a true pressure measurement as well as the Mass Flow and temperature. All at a price very competitive with Thermal Mass Flow Meters.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHOWEVER, if you DO need very low or very high flows we suggest the use of Thermal Mass Flow Meters. As well, Thermal Mass Flow Meters are ideal as \"Insertion Meters\" as they are small and if, and ONLY if, there is no moisture, or gas composition changes then the Thermal Mass Flow Meter is a very good choice. Otherwise, the Vortex is the best choice as it has NO sensitivity to the gas composition or droplets or hydrocarbon particulate. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRefer to the chart above for the minimum and maximum flows for the Vortex Mass Flow Meter. Refer to the minimum and maximum velocities for the fluid you wish to use to see if a vortex meter is a good choice. If your flow is within the velocity range of the Vortex meter AND you have moisture or any change in gas composition then a Vortex meter is a better choice over the Thermal Mass Flow Meter.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Note: Vortex Flow Meters want to be rigidly mounted or isolated from vibration to prevent the vibrating energy to be transmitted to the Vortex Piezo Sensors. This can be accomplished by rigid mounts to a solid base or good vibration isolation.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow to use button interface and ModBus RTU video:\u003c\/strong\u003e\u003cstrong\u003eTo get the most out of the video open the link below and print out the document or open it in another window.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/h5\u003e\n\u003c!-- split --\u003e\n\u003ctable style=\"width: 400.667px;\" height=\"400.667px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 119.667px;\"\u003e \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TacticalFlowMeter-Vortex-Display-300px.png?v=1727718820\" loading=\"lazy\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003eSee the video below to see how to use the buttons on the display within the enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFeatures LARGE LCD display, shows the Flow Rate, Total Flow, Temperature, and Pressure in user selectable units.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eMenu\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch2\u003eVortex VT-210 Meter Menu Details\u003c\/h2\u003e\n\u003cp\u003eMENU 22\u003cbr\u003eQ Unit \u0026gt;\u0026gt; l\/m\u003cbr\u003eQ Mode \u0026gt;\u0026gt; Qvw actual (We are measuring volume flow....)\u003cbr\u003eQ Factor \u0026gt;\u0026gt; 2121.47 Do Not Change (This is stamped on the side of the meter)\u003cbr\u003eDensity \u0026gt;\u0026gt; 875 kg\/m3 (Water is 1000)\u003cbr\u003eQ20mA \u0026gt;\u0026gt; 250 (FULL SCALE... If your meter is 250 l\/m)\u003cbr\u003eQ Cut-Zero % \u0026gt;\u0026gt; 5\u003cbr\u003eQ Up Al \u0026gt;\u0026gt; 250 to turn the alarm on at 100%\u003cbr\u003eQ Dn Al \u0026gt;\u0026gt; 25 to turn the alarm at 10% flow\u003cbr\u003eDamp S \u0026gt;\u0026gt; 6\u003cbr\u003eComm Address \u0026gt;\u0026gt; 0\u003cbr\u003eClear Q \u0026gt;\u0026gt; Clears Totalizer, Password = 70\u003cbr\u003e\u003cbr\u003eMENU 33\u003cbr\u003eLanguage \u0026gt;\u0026gt; English\u003cbr\u003ePulse Type \u0026gt;\u0026gt; F_adj\u003cbr\u003ePulse Factor \u0026gt;\u0026gt; 0.01\u003cbr\u003eComm Param \u0026gt;\u0026gt; 9600, No\u003cbr\u003eComm Switch \u0026gt;\u0026gt; ON\u003cbr\u003eP_display \u0026gt;\u0026gt; MEASURE\u003cbr\u003eSet Pc \u0026gt;\u0026gt; 0\u003cbr\u003eP0-Ref \u0026gt;\u0026gt; 101.3KPa\u003cbr\u003eT_display \u0026gt;\u0026gt; MEASURE\u003cbr\u003eSet Tc \u0026gt;\u0026gt; 20 Deg C\u003cbr\u003eT-TYPE \u0026gt;\u0026gt; Pt=100\u003cbr\u003eTn \u0026gt;\u0026gt; 20 Deg C\u003cbr\u003eEnviron-T \u0026gt;\u0026gt; -20 Deg C (-10 C is fine if you do not get them cold.)\u003cbr\u003eQ-adj \u0026gt;\u0026gt; DO NOT change this setting\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003eMENU 44\u003cbr\u003eSignal-TYPE \u0026gt;\u0026gt; LF: DN40-500 Lqd\u003cbr\u003eGain \u0026gt;\u0026gt; G=9\u003cbr\u003eVPP limit \u0026gt;\u0026gt; 100mV\u003cbr\u003eFre-Range \u0026gt;\u0026gt; 11=34-850Hz\u003cbr\u003eWork Type \u0026gt;\u0026gt; Digital\u003cbr\u003ean-noise TYPE \u0026gt;\u0026gt; ANS\u003cbr\u003eSignal-Adj-Set \u0026gt;\u0026gt; FIlter 10 or OFF\u003cbr\u003e50Hz Cut \u0026gt;\u0026gt; ON\u003cbr\u003eK-LINE ADJ \u0026gt;\u0026gt; DO NOT change this setting\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"Multivariable Vortex Meter Dimensions, TacticalFlowMeter.com\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Multivariable_Vortex_Meter_Dimensions._jpg_grande.jpg?v=1555698757\" style=\"float: none;\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHow to Invoke Variable K-Factors in the Tactical Flow Meter Vortex Flow Meter:\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eScreen 33 Instructions are for advanced users only. Do NOT invoke this screen on your meter unless you have a pressing need. It is important to note all settings PRIOR to making any changes. Note: Left button HOLD gets you OUT of menus.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee example spreadsheet \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Vortex_Coefficient_Calibration_1.xlsx?217\" title=\"Example Vortex Calibration Spreadsheet\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Example-FrequencyCalcRev1.xls?215\" title=\"Example VOrtex Calibration Spreadsheet\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Vortex_Coefficient_Calibration_1.xlsx?217\" title=\"Example Vortex Calibration Spreadsheet\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Vortex_Flow_Meter_Calibration_Coefficients_7c6b739e-ca44-45e0-b601-4dd05de6ca44_480x480.png?v=1575080535\" alt=\"\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Example-FrequencyCalcRev1.xls?215\" title=\"Example VOrtex Calibration Spreadsheet\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBefore exiting ensure you SAVE the data and CONFIRM the % numbers are ever increasing in from element 0 to element 4. The Correction ratio must be between 0.8 and 1.2. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #000000; font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 1.4em;\"\u003e\u003cspan style=\"background-color: #ffff00;\"\u003eWhere to get Power Supplies, Gaskets, Nuts and Bolts\u003c\/span\u003e \u003ca title=\"Where to get 24 VDC Power Supplies and flange bolts and gaskets\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Power_Supplies_Bolts_Gaskets_and_more.pdf?v=1605288973\" target=\"_blank\"\u003eLink\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Note: Vortex Flow Meters want to be rigidly mounted or isolated from vibration to prevent the vibrating energy to be transmitted to the Vortex Piezo Sensors. This can be accomplished by rigid mounts to a solid base or good vibration isolation. We show some settings below as examples for your study. The video above shows how to enter the configuration modes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #000000; font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 1.4em;\"\u003e\u003c\/strong\u003e\u003cstrong\u003eTypical Vortex Meter Settings for reading Volume Flow for Liquids with a Full Scale of 250 l\/m for a fluid with a density of 875 kg\/m3 for a 3\" Vortex Meter where the vortex frequency is from 34-850 Hz.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003e3D Files\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eLink to Copyrighted Wafer Meter STEP Files \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" title='Copyrighted STEP Files for TFM 3,4,6 \u0026amp; 10\" Wafer Meters' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFMCopyrightedWaferMeterStep-3-4-6-10-Inch.zip?v=1726764821\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e  3',4\",6\" \u0026amp; 10\" SIZE ANSI 150# Wafer\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLink to Copyrighted FLANGED Meter STEP Files \u003cspan style=\"color: rgb(43, 0, 255);\"\u003ehere \u003cspan style=\"color: rgb(0, 0, 0);\"\u003efrom 0.5 to 2.5\" ANSI 150# Flange \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eLink to Copyrighted FLANGED Meter STEP Files \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/CopyrightedVortex_3-4-5-6-8-10-12Inch_ANSI150.zip?v=1726794333\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003ehere\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e  \u003cstrong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003efrom 3 to 12\" ANSI 150# Flange \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eCut Sheets\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFMV_vortex_data_sheet_Rev_4.pdf?v=1595288115\" title=\"Vortex Meter Cut Sheet Tactical Flow Meter\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eVideos\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eVideo showing User Interface for TacticalFlowMeter.com VT-222 Series Multivariable Vortex Mass Flow Meter:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"ygTNTIO6eyU\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/ygTNTIO6eyU\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eHow to use ModBus Poll to read the totalizer in a Type 2 Vortex Meter.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"93Sufdg7DMU\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/93Sufdg7DMU\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eVideo showing how to use the spreadsheet above and the Front Panel Interface with Menu 33:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"sZOLHFcqHLM\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/sZOLHFcqHLM\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eHow to verify and set up Full Scale and Units:\u003c\/h2\u003e\n\u003cp\u003eRefer to the Vortex Meter LCD Interface Video above for overview and introduction to using buttons. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"gqSA2lck0-E\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/gqSA2lck0-E\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Tactical Flow Meter","offers":[{"title":"1\/2\" \/ ANSI","offer_id":42082404761769,"sku":"Vortex_AN_1_2","price":2600.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ TriClover","offer_id":42082404794537,"sku":"Vortex_TC_1_2","price":2700.0,"currency_code":"USD","in_stock":true},{"title":"3\/4\" \/ ANSI","offer_id":42082404827305,"sku":"Vortex_AN_3_4","price":2800.0,"currency_code":"USD","in_stock":true},{"title":"3\/4\" \/ TriClover","offer_id":42082404860073,"sku":"Vortex_TC_3_4","price":2900.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ ANSI","offer_id":42082404892841,"sku":"Vortex_AN_1","price":2900.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ TriClover","offer_id":42082404925609,"sku":"Vortex_TC_1","price":3000.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ ANSI","offer_id":42082404958377,"sku":"Vortex_AN_1_1_2","price":3300.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ TriClover","offer_id":42082404991145,"sku":"Vortex_TC_1_1_2","price":3400.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ ANSI","offer_id":42082405023913,"sku":"Vortex_AN_2","price":3400.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ TriClover","offer_id":42082405056681,"sku":"Vortex_TC_2","price":3500.0,"currency_code":"USD","in_stock":true},{"title":"2 1\/2\" \/ ANSI","offer_id":42082405089449,"sku":"Vortex_AN_2_1_2","price":3800.0,"currency_code":"USD","in_stock":true},{"title":"2 1\/2\" \/ TriClover","offer_id":42082405122217,"sku":"Vortex_TC_2_1_2","price":3900.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ ANSI","offer_id":42082405154985,"sku":"Vortex_AN_3","price":4300.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ TriClover","offer_id":42082405187753,"sku":"Vortex_TC_3","price":4400.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ ANSI","offer_id":42082405220521,"sku":"Vortex_AN_4","price":5000.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ TriClover","offer_id":42082405253289,"sku":"Vortex_TC_4","price":5100.0,"currency_code":"USD","in_stock":true},{"title":"6\" \/ ANSI","offer_id":42082405286057,"sku":"Vortex_AN_6","price":5800.0,"currency_code":"USD","in_stock":true},{"title":"8\" \/ ANSI","offer_id":42082405351593,"sku":"Vortex_AN_8","price":6800.0,"currency_code":"USD","in_stock":true},{"title":"8\" to 72\" Insertion \/ ANSI","offer_id":46413480132777,"sku":null,"price":6188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM_Vortex_ANSI_Front.webp?v=1758820692","url":"https:\/\/www.tacticalflowmeter.com\/products\/multivariable-vortex-mass-flow-meter","provider":"Tactical Flow Meter","version":"1.0","type":"link"}