{"product_id":"magnetic-flow-meter","title":"Magnetic Flow Meter \u003cbr\u003efor Liquid Flow \u003cbr\u003e1\/2\" to 96\"","description":"\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMagnetic flow meters (MAG flow meters) are volumetric flow meters for measuring CONDUCTIVE LIQUIDS [Not Gases] that operate without any moving parts and are ideal for potable water and wastewater applications as well as ideal for any conductive or water based clean or dirty fluid. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMagnetic flow meters work exceptionally well for slurry and cement applications because they offer obstruction-free flow paths and accurately measure conductive fluids even in the presence of high solids content and abrasive materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMagnetic flow meters will generally not work with hydrocarbons, distilled water, and many non-aqueous solutions as they require a conductive fluid of 5 microSiemens\/cm minimum.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOutstanding 0.5% Accuracy and 40:1 Turndown, in 1\/2\" to 96\" pipes, with the following liquids:  \u003c\/span\u003e\u003cstrong\u003ePotable Water, Well Water, Waste Water, Effluent, Sewage, Sludge, Cement, Oil Well Injection Water, Beer, Wine, Liquor, Fruit Juice, Dairy,  Irrigation MAG Meters, Chemical Reagent, or any electrically conductive liquid. \u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--split--\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003eMagnetic Flow Meter Specifications\u003c\/h3\u003e\n\u003cdiv class=\"product-bullet-list\"\u003e\n\u003cul\u003e\n\u003cli\u003eElectrode Material: 316L SS\u003c\/li\u003e\n\u003cli\u003eWetted Materials: Teflon, 304 SS, \u0026amp; 316 SS\u003c\/li\u003e\n\u003cli\u003eFlow Body Material: 304 SS\u003c\/li\u003e\n\u003cli\u003eFlow Range: 0.3 - 12 m\/s\n\u003cul\u003e\n\u003cli\u003eNominal 0.3 - 10 m\/s for 0.5% Accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/- 0.5% of reading in water (From 0.3 m\/s to 10 m\/s)\u003c\/li\u003e\n\u003cli\u003eRepeatability: +\/- 0.15% of reading\u003c\/li\u003e\n\u003cli\u003ePipe Size: \n\u003cul\u003e\n\u003cli\u003eInline: 1\/2\" to 80\" 150# ANSI flange connections, Up to \u003cspan\u003e2500# available\u003c\/span\u003e custom\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInsertion: 6\" to 96\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTemperature:\n\u003cul\u003e\n\u003cli\u003e  Liquid: 14°F (-10°C) to 350°F (180°C)\u003c\/li\u003e\n\u003cli\u003eAmbient: 14°F (-10°C) to 140°F (60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Requirement: 24 VDC 20 Watts maximum;\u003c\/li\u003e\n\u003cli\u003eOutput signals: Modbus RTU, 4–20 mA, and 0-10 KHz for flow rate indication\u003c\/li\u003e\n\u003cli\u003eDigital communications: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eProof Pressure: 1.6 MPa, 230 PSIG.\u003c\/li\u003e\n\u003cli\u003eLCD Display: Flow rate, Flow rate 0-100%, and total flow\u003c\/li\u003e\n\u003cli\u003eWiring connection to enclosure size: M20 x 1.5\u003c\/li\u003e\n\u003cli\u003eFactory Final QC Test Certificate\u003c\/li\u003e\n\u003cli\u003eIntegral Electronics\u003c\/li\u003e\n\u003cli\u003eElectronics Enclosure: IP65\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ca title=\"In Stock MAG Meters low price R3\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R3.pdf?224\" target=\"_blank\"\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Mag-Meter-Product-Overview.png?v=1234567890\" alt=\"Mag Meter Product Overview\" loading=\"lazy\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eInstructions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eCurrent Version:\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca title=\"MAG-Meter-Quick-User-Manual-Style-2\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/QUICK-User_Manual-MAG-Meter-Style2-R_18.docx.pdf?v=1662738582\" target=\"_blank\"\u003eTFM MAG Meter v2 User Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(33, 43, 54); text-decoration: underline;\"\u003e\u003ca title=\"MAG Meter ModBusRTU Manual Style 2\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG_Meter_ModBusRTU_Style2_Rev3.pdf?v=1662738578\" style=\"color: rgb(33, 43, 54); text-decoration: underline;\" target=\"_blank\"\u003eTFM MAG Meter v2 ModBus RTU Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #212b36;\"\u003eOlder Version:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"MAG-Meter-Quick-User-Manual-and-Wiring-Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/QUICK-User_Manual-MAG-Meter-R7.pdf?221\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eTFM MAG Meter v1 User Manual\u003c\/span\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca title=\"MAG-Meter-Quick-User-Manual-Style-2\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/QUICK-User_Manual-MAG-Meter-Style2-R_18.docx.pdf?v=1662738582\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG_Meter_ModBus_RTU_Rev_4.pdf?v=1689292378\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eTFM MAG Meter v1 ModBus RTU Manual\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eFlow Range\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eThe table below gives a guideline of the nominal maximum GPM for various pipe sizes. \u003cspan style=\"text-decoration: underline;\"\u003e \u003cstrong\u003eFlows in well designed piping systems, to minimize wear and noise, and energy, are typically no more than 10 m\/s max.\u003c\/strong\u003e\u003c\/span\u003e Note these meters can easily go to 12 m\/s for systems, such as high pressure fire fighting systems and blowdown systems. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca title=\"TacticalFlow Meter MAG Meter Flow Rate versus Velocity and Pipe size\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Mag-Meter-FlowRate-Chart-TacticalFlowMeter_0.3_to_12mps.png?v=1625240566\"\u003e \u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Mag-Meter-FlowRate-Chart-TacticalFlowMeter_0.3_to_12mps.png?v=1625240566\" alt=\"Tactical Flow Meter MAG Meter Flow Rate Chart versus velocity and pipe size\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003ca title='1\/2\" to 12\" MAG Meter Dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R4.pdf?v=1588134523\"\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MagMeterDimensions1Inch_to_12_Inch.png?v=1588135093\" alt='1\/2\" to 12\" MAG Meter Dimensions' loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eWiring\/Plumbing\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003ca title=\"MAG meter plumbing requirements R3\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R3.pdf?224\" target=\"_blank\"\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG-Meter-Plumbing-Requirements-1.png?v=1543277467\" alt=\"Mag Meter Plumbing Requirements\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"MAG Meter grounding requirements\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R1.pdf?14794767180491946982\" target=\"_blank\"\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG-Meter-Plumbing-Requirements-2.png?v=1543277514\" alt=\"Mag Meter Grounding Requirements\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"background-color: #ffffff;\"\u003e\u003cstrong\u003eIMPORTANT NOTE:\u003c\/strong\u003e \u003cstrong\u003eThis meter is not a \"Loop Powered\" device, unlike almost all temperature and pressure transducers that are loop powered. This meter takes 500 mA to run so you can see that they can not be Loop Powered. It is CRITICAL that 24 VDC is NOT connected to the 4-20 mA signal lines of COM and I+ where COM is connected to the \"low\" side,-, of the 4-20 mA and the I+ is connected to the \"high\" side,+. Your PLC has a mode in it to read these meters that does NOT involve sending power to the meter. These meters are SOURCING the 24 VDC. Connecting 24 VDC to the Current Output lines may void warranty.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/4-20_mA_Simulation_MAG_Meter.png?v=1573511990\" alt=\"How to Simulate 4-20 mA on the MAG Meter.\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003cp\u003eView video above to see how an INSERTION MAG meter is installed, which is DIFFERENT than the flange meters on this product page. Please visit \u003ca title=\"Tactical Flow Meter, Insertion MAG Meter\" href=\"https:\/\/www.tacticalflowmeter.com\/collections\/magnetic-flow-meters\/products\/insertion-magnetic-flow-meter-1-0-accuracy\" target=\"_blank\"\u003eINSERTION MAG\u003c\/a\u003e meter product listing if you discover you need an Insertion Mag Meter.\u003c\/p\u003e\n\u003cp\u003eNote: The following display orientations can be ordered so the user does not have to orient in the field.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Flow_Meter_Display_DIrection_Guide_R1.png?v=1607378321\" alt=\"Flow Meter Display Direction Guide\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/ANSI_CLASS_Flange_Pressure_Ratings_Chart.png?v=1600810814\" alt=\"ANSI Class Rating Chart from Class 150 to Class 2500\" loading=\"lazy\"\u003e\u003c\/h3\u003e\n\u003ch5\u003e\u003cstrong\u003eRetractor\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/INSERTION_METER_WITH_RETRACTOR.png?v=1662351244\" alt=\"Insertion Mag Meter with Retractor\" loading=\"lazy\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch3 class=\"title style-scope ytd-video-primary-info-renderer\"\u003eFlowmeter Retractor \u0026amp; Hot Tap Insertion Meter Retractor\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe HIGH PRESSURE RETRACTOR works with the INSERTION MAG METER or the INSERTION VORTEX METER.  It is smooth as silk and super strong (2,000 PSIG max).  The flexible design will work well with all brands of insertion flow meters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb\u003eHigh Pressure Retractor Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Overall dimensions:  33.5” x 10.8” x 5.6”\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Anodized aluminum brackets and shear box\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Held together with 304 SS hardware\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Smooth 304 SS  ACME screw drive\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e 304 SS guide rails and bearings for increased load capacity\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Power drill actuated - articulation from 0-27 inches\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e 5\/16” hex driver bit included.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cstrong\u003eCut Sheets\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003e \u003ca style=\"color: #2b00ff;\" title=\"MAG Meter dimensions and installation requirements\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R2.pdf?172\" target=\"_blank\"\u003eMAG Meter dimensions\/ Installation requirements\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003cstrong\u003e \u003ca title='12\" MAG Meter Cut Sheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/12__ANSI_RFF_MAG_meter_Carbon_Steel.pdf?v=1592960175\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e12\" ANSI Raised Face 150# Flange MAG Meter \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/12__ANSI_RFF_MAG_meter_Carbon_Steel.pdf?v=1592960175\" title='12\" MAG Meter Cut Sheet' style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003eCut\u003c\/a\u003e\u003ca title='12\" MAG Meter Cut Sheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/12__ANSI_RFF_MAG_meter_Carbon_Steel.pdf?v=1592960175\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003ca title='8\" MAG Meter Cut Sheet Water Flow Meter Spec Sheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/8__ANSI_RFF_MAG_Meter_Carbon_Steel.pdf?v=1611088922\" style=\"color: #005fff;\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong style=\"color: #2b00ff; text-decoration: underline;\"\u003e8\" ANSI Raised Face 150# Flange MAG Meter Cut sheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003cstrong\u003e\u003ca style=\"text-decoration: underline; color: #005fff;\" title='6\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/6__ANSI_RFF_MAG_meter.pdf?788851432150458519\" target=\"_blank\"\u003e6\" ANSI Raised Face 150# Flange MAG Meter Cut sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003cstrong\u003e\u003ca style=\"text-decoration: underline; color: #005fff;\" title='6\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4__304_SS_ANSI_600_RFF_MAG_meter.pdf?222\" target=\"_blank\"\u003e4\" ANSI \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4__304_SS_ANSI_600_RFF_MAG_meter.pdf?222\" title='6\" ANSI Raised Face Flange MAG meter specifications and dimensions' style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003eRaised\u003c\/a\u003e\u003ca style=\"text-decoration: underline; color: #005fff;\" title='6\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4__304_SS_ANSI_600_RFF_MAG_meter.pdf?222\" target=\"_blank\"\u003e Face 600# Flange MAG Meter \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4__304_SS_ANSI_600_RFF_MAG_meter.pdf?222\" title='6\" ANSI Raised Face Flange MAG meter specifications and dimensions' style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003eCut\u003c\/a\u003e\u003ca style=\"text-decoration: underline; color: #005fff;\" title='6\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4__304_SS_ANSI_600_RFF_MAG_meter.pdf?222\" target=\"_blank\"\u003e sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title='4\" 150# ANSI MAG Flow Meter Cut Sheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4in_304_SS_ANSI_4_in_150_RFF_MAG_meter_Rev3.pdf?v=1629331774\"\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003cspan style=\"color: #005fff; text-decoration: underline;\"\u003e\u003cspan\u003e\u003cstrong\u003e4\" 304 SS ANSI 150# RFF MAG meter CutSheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/4__TriClover_MAG_meter_Dimensions.pdf?v=1658250242\"\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003cspan style=\"color: #005fff; text-decoration: underline;\"\u003e\u003cspan\u003e\u003cstrong\u003e4\" TriClover MAG Meter Cut Sheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_3in_304_SS_150_ANSI_3_in_RFF_Remote_MAG_meter_R1.pdf?v=1623698730\" title='3\" 304 SS ANSI 150# RFF Remote MAG meter CutSheet' style=\"color: #005fff;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan\u003e\u003cstrong\u003e3\" 304 SS ANSI 150# RFF Remote MAG meter CutSheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003ca title='3\" 300# ANSI MAG Meter Cut Sheet and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/3__300_ANSI_RFF_MAG_meter_Cut_Sheet.pdf?v=1615490235\" style=\"color: #005fff;\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e3\" 304 SS ANSI 300# RFF MAG meter CutSheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_3__600_ANSI_RFF_MAG_meter.pdf?v=1615513190\" title='3\" 600# ANSI MAG Meter Cut Sheet and dimensions' style=\"color: #005fff;\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e3\" 304 SS ANSI 600# RFF MAG meter CutSheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4in_304_SS_150_4_in_ANSI_RFF_Remote_MAG_meter_R1.pdf?v=1623698730\" title='4\" 304 SS ANSI 150# RFF Remote MAG meter CutSheet' style=\"text-decoration: underline; color: #005fff;\"\u003e4\" 3\u003c\/a\u003e\u003ca title='4\" 304 SS ANSI 150# RFF Remote MAG meter CutSheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4in_304_SS_150_4_in_ANSI_RFF_Remote_MAG_meter_R2_5752dde6-27a8-4f35-81ba-3d0899b21539.pdf?v=1623712496\" style=\"text-decoration: underline; color: #005fff;\"\u003e04 SS ANSI 150# RFF Remote MAG meter CutShee\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4in_304_SS_150_4_in_ANSI_RFF_Remote_MAG_meter_R1.pdf?v=1623698730\" title='4\" 304 SS ANSI 150# RFF Remote MAG meter CutSheet' style=\"text-decoration: underline; color: #005fff;\"\u003et\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4in_304_SS_150_4_in_ANSI_RFF_Remote_MAG_meter_R1.pdf?v=1623698730\" title='4\" 304 SS ANSI 150# RFF Remote MAG meter CutSheet' style=\"color: #005fff;\"\u003e \u003cspan style=\"text-decoration: underline;\"\u003e \u003c\/span\u003e \u003c\/a\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003ca title='3\" ANSI' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/3__ANSI_RFF_Carbon_Steel_MAG_meter.pdf?11025291778038164151\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e\u003cstrong\u003e3\" ANSI Raised Face 150# Flange MAG Meter Cut sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003cstrong style=\"color: #2b00ff; text-decoration: underline;\"\u003e\u003ca title='3\/4\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_3_4__304_SS_ANSI_RFF_MAG_meter.pdf?v=1589319650\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e3\/4\" ANSI Raised Face 150\u003c\/a\u003e\u003ca title='3\/4\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_3_4__304_SS_ANSI_RFF_MAG_meter.pdf?v=1589319650\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e# Flang\u003c\/a\u003e\u003ca title='3\/4\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_3_4__304_SS_ANSI_RFF_MAG_meter.pdf?v=1589319650\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003ee MAG Meter Cut sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003cstrong\u003e\u003ca style=\"text-decoration: underline; color: #005fff;\" title='1 1\/2\" TriClover MAG Meter Cut Sheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/1_1_2__TriClover_MAG_meter_Dimensions.pdf?162\" target=\"_blank\"\u003e1 1\/2\" TriClover MAG Meter Cut Sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_1__304_SS_ANSI_RFF_MAG_meter.pdf?v=1613593059\" title='1\" MAG Meter Cut sheet. List Price $1,600' style=\"color: #005fff;\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan color=\"#2b00ff\"\u003e1\" ANSI Raised Face 150# Flange MAG Meter Cut sheet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_1__304_SS_ANSI_RFF_MAG_meter.pdf?v=1613593059\" title='1\" MAG Meter Cut sheet. List Price $1,600' style=\"color: #005fff;\" target=\"_blank\"\u003e \u003cspan style=\"text-decoration: underline;\"\u003e \u003c\/span\u003e \u003c\/a\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_2__304_SS_150_ANSI_RFF_MAG_meter.pdf?v=1613593391\" title='2\" ANSI Raised Face Flange MAG meter specifications and dimensions' style=\"color: #005fff;\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan\u003e\u003cstrong\u003e2\u003cspan color=\"#2b00ff\"\u003e\" ANSI Raised Face 150# Flange MAG Meter Cut sheet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003cstrong\u003e\u003ca style=\"text-decoration: underline; color: #005fff;\" title='2\" TriClover MAG Meter Cut Sheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/2__TriClover_MAG_meter_Dimensions.pdf?162\" target=\"_blank\"\u003e2\" TriClover MAG Meter Cut \u003c\/a\u003e\u003ca title='2\" TriClover MAG Meter Cut Sheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/2__TriClover_MAG_meter_Dimensions.pdf?162\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003eSheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003ca title='2\" Remote Mount MAG Meter 150# ANSI Flange' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_2__304_SS_150_ANSI_RFF_Remote_MAG_meter.pdf?v=1588811838\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e\u003cstrong\u003e2\" 304 SS ANSI 150# RFF Remote MAG meter CutSheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003ca title=\"Ceramic Al2Oc Wafer Mount MAG Meter Cut Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_Ceramic_Wafer_MAG_Meter.pdf?v=1602534497\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e\u003cstrong\u003eCeramic, Al2O3, Wafer Mount MAG Meter CutSheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003ca title=\"Battery Powered MAG Meter Cut Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Battery_Powered_MAG_meter_Cut_Sheet_Rev_2.pdf?208\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e\u003cstrong\u003eBattery Powered MAG Meter Cut Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003e\u003ca style=\"color: #2b00ff;\" title=\"3D STEP Files for MAG Meter, Copyrighted 2020 TacticalFlowMeter.com\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAGMeterSTEP-TacticalFlowMeterCopyright-2020.zip?v=1588812413\" target=\"_blank\"\u003eLink to Copyrighted 3D STEP Files\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003e\u003cspan style=\"background-color: #ffff00;\"\u003e\u003c\/span\u003e \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Power_Supplies_Bolts_Gaskets_and_more.pdf?v=1605288973\" title=\"Where to get 24 VDC Power Supplies and flange bolts and gaskets\" style=\"color: #2b00ff; text-decoration: underline;\" target=\"_blank\"\u003eWhere to get Power Supplies, Gaskets, Nuts and Bolts\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e \u003ca title=\"MAG Meter Fluid Conductivity Chart in µS\/CM\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/CONDUCTIVITY_CHART_MAG_METER.pdf?v=1606413904\" style=\"color: #2b00ff; text-decoration: underline;\" target=\"_blank\"\u003eMAG Meter Conductivity chart for various fluids\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eRefer to this chart to ensure your fluid has sufficient conductivity to honor Faraday's Law that is the essence of the MAG Meter.\u003c\/p\u003e\n\u003ch5\u003e \u003cstrong\u003eTheory\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003ch2\u003eMAG Meter Theory and Wiring \u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG_Meter_Wiring.png?v=1590102436\" alt=\"MAG Meter Theory and Wiring\" loading=\"lazy\"\u003e\n\u003c\/h2\u003e\n\u003cp\u003eAs an electrically conductive fluid flow passes through the magnetic field in a MAG meter the electrically charged ions accumulate, with negative ions on one side and positive ions on the other.  (Note the MAG meter actually flips the polarity of the magnetic field quickly and the ions move at the speed of light and allow easy measurement) The resulting change in voltage is directly proportional to the velocity of the fluid passing through the inside diameter of the MAG meter. This velocity is used to convert the flow to the flowing volume, usually GPM knowing the measured fluid velocity and the internal pipe diameter.\u003cbr\u003e\u003cbr\u003eInsertion MAG meters utilize a small, localized \"probe\" with magnetic field that is inserted into the pipe. Electrodes cause the positive and negative ions to separate as they do in an inline flow MAG meter. Insertion MAG meters have electrodes located along the probe length to measure average velocity in the measuring location.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003eBattery Powered MAG Meter Specifications\u003c\/strong\u003e \u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Battery_Powered_MAG_Meter_Specifications.png?v=1573189176\" alt=\"Battery Powered MAG Meter Basic Specifications\" loading=\"lazy\"\u003e\n\u003c\/h2\u003e\n\u003cp\u003eIdeally suited for Irrigation MAG meters and Irrigation Flow Meters as they are battery powered.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e4-20 mA Connection to Battery Powered MAG meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch4\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/BatteryPowered_MAG_Meter_4-20_mA_Connection.png?v=1593707853\" alt=\"Battery Powered MAG Meter 4-20 mA connection (Sink mode)\" loading=\"lazy\"\u003e\u003c\/h4\u003e\n\u003ch5\u003e\u003cstrong\u003eVideos\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch4\u003eBattery Powered MAG Meter User instruction video overview:\u003c\/h4\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"Xr9zAc3Tbp4\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/Xr9zAc3Tbp4\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Battery_Powered_MAG_meter_Cut_Sheet_Rev_2.pdf?208\" title=\"Battery Powered MAG Meter Cut Sheet\" target=\"_blank\"\u003e\u003cspan\u003e\u003cstrong\u003eBattery Powered MAG Meter Cut Sheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eMAG Meter Grounding Ring Sets\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.tacticalflowmeter.com\/products\/grounding-rings-for-mag-meters\" title=\"MAG Meter Grounding Rings\" target=\"_blank\"\u003eVisit Grounding Ring page\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"YL4dhSvo9OQ\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/YL4dhSvo9OQ\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eQuick video above showing how to use the front panel buttons. The SECRET password to CHANGE variables is 03210 where 00521 is for VIEWING only. To get back to NORMAL operation hold the Enter button (the rightmost button) for 3 to 5 seconds. Password to Configure Calibration is 19818\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"_ynfjjTGYbg\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/_ynfjjTGYbg\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eVideo above shows how to set up the Flow Units and Full Scale for those units. Note that this scaling is for driving the 4-20 mA and the frequency output so that the Full Scale value at 20 mA and at full scale Frequency is the number that is set. In this case the 4-20 and the frequency will output 20 mA and 5,000 Hz when the display shows 200 GPM. If the display goes OVER 200 GPM the 4-20 and the Frequency will increase until it \"bumps it's head\" on the maximum value. If the value on the display is GREATER than the value in Full Scale then one would adjust this value to accommodate the anticipated maximum value.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"c0hLnYA-8Qc\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/c0hLnYA-8Qc\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003eThe video above shows how to set up the meter for Pulse and Frequency and shows how the 4-20 mA is configured. Simulating and validating the 4-20 mA output using the User Interface with 03210 is detailed below. You may ALTER these values (AnalogZero and AnlgRange) using 03210 and they will revert when you exit. Note the 4-20 mA output for this meter is POWERED by the meter. DO NOT connect to a PLC that provides 24 VDC. Connection is made to the 4-20 mA signal using a reading mode just like a Fluke Meter configured to read 4-20 mA DC. The MAG meter provides the 24 VDC for outputting the value to the INPUT of your PLC. Every PLC has the ability to be configured to read this type of 4-20 mA output. (Note: From the main menu the AnalogZero is 49 hits of the UP arrow.) (ADJUSTMENT of the 4-20 Output drive is attained using secret password of 19818 and is risky to use.) \u003cstrong\u003eIf the meter indicates a NEGATIVE flow you may REVERSE the flow using Menu 8: Flow Direction and change it from the indicated value to either the REVERSE or FORWARD value.\u003c\/strong\u003e Note: If the flow indicates a NEGATIVE FLOW number AND you know it is going from LEFT to RIGHT Menu 8 may be used to FLIP the sign. The Flow Direct is a \"switch\" to take care of the \"Right Hand Rule\" with regards to the direction of the current vector in Faraday's Law and does not require the direction to agree with the arrow on the meter. \u003cstrong\u003eIf the meter indicates a  NEGATIVE flow on the display and does not output 4-20 mA it means that  Menu 13: SigmaN Ena can be set to ENABLE to allow the 4-20 to indicate flow in both the + and negative direction. Set Menu 13: SigmaN Ena to DISABLE if you do not want flow to indicate if the flow reverses. In this case the mA will go to 0 mA to indicate reverse flow, but not the magnitude in rate. However, the NEGATIVE Totalizer will account for the negative flow.\u003c\/strong\u003e \u003cstrong\u003eSee video below:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"yK618Tt-ez4\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/yK618Tt-ez4\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eIMPORTANT NOTE:\u003c\/strong\u003e \u003cstrong\u003eThis meter is not a \"Loop Powered\" device, unlike almost all temperature and pressure transducers that are loop powered. This meter takes 500 mA to run so you can see that they can not be Loop Powered. It is CRITICAL that 24 VDC is NOT connected to the 4-20 mA signal lines of COM and I+ where COM is connected to the \"low\" side,-, of the 4-20 mA and the I+ is connected to the \"high\" side,+. Your PLC has a mode in it to read these meters that does NOT involve sending power to the meter. These meters are SOURCING the 24 VDC. Connecting 24 VDC to the Current Output lines may void warranty.\u003c\/strong\u003e The video below shows how to VALIDATE the 4-20 mA signal into your PLC or reading device. Note: If this DOES NOT WORK a likely cause is the power supply does not have enough \"power\" to provide to the meter. The meter requires a MAX of 500 mA so have a power supply that has the capability to DELIVER 500 mA, even on \"start up\" where the inrush current given to the electromagnetic coils can rush over 500mA for a few milliseconds. \u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"sJQ9CYjCwC0\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/sJQ9CYjCwC0\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003eHow to Reset the Totalizer in the MAG Meter. The Password to set the password for the totalizer reset is 10000.  We show Clr Sum Key as the 24'th element in the menu structure. The video shows how to set the Totalizer Reset password to 10000. \u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"pUti8oBQesQ\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/pUti8oBQesQ\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003eHow to use ModBusPoll on the TacticalFlowMeter MAG meter. Use this to ensure your configuration with your PLC is correct.\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"4lquEZuTjh0\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/4lquEZuTjh0\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eIf your flow meter is not showing flows at very low flows. You will use this if you notice the flow meter shows 0 flow when you know there is very low flow. The meter ALSO likely has the Response time set at 10 seconds so it suppresses very low flows further. Refer to \u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Mag-Meter-FlowRate-Chart-TacticalFlowMeter_0.3_to_12mps.png?v=1625240566\"\u003eTHIS chart to find the lowest readable flow on YOUR size flow meter\u003c\/a\u003e \u003c\/strong\u003e. \u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eHow to Set the Low Flow Cutoff on the Style 1 MAG meter\u003c\/h4\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"TJ4ieBJo4Sk\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/TJ4ieBJo4Sk\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eHow to Set the Low Flow Cutoff on the Style 2 MAG meter\u003c\/h4\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"22y4sgKYKh8\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/22y4sgKYKh8\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eStyle 2 MAG Meter Interface with 4-20 mA Diagnostics and wiring diagram information.\u003c\/h4\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"Ziu6P72Z-uE\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/Ziu6P72Z-uE\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eInsertion MAG Meter overview.\u003c\/h4\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"gdFMiz4bo20\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/gdFMiz4bo20\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eView video above to see how an INSERTION MAG meter is installed, which is DIFFERENT than the flange meters on this product page. Please visit \u003ca href=\"https:\/\/www.tacticalflowmeter.com\/collections\/magnetic-flow-meters\/products\/insertion-magnetic-flow-meter-1-0-accuracy\" title=\"Tactical Flow Meter, Insertion MAG Meter\" target=\"_blank\"\u003eINSERTION MAG\u003c\/a\u003e meter product listing if you discover you need an Insertion Mag Meter. Note: The following display orientations can be ordered so the user does not have to orient in the field.\u003c\/h4\u003e\n\u003cp\u003eLearn why Insertion meters only need to be inserted less than 5\" in larger pipes by watching the video below....\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"rk8rcwH5muM\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/rk8rcwH5muM\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eDiscover where the classical \"1\/8 D Insertion Depth\" for location of an insertion meter sensor comes from. We show fluid mechanics data showing WHY the guidance if the pipe Diameter is greater than 10\" the insertion depth only needs to be 5\"... An Approximation. Above we discuss the EXACT value required to follow \"\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Flow_Profile_From_Miller_Chapter_5.pdf?v=1605202101\" title=\"Mag Meter Insertion Depth at 1\/8th pipe Diameter\" target=\"_blank\"\u003eMiller Best Practices\u003c\/a\u003e\u003c\/strong\u003e\".\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"WZnWhWXi1f0\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/WZnWhWXi1f0\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eView video above to see examples of LabVIEW programs we supply to Universities and some customers to assist in getting their projects online.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"FWHHf9xGZnE\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/FWHHf9xGZnE\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eVideo above shows the MAG meter configuration program\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes a SYS error or SYS alarm on the MAG meter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSYS means there is a System alarm. The reasons for it may be from the following: \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e1. No water in the pipe line... or\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e2. pipe line is not 100% filled with water... or\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e3. The measuring electrodes are not covered by the water... or\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 4. The fluid\/water is too pure, the conductivity is less than 15 μs\/cm... or\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e5. Water has entered the sensor electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e Note: This alarm can be disabled (Menu 24) as there is no harm in running the meter with no fluid. The purpose of the alarm is to \"latch\" and show itself if any of the above instances may have occurred.\u003c\/p\u003e","brand":"Tactical Flow Meter","offers":[{"title":"1\/2\" \/ ANSI 150#","offer_id":41811540541609,"sku":"Mag-AN-1_2","price":1500.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ TriClover Sanitary","offer_id":41811540607145,"sku":"Mag-TC-1_2","price":1600.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ ANSI 150#","offer_id":41811540639913,"sku":"Mag-AN-1","price":1550.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ TriClover Sanitary","offer_id":41811540705449,"sku":"Mag-TC-1","price":1650.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ ANSI 150#","offer_id":44993676476585,"sku":"Mag-AN-1_1_2","price":1600.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ TriClover Sanitary","offer_id":44993676509353,"sku":"Mag-TC-1_1_2","price":1700.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ ANSI 150#","offer_id":41811540738217,"sku":"Mag-AN-2","price":1700.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ TriClover Sanitary","offer_id":41811540803753,"sku":"Mag-TC-2","price":1800.0,"currency_code":"USD","in_stock":true},{"title":"2 1\/2\" \/ ANSI 150#","offer_id":44993676542121,"sku":"Mag-AN-2_1_2","price":1750.0,"currency_code":"USD","in_stock":true},{"title":"2 1\/2\" \/ TriClover Sanitary","offer_id":44993676574889,"sku":"Mag-TC-2_1_2","price":1850.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ ANSI 150#","offer_id":41811540836521,"sku":"Mag-AN-3","price":1850.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ TriClover Sanitary","offer_id":41811540902057,"sku":"Mag-TC-3","price":1950.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ ANSI 150#","offer_id":41811540934825,"sku":"Mag-AN-4","price":1950.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ TriClover Sanitary","offer_id":41811541000361,"sku":"Mag-TC-4","price":2050.0,"currency_code":"USD","in_stock":true},{"title":"6\" ANSI ONLY \/ ANSI 150#","offer_id":41811541033129,"sku":"Mag-AN-6","price":2300.0,"currency_code":"USD","in_stock":true},{"title":"8\" ANSI ONLY \/ ANSI 150#","offer_id":41811541098665,"sku":"Mag-AN-8","price":2700.0,"currency_code":"USD","in_stock":true},{"title":"10\" ANSI ONLY \/ ANSI 150#","offer_id":41811541164201,"sku":"Mag-AN-10","price":3650.0,"currency_code":"USD","in_stock":true},{"title":"12\" ANSI ONLY \/ ANSI 150#","offer_id":41811541229737,"sku":"Mag-AN-12","price":4750.0,"currency_code":"USD","in_stock":true},{"title":"6\" and up Insertion +\/- 1.0% \/ ANSI 150#","offer_id":46413680148649,"sku":"Mag-Insertion-1_0-1","price":3600.0,"currency_code":"USD","in_stock":true},{"title":"6\" to 96\" Insertion +\/- 2.0% \/ ANSI 150#","offer_id":46413154517161,"sku":"Mag-Insertion-2_0-1","price":3300.0,"currency_code":"USD","in_stock":true},{"title":"6\" to 96\" Insertion +\/- 2.0% with High Pressure Retractor \/ ANSI 150#","offer_id":46413234045097,"sku":"Mag-Insertion-Retractor-2_0-1","price":4800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG-Meter-TacticalFlowMeter.webp?v=1758754506","url":"https:\/\/www.tacticalflowmeter.com\/products\/magnetic-flow-meter","provider":"Tactical Flow Meter","version":"1.0","type":"link"}