{"product_id":"inline-ultrasonic-flow-meter","title":"Inline Ultrasonic Flow Meter \u003cbr\u003efor Liquid Flow \u003cbr\u003e1\/2\" to 6\"","description":"\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eInline ultrasonic flow meters use sound waves transmitted through the fluid to measure flow rate directly in a fixed pipe section. They offer high accuracy, low pressure drop, and no moving parts, making them ideal for clean liquids. Benefits include minimal maintenance, excellent long-term stability, and suitability for sanitary or corrosive environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eInline ultrasonic flow meters work well in challenging applications like flare gas, where traditional meters struggle due to variable flow rates, changing gas composition, and low pressures. They're also effective in custody transfer of natural gas, process control in petrochemical plants, and compressed air systems. Their non-intrusive measurement and ability to handle wide turndown ratios make them ideal for leak detection, waste gas monitoring, and low-flow vapor measurement, especially in harsh or hazardous environments. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eInline Ultrasonic Flow Meters at the prices of High-End Clamp On Ultrasonic Flow Meters and feature accuracies of 0.5% of READING. Ideal for DI Water and many fluids that the MAG meter can not measure due to low electrical conductivity. Perfect for oils such as Diesel Oil and many other oils.\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFeatures LARGE LCD display, shows the Instantaneous Flow Rate, Total Flow, in user selectable units.\u003c\/b\u003e \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!--split--\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch6 style=\"font-size: 1.17em; font-weight: bold; margin: 1em 0;\"\u003eInline Ultrasonic Flow Meter Specifications\u003c\/h6\u003e\n\u003cdiv class=\"product-bullet-list\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFlow Body material: 304 SS\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMedium: Any acoustically conductive liquid with less than 5% air bubbles or solids \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlow Range: Supports velocities up to  40 f\/s or 12 m\/s \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAccuracy: ±1% from 0.15 to 40 f\/s (0.05 to 12 m\/s)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResolution: 0.01 ft\/s (0.00025 m\/s)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eResponse time: 150 ms measuring cycle typical\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePipe size: 1” to 6”, custom up to 12\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eTemperature: - 20 - 110 ℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTransducer Frequency: 1 MHz\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eStd Temp Spec for Transmitters: 320 F (160 C)\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnclosure Grade: IP65\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDisplay LCD Screen\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower Supply: Set up to use either 24VDC or a 86-240 VAC Universal Power Supply. Only one at a time. Consumes 500 mA max\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOutput: 4-20mA + 0-10K Hz + Standard ModBus RTU Communication protocol\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNote: For 1 to 5 VDC output, add 250 Ohm resistor to 4 to 20 mA loop\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eInstructions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003e\u003ca title=\"Inline Ultrasonic Flow Meter Quick User Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Inline_Ultrasonic_user_manual_R-1d.pdf?v=1638580629\"\u003eTFM Inline Ultrasonic Manual\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Quick_ultrasonic_flow_meter_Style_2_user_Manual_R16.pdf?v=1591375140\" title=\"Ultrasonic Flow Meter Quick User Manual\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch5\u003e\u003cstrong\u003eFlow Rates\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eInline Ultrasonic flow meters (Ultrasonic flow meters) are volumetric flow meters for measuring acoustically conductive fluids [Not Gases] that operate without any moving parts and are ideal for potable water and wastewater applications as well as ideal for any non conductive or water based clean or dirty fluid.  Ultrasonic flow meters will work with hydrocarbons, distilled water, DI water, and many non-aqueous solutions where the MAG meter is not capable or performing.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe table below gives a guideline of the nominal maximum GPM for various pipe sizes. \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eFlows in well designed piping systems, to minimize wear and noise, and energy, are typically no more than 10 m\/s max.\u003c\/strong\u003e\u003c\/span\u003e Note these meters can easily go to 12 m\/s for systems, such as high pressure fire fighting systems and blowdown systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg loading=\"lazy\" alt=\"Ultrasonic Flow Meter Flow Rate Chart\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Mag-Meter-FlowRate-Chart-TacticalFlowMeter_0.3_to_12mps_d1d83023-3dcd-43f7-b0f4-529eafcf46c4.png\" class=\"responsive-content-image\"\u003e\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eCut Sheet\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_Ultrasonic_Flow_Meter_R0.pdf?v=1595279214\" title=\"Ultrasonic Cut Sheet\" target=\"_blank\"\u003eUltrasonic Cut Sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch5\u003e\u003cstrong\u003eCheat Sheet\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003e\n\u003ca title=\"Ultrasonic Installing Cheat Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Inline_Ultrasonic_user_manual_R-1c_e3682a6c-a9a2-4182-a15a-3156ce5fc4a7.pdf?v=1638579927\" target=\"_blank\"\u003eUltrasonic Installing Cheat Sheet\u003c\/a\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\u003c\/ul\u003e\n\u003ch5\u003e\u003cstrong\u003eQuick Notes\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cstrong\u003eHELPFUL QUICK NOTES: Menu 90 shows Signal Strength and Menu 00 shows main flow rate and total.\u003c\/strong\u003e  Also set menu 40, the Filter Coefficient, (We could call this the time constant or response time), with Menu 40 to 1 second to make the meter respond quickly. Then, put back to 4 seconds and save with Menu 26 and hit enter twice. Menu 45 is for entering a K-Factor, this would be handy if you KNOW the flow is 90 when it says 100. In this case a K-Factor of 0.9 would remedy it. (Ideally the distances and pipe thickness\/material would be corrected but this is easier). Menu 70 and 71 allow LCD Display on time and contrast respectively\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e§3.1.6 Validating meter function.\u003c\/strong\u003e\u003cbr\u003eEntering a pipe outer diameter (Menu 11) of zero, results in the display to show the flow velocity: 1.2345678m\/s (4.0504ft\/s) [use down arrow to view], flow rate= will vary, and display “R”status on Menu 00. Inputting a set value in M44 will change the totalizer output. Use this function to test of the flow meter and network software without having to connect the transducers. If they are connected the flow rate may be + or -\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch2 style=\"text-align: left;\"\u003eInline Ultrasonic Meter Dimensions\u003ca title='1\/2\" to 12\" MAG Meter Dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R4.pdf?v=1588134523\"\u003e\u003cimg loading=\"lazy\" alt='1\/2\" to 12\" MAG Meter Dimensions' data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MagMeterDimensions1Inch_to_12_Inch.png\" class=\"responsive-content-image\"\u003e\u003c\/a\u003e\n\u003c\/h2\u003e\n\u003ch5 style=\"text-align: left;\"\u003e\u003cstrong\u003ePlumbing\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R2.pdf?172\" title=\"MAG Meter dimensions and installation requirements\" target=\"_blank\"\u003eMAG Meter dimensions\/ Installation requirements\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003eFlow Meter Installation requirements:\u003c\/p\u003e\n\u003cp\u003eThe video above shows how to set up the meter for Pulse and Frequency and shows how the 4-20 mA is configured. \u003c\/p\u003e\n\u003cp\u003eSimulating and validating the 4-20 mA output using the User Interface with 03210 is detailed below. You may ALTER these values (AnalogZero and AnlgRange) using 03210 and they will revert when you exit.\u003c\/p\u003e\n\u003cp\u003eNote the 4-20 mA output for this meter is POWERED by the meter. DO NOT connect to a PLC that provides 24 VDC. Connection is made to the 4-20 mA signal using a reading mode just like a Fluke Meter configured to read 4-20 mA DC. The MAG meter provides the 24 VDC for outputting the value to the INPUT of your PLC. Every PLC has the ability to be configured to read this type of 4-20 mA output. (Note: From the main menu the AnalogZero is 49 hits of the UP arrow.) (ADJUSTMENT of the 4-20 Output drive is attained using secret password of 19818 and is risky to use.)\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003cstrong\u003ePressure Ratings\u003c\/strong\u003e\u003ca title=\"Inline Ultrasonic-Meter-Quick-User-Manual-and-Wiring-Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Inline_Ultrasonic_user_manual_R-1d.pdf?v=1638580629\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/h5\u003e\n\u003ch3\u003eFlange Pressure Ratings Chart:\u003c\/h3\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" alt=\"ANSI Class Rating Chart from Class 150 to Class 2500\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/ANSI_CLASS_Flange_Pressure_Ratings_Chart.png\" class=\"responsive-content-image\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eSpeed of Sound\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch2\u003eUltrasonic Flow Meter Sound Speed for various fluids.\u003c\/h2\u003e\n\u003cp\u003eRefer to this chart to ensure your fluid has sufficient conductivity to honor Faraday's Law that is the essence of the MAG Meter\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/SoundSpeedMaterials.png?3247770073703420262\" title=\"Sound Speed of Various Materials\" target=\"_blank\"\u003e\u003cimg loading=\"lazy\" alt=\"Sound Speed Various Materials\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/SoundSpeedMaterials.png\" class=\"responsive-content-image\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eTheory\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch2\u003eUltrasonic Flow Meter Theory and Wiring \u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Flow_Sensor_Principle_Simplified_R2.pdf?v=1663606812\" title=\"PDF Theory of How Ultrasonic Flow Meters Work\"\u003e Theory of Ultrasonic Flow Meters PDF\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eVideos\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e \u003cstrong\u003eSee videos below:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe videos peertain top the Clamp on Ultrasonic as well as the inline ultrasonic as they use the smae \"engine\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003e\u003cstrong\u003eHELPFUL QUICK NOTES: Menu 90 shows Signal Strength and Menu 00 shows main flow rate and total. \u003c\/strong\u003eMenu 40, the Filter Coefficient, (We could call this the time constant or response time), with Menu 40 to 1 second to make the meter respond quickly. Then, put back to 4 seconds and save with Menu 26 and hit enter twice. Menu 45 is for entering a K-Factor, this would be handy if you KNOW the flow is 90 when it says 100. In this case a K-Factor of 0.9 would remedy it. (Ideally the distances and pipe thickness\/material would be corrected but this is easier). Menu 70 and 71 allow LCD Display on time and contrast respectively. Note for Password Menu 47 System Lock unlock code is 8758 \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003ePASSWORD = 8758\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003eK-Factor\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003eThere is a Scale or K-Factor at Menu 45 that you may wish to invoke if you know a flow to be 1.10 units and we say is is 1.00 units then you can adjust Menu 45 to 1.1 to have the meter agree with a standard you believe to be true and correct. After setting this value invoke Menu 25 with two Enter hits and then get back to the main menu with menu 00. Note: The Scale, or K-Factor can go from 0.5 to 1.5.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003e\u003c\/span\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eReset totalizers with Menu 37\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003e§3.1.6 Validating meter function.\u003c\/strong\u003e\u003cbr\u003eEntering a pipe outer diameter (Menu 11) of zero, results in the display to show the flow velocity: 1.2345678m\/s (4.0504ft\/s) [use down arrow to view], flow rate= will vary, and display “R” status on Menu 00. Inputting a set value in M44 will change the flow rate output. Use this function to test of the flow meter and network software without having to connect the transducers. If they are connected the flow rate may be + or - \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003eNote: Menu 44 allows setting up a ZERO value so that you can simulate flow. Entering a - (negative) value allows the flow to indicate positive. Be sure to put Menu 44 back to 0 when done simulating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSimple Overview how Ultrasonic Flow Meters Work. See the PDF below as well.\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Flow_Sensor_Principle_Simplified_R2.pdf?v=1663606812\" title=\"PDF of How Ultrasonic Flow Meters Work\"\u003ePDF of How Ultrasonic Flow Meters Work\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"UtgkIFGB358\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/UtgkIFGB358\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eSuper Simple example for parsing data from ModBus showing a fixed value and a changing value.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"WURWJ3lkDQQ\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/WURWJ3lkDQQ\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eUltrasonic Meter setup verification and overview of menus for \u003cstrong\u003eDOSING\u003c\/strong\u003e or \u003cstrong\u003eMETERING\u003c\/strong\u003e functions. The video below called \"\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eVideo showing How to connect 4-20 mA on the Ultrasonic Flow Meter\u003c\/strong\u003e\" shows more details about pipe type and fluid selection in the 4-20 mA. Please watch this quick video and do not forget about Menu 26.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"1LRB8Lk5WYc\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/1LRB8Lk5WYc\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eHow to make a Batch Controller with an Ultrasonic Flow Meter:\u003cbr\u003eNote: Menu 78 allows you to select the OCT (Open Collector Transistor) and\/or the Relay Output contact closure at pins 30 and 31 under menu 79 \u003cstrong\u003eRELAY Output Setup.\u003c\/strong\u003e Use selection \u003cstrong\u003e21: Batch Total Full.\u003c\/strong\u003e Remember: Select Menu 26 and hit ENT TWICE after making changes to SAVE your settings.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"pKgFyOrjLuo\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/pKgFyOrjLuo\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eVideo showing How to connect 4-20 mA on the Ultrasonic Flow Meter\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"DGmE37iVNCA\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/DGmE37iVNCA\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cimg loading=\"lazy\" alt=\"Ultrasonic Flow Meter Wiring for 4-20 mA output\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Flow_Meter_Wiring_4-20_mA.png\" class=\"responsive-content-image\"\u003e\u003c\/p\u003e\n\u003cp\u003eHow to Factory Reset the Meter Values if you discover unknown variables were changed. Note: Doing so retains the timing calibration elements but reverts to factory values that require selecting the language, units, transducer type, and all the pipe and fluid settings. We show this using Menu 37 twice, once to reset and the next to select the language, and then using Menu 30 to select the units, then 23 for the transducer type, then 70 to have the LCD Backlight stay on 999 seconds, and then on to menu 11 and the associated menus such as 77, we do not show menu 55 and associated menus for the 4-20 output. Remember Menu 26 TWICE to save your changes. Use the \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Meter_Setup_Cheat_Sheet_Rev_7.pdf?v=1613684951\" title=\"Cheat Sheet\" target=\"_blank\"\u003eCheat Sheet\u003c\/a\u003e to configure your meter as required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"V4mYT-MHojM\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/V4mYT-MHojM\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003e\u003cspan style=\"background-color: #ffff00;\"\u003eWhere to get Power Supplies, Gaskets, Nuts and Bolts\u003c\/span\u003e \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff; text-decoration: underline;\" title=\"Where to get 24 VDC Power Supplies and flange bolts and gaskets\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Power_Supplies_Bolts_Gaskets_and_more.pdf?v=1605288973\" target=\"_blank\"\u003eLink\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Tactical Flow Meter","offers":[{"title":"1\/2\" \/ ANSI","offer_id":43685480497321,"sku":"UltraI-AN-1_2","price":2000.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ TriClover","offer_id":43685480530089,"sku":"UltraI-TC-1_2","price":2100.0,"currency_code":"USD","in_stock":true},{"title":"3\/4\" \/ ANSI","offer_id":43685480562857,"sku":"UltraI-AN-3_4","price":2010.0,"currency_code":"USD","in_stock":true},{"title":"3\/4\" \/ TriClover","offer_id":43685480595625,"sku":"UltraI-TC-3_4","price":2110.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ ANSI","offer_id":41677532201129,"sku":"UltraI-AN-1","price":2020.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ TriClover","offer_id":41678119076009,"sku":"UltraI-TC-1","price":2120.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ ANSI","offer_id":41677532233897,"sku":"UltraI-AN-1_1_2","price":2300.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ TriClover","offer_id":41678119108777,"sku":"UltraI-TC-1_1_2","price":2400.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ ANSI","offer_id":41677532266665,"sku":"UltraI-AN-2","price":2200.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ TriClover","offer_id":41678119141545,"sku":"UltraI-TC-2","price":2300.0,"currency_code":"USD","in_stock":true},{"title":"2 1\/2\" \/ ANSI","offer_id":41677532299433,"sku":"UltraI-AN-2_1_2","price":2300.0,"currency_code":"USD","in_stock":true},{"title":"2 1\/2\" \/ TriClover","offer_id":41678119174313,"sku":"UltraI-TC-2_1_2","price":2400.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ ANSI","offer_id":41677532332201,"sku":"UltraI-AN-3","price":2500.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ TriClover","offer_id":41678119207081,"sku":"UltraI-TC-3","price":2600.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ ANSI","offer_id":41677532364969,"sku":"UltraI-AN-4","price":2600.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ TriClover","offer_id":41678119239849,"sku":"UltraI-TC-4","price":2700.0,"currency_code":"USD","in_stock":true},{"title":"6\" \/ ANSI","offer_id":41677532397737,"sku":"UltraI-AN-6","price":3600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/304SSInlineUltrasonicLogo.webp?v=1758048168","url":"https:\/\/www.tacticalflowmeter.com\/products\/inline-ultrasonic-flow-meter","provider":"Tactical Flow Meter","version":"1.0","type":"link"}