{"product_id":"insertion-magnetic-flow-meter-1-0-accuracy","title":"Insertion Magnetic Flow Meter \u003cbr\u003efor Liquid Flow \u003cbr\u003e6\" and up \u003cbr\u003e+\/- 1.0%","description":"\u003cp\u003eInsertion MAG Flow Meter with or without High Pressure Retractor. Select the option you require.\u003c\/p\u003e\n\u003cp\u003eThe TFM Insertion Mag Meter operates based on Faraday’s Law of electromagnetic induction: as flow velocity of a liquid increases through the magnetic field generated by the sensor head of the flow meter, electrodes measure the voltage increase to calculate flow. … The voltage readings are sampled \u0026amp; averaged.\u003c\/p\u003e\n\u003cp\u003eInsertion Mag meter for liquids, slurries shipping from stock \u0026amp; configured for you.\u003c\/p\u003e\n\u003cp\u003eEASY to use Insertion MAG Meters. Check our stock and prices that beats our competition.\u003c\/p\u003e\n\u003cp\u003e\u003c!--split--\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv class=\"product-bullet-list\"\u003e\n\u003cul\u003e\n\u003cli\u003eWetted Materials: Teflon \u0026amp; 316 SS\u003c\/li\u003e\n\u003cli\u003eFlow Body Material: 304 SS\u003c\/li\u003e\n\u003cli\u003eFlow Rate: 100 kg\/h to 200,000 kg\/h relative to water\u003c\/li\u003e\n\u003cli\u003eAccuracy:\n\u003cul\u003e\n\u003cli\u003e+\/- 1.0% of reading in water.\u003c\/li\u003e\n\u003cli\u003eLowest measuring velocity is 0.5 m\/s, or 100 fpm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eRepeatability of +\/- 0.05% of reading\u003c\/li\u003e\n\u003cli\u003ePipe Size:\n\u003cul\u003e\n\u003cli\u003eInsertion for 6\" to 100\" Diameter pipe\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLCD Display\u003c\/li\u003e\n\u003cli\u003eTemperature:\n\u003cul\u003e\n\u003cli\u003eGas: -58°F (-50°C) to 350°F (180°C)\u003c\/li\u003e\n\u003cli\u003eAmbient: 14°F (-10°C) to 140°F (60°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Requirement: Order either 24 VDC or 85-220 VAC, 15 Watts maximum;\u003c\/li\u003e\n\u003cli\u003eOutput signals: Modbus RTU, 4–20 mA, and 0-10 KHz for flow rate indication\u003c\/li\u003e\n\u003cli\u003eDigital communications: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eProof Pressure: 230 PSIG, 1.6 MPa.\u003c\/li\u003e\n\u003cli\u003eDisplay: Flow rate, Flow Rate 0-100%, and Total flow\u003c\/li\u003e\n\u003cli\u003eWiring connection to enclosure size: M20 x 1.5\u003c\/li\u003e\n\u003cli\u003eFactory Final QC Test Certificate\u003c\/li\u003e\n\u003cli\u003eIntegral Electronics installation\u003c\/li\u003e\n\u003cli\u003eElectronics Enclosure: NEMA 4X \/ IP67\u003c\/li\u003e\n\u003cli\u003eConductivity \u0026gt; 5 microSiemens\/cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003e\u003ca title=\"In Stock MAG Meters low price\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters.pdf?5036035778741373374\" target=\"_blank\"\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Mag-Meter-Product-Overview.png?v=1543259636\" alt=\"Mag Meter Product Overview\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eFlow Range\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eThe image below gives a guideline of the nominal maximum GPM for various pipe sizes \u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/GPM-FlowRates.jpg?v=1544056504\" alt=\"Pipe sizes versus GPM guidelines\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG-Meter-Display-Description.png?v=1529382214\" alt=\"MAG Flow Meter Display\" loading=\"lazy\"\u003e\u003cbr\u003eFeatures LARGE LCD display, shows the Instantaneous Flow Rate, Total Flow, in user selectable units.\u003c\/p\u003e\n\u003cp\u003eWhere to get Power Supplies, Gaskets, Nuts and Bolts \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Power_Supplies_Bolts_Gaskets_and_more.pdf?v=1605288973\" title=\"Where to get 24 VDC Power Supplies and flange bolts and gaskets\" target=\"_blank\"\u003eLink\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eNote: The following display orientations can be ordered so the user does not have to orient in the field.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Flow_Meter_Display_DIrection_Guide_R1.png?v=1607378321\" alt=\"MAG Meter flow Orientation guide\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eRetractor\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eHIGH PRESSURE  INSERTION FLOW METER RETRACTOR\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/INSERTION_METER_WITH_RETRACTOR.png?v=1662351244\" alt=\"Insertion Meter with Retractor\" loading=\"lazy\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch3 class=\"title style-scope ytd-video-primary-info-renderer\"\u003eFlowmeter Retractor \u0026amp; Hot Tap Insertion Meter Retractor\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe HIGH PRESSURE RETRACTOR works with the INSERTION MAG METER or the INSERTION VORTEX METER.  It is smooth as silk and super strong (2,000 PSIG max).  The flexible design will work well with all brands of insertion flow meters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb\u003eHigh Pressure Retractor Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Overall dimensions:  33.5” x 10.8” x 5.6”\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Anodized aluminum brackets and shear box\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Held together with 304 SS hardware\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Smooth 304 SS  ACME screw drive\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e 304 SS guide rails and bearings for increased load capacity\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Power drill actuated - articulation from 0-27 inches\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e 5\/16” hex driver bit included.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eConsult factory for custom installation drawings for your Insertion MAG Meter requirements.\u003c\/p\u003e\n\u003ch3\u003eINSERTION MAG Meter Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/InsertionDepth.jpg?v=1565382278\" alt=\"Insertion Depth\" loading=\"lazy\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/InsertionSideView.jpg?v=1565382292\" alt=\"Insertion Side View\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/Insertion_Dimensions.jpg?v=1565382304\" alt=\"Insertion Dimensions\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003eNote: The image above allows one to determine the Hot Tap or Corp. Stop, Corporation Stop, requirements ad the 3.4\" long \"sensing region\" can be retracted within the 7.0\" long tube that is shown BELOW the Ball Valve in the above image. Frequently, customers utilize their own Ball Valve left behind from the Hot Tap or Corp. Stop rig that drilled into the \"live\" pipe. It is VERY important to note that the sensing point only needs to be inserted 1\/8'th of the diameter into the flowing stream, IDEALLY, from the SIDE rather than the Top of Bottom as the Bottom is the least ideal location due to buildup. See the Fluid Mechanics video and paper BELOW explaining WHY this is true.\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"MAG Meter dimensions and installation requirements\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R2.pdf?172\" target=\"_blank\"\u003eMAG Meter dimensions\/ Installation requirements\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003ePlumbing\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eInsertion and Flanged MAG Meter Installation requirements:\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"MAG meter plumbing requirements\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters.pdf?5036035778741373374\" target=\"_blank\"\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG-Meter-Plumbing-Requirements-1.png?v=1543277467\" alt=\"Mag Meter Plumbing Requirements\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eCut Sheet\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003ca title='6\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/6__ANSI_RFF_MAG_meter.pdf?788851432150458519\" target=\"_blank\"\u003e6\" ANSI Raised Face Flange MAG Meter Cut sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eVideos\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv class=\"tab\" id=\"tab-5\"\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv data-id=\"YuhwixeAP14\" class=\"youtube-lite\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg loading=\"lazy\" alt=\"Video Thumbnail\" data-base=\"https:\/\/img.youtube.com\/vi\/YuhwixeAP14\/hqdefault.jpg\" class=\"responsive-content-image\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv data-id=\"YL4dhSvo9OQ\" class=\"youtube-lite\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg loading=\"lazy\" alt=\"Video Thumbnail\" data-base=\"https:\/\/img.youtube.com\/vi\/YL4dhSvo9OQ\/hqdefault.jpg\" class=\"responsive-content-image\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eQuick video showing how to use the front panel buttons.\u003c\/p\u003e\n\u003cp\u003eLearn why Insertion meters only need to be inserted less than 5\" in larger pipes by watching the video below....\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv data-id=\"rk8rcwH5muM\" class=\"youtube-lite\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg loading=\"lazy\" alt=\"Video Thumbnail\" data-base=\"https:\/\/img.youtube.com\/vi\/rk8rcwH5muM\/hqdefault.jpg\" class=\"responsive-content-image\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eDiscover where the classical \"1\/8 D Insertion Depth\" for location of an insertion meter sensor comes from. We show fluid mechanics data showing WHY the guidance if the pipe Diameter is greater than 10\" the insertion depth only needs to be 5\"... An Approximation. Above we discuss the EXACT value required to follow \"\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Flow_Profile_From_Miller_Chapter_5.pdf?v=1605202101\" title=\"Mag Meter Insertion Depth at 1\/8th pipe Diameter\" target=\"_blank\"\u003eMiller Best Practices\u003c\/a\u003e\u003c\/strong\u003e\".\u003c\/p\u003e\n\u003cp\u003e\u003c\/p\u003e\n\u003cdiv data-id=\"gdFMiz4bo20\" class=\"youtube-lite\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg loading=\"lazy\" alt=\"Video Thumbnail\" data-base=\"https:\/\/img.youtube.com\/vi\/gdFMiz4bo20\/hqdefault.jpg\" class=\"responsive-content-image\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eView video above to see how an INSERTION MAG meter is installed, which is DIFFERENT than conventional flange meters. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tactical Flow Meter","offers":[{"title":"Default Title","offer_id":46413642236073,"sku":"Mag-Insertion-1-1","price":3600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM_Mag_Insertion2_Front.webp?v=1758815768","url":"https:\/\/www.tacticalflowmeter.com\/products\/insertion-magnetic-flow-meter-1-0-accuracy","provider":"Tactical Flow Meter","version":"1.0","type":"link"}