{"title":"1\"  and 2\" Tactical Flow Meter","description":"\u003cp\u003e1\" NPT 0-15 SCFM (25 SM3\/Hr) and Temperature\u003c\/p\u003e\n\u003cp\u003e4-20 mA AND 0-5 VDC\u003c\/p\u003e\n\u003cp\u003eTotalizer\u003c\/p\u003e\n\u003cp\u003eDatalogger\u003c\/p\u003e\n\u003cp\u003eBluetooth (Smart Phone App)\u003c\/p\u003e\n\u003cp\u003eModBus\u003c\/p\u003e\n\u003cp\u003eUSB\u003c\/p\u003e\n\u003cp\u003ePulse Output\u003c\/p\u003e\n\u003cp\u003eOLED Display\u003c\/p\u003e","products":[{"product_id":"thermal-mass-flow-meter-controller","title":"Thermal Mass Flow Meter\/Controller \u003cbr\u003e for Gas Flow \u003cbr\u003e1\" to 2\"","description":"\u003cp\u003eOur thermal Mass Flow Meter or Controller is capable of providing direct measurement of mass flow, as opposed to most other methods that measure volumetric flow \u0026amp; require separate measurements for temperature \u0026amp; pressure in order to calculate density \u0026amp;, ultimately, the mass flow.\u003c\/p\u003e\n\u003cp\u003eWe also sell gas Mass flow Controllers built to measure air \u0026amp; gas. These flow meters shipping from stock (usually within 48hrs) \u0026amp; are configured for you.\u003c\/p\u003e\n\u003cp\u003eOur EASY to use gas Mass Flow Controllers are in stock at prices that beat our competition.\u003c\/p\u003e\n\u003c!--split--\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003eThermal Mass Flow Meter\/Controller Specifications\u003c\/h3\u003e\n\u003cdiv class=\"product-bullet-list\"\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eChoose Material 316 SS, 6061 T6 Aluminum or Nylon 6\/6\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eVery low pressure drop for Natural Gas Flow Measurement into boilers.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cspan style=\"font-weight: 400;\"\u003eChoose Air Flow ranges:\u003c\/span\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFor 1\":  0- 10, 15, and 0-20 SCFM. \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFor 2\":  0- 40, 50, 60, 70, 80 SCFM.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eCustom flows available, just note what you need.\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eAccuracy: +\/- 1% of reading plus +\/-0.5% of full scale\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eRepeatability of +\/- 0.2% of full scale\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e1” MNPT Pipe size\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eOLED Display\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eMeasures any inert gas and any non-condensing clean gas\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlammable gases: methane, propane, digester gas, natural gas\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e100:1 turndown\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cspan style=\"font-weight: 400;\"\u003eTemperature: \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e    \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e    \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e    \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e    \u003c\/span\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eGas: -40°F (-40°C) to 350°F (200°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cspan style=\"font-weight: 400;\"\u003eAmbient: -40° F to 120° F (-40° C to 50° C)\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e   \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cspan style=\"font-weight: 400;\"\u003e\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eSS \u0026amp; Aluminum Max Pressure 25 PSIG  \u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\n\u003cspan style=\"font-weight: 400;\"\u003eNylon 6\/6 Max Pressure 25 PSIG  \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e    \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e    \u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eAdjustable Response time from 0.1 to 6 seconds to achieve 63% of final value\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003ePower Requirement: 18 to 30 VDC (regulated), 125 mA maximum;   \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eWetted Materials: Nylon 6\/6, 6061T6 Aluminum, \u0026amp; 316 stainless-steel\u003cbr\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eOutput signals: Modbus RTU, USB-RS-232, 4–20 mA , 0–5 VDC, and User definable pulse output or frequency for totalized or flow rate indication\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eDigital communications solutions include: Modbus RTU, USB, \u0026amp; Bluetooth\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eIP66 Enclosure\u003cbr\u003e\u003cbr\u003e\u003ca title='1\"Tactical Flow Meter Brochure' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/1-InchMFM-Revh.pdf?281406721728263953\" target=\"_blank\"\u003eDownload Brochure\u003c\/a\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eInstructions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch5\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp style=\"text-align: left;\"\u003eThe Tactical Flow Meter boasts a power fail tolerant datalog storage system that is a significant improvement over conventional \"SD Card\" file storage\/file management systems.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eWhile both our datalog storage system and a conventional \"SD Card\" storage systems utilize flash storage technology our storage system concatenates each event or data at the end of the file using a simple pointer system where the pointers stored in EEPROM and the data is stored sequentially after the last event.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eIf the power goes out in the middle of a storage event in a conventional \"SD Card\" system and the entire file can be lost.  If a power outage occurs during the middle of writing an event in our storage system the worst case is corruption of a single event at most.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003eAgain, SD Card technology can lose an entire file while the Tactical Flow Meter datalog storage system would only lose a single event.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eVideos\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eThe video below shows how the Tactical Flow Meter works and what advantages it has over conventional Thermal Mass Flowmeters.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e \u003c\/p\u003e\n\u003cdiv data-id=\"oyFpEr75fb4\" class=\"youtube-lite\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg loading=\"lazy\" alt=\"Video Thumbnail\" src=\"https:\/\/img.youtube.com\/vi\/oyFpEr75fb4\/hqdefault.jpg\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Tactical Flow Meter","offers":[{"title":"1\" Mass Flow Meter \/ 316-Stainless Steel","offer_id":36353689033,"sku":"TFM1-SS-10","price":3100.0,"currency_code":"USD","in_stock":true},{"title":"1\" Mass Flow Meter \/ 6061 T6 Aluminum","offer_id":36354315145,"sku":"TFM1-AL-10","price":2900.0,"currency_code":"USD","in_stock":true},{"title":"1\" Mass Flow Meter \/ Nylon 6\/6","offer_id":36354315529,"sku":"TFM1-NY-10","price":2800.0,"currency_code":"USD","in_stock":true},{"title":"1\" Mass Flow Controller \/ 316-Stainless Steel","offer_id":46314358603945,"sku":null,"price":4195.0,"currency_code":"USD","in_stock":true},{"title":"1\" Mass Flow Controller \/ 6061 T6 Aluminum","offer_id":46314358636713,"sku":null,"price":4095.0,"currency_code":"USD","in_stock":true},{"title":"1\" Mass Flow Controller \/ Nylon 6\/6","offer_id":46314358669481,"sku":null,"price":3995.0,"currency_code":"USD","in_stock":true},{"title":"2\" Mass Flow Meter \/ 316-Stainless Steel","offer_id":46154427498665,"sku":null,"price":3300.0,"currency_code":"USD","in_stock":true},{"title":"2\" Mass Flow Meter \/ 6061 T6 Aluminum","offer_id":46154427662505,"sku":null,"price":3000.0,"currency_code":"USD","in_stock":true},{"title":"2\" Mass Flow Meter \/ Nylon 6\/6","offer_id":46154427826345,"sku":null,"price":2900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/1_inch_Stainless_Mass_FLow_MeterWithDisplay.png?v=1571610970"},{"product_id":"2-inch-thermal-mass-flow-meter","title":"2\" Thermal Mass Flow Meter \u003cbr\u003efor Gas Flow","description":"\u003cp\u003eA thermal mass flow meter is a precision instrument that measures gas mass flow. The device is used in a wide range of applications in many industries.\u003c\/p\u003e\n\u003cp\u003eA thermal mass flow meter is a precision instrument that measures gas mass flow. The device is used in a wide range of applications in many industries.\u003c\/p\u003e\n\u003cp\u003eEASY to use Low Flow Mass Flow Meters. Check our stock \u0026amp; prices that beats our competition.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003cdiv class=\"cgt-desc\"\u003e\n\u003cul class=\"tabs clearfix\"\u003e\n\u003cli\u003e\u003ca class=\"active\" href=\"#tab-1\" data-mce-href=\"#tab-1\"\u003eDisplay\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab-2\" data-mce-href=\"#tab-2\"\u003eSpecifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab-3\" data-mce-href=\"#tab-3\"\u003eVideos\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab-4\" data-mce-href=\"#tab-4\"\u003eUser Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"cgt-content\" style=\"margin-top:0;\"\u003e\n\u003cdiv class=\"tab active\" id=\"tab-1\"\u003e\n\u003ch2\u003e2\" NPT 0-80 SCFM (136 SM3\/Hr) and Temperature\u003c\/h2\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"tab\" id=\"tab-2\"\u003e\n    \u003cul\u003e\n        \u003cli\u003eChoose Material 316 SS, 6061 T6 Aluminum or Nylon 6\/6\u003c\/li\u003e\n        \u003cli\u003eChoose Air Flow range to 0-40, 50, 60, 70, and 80 SCFM\u003c\/li\u003e\n        \u003cli\u003eAccuracy: +\/- 1% of reading plus +\/-0.5% of full scale\u003c\/li\u003e\n        \u003cli\u003eRepeatability of +\/- 0.2% of full scale\u003c\/li\u003e\n        \u003cli\u003e2” MNPT Pipe size\u003c\/li\u003e\n        \u003cli\u003eOLED Display\u003c\/li\u003e\n        \u003cli\u003eMeasures any inert gas and any non-condensing clean gas\u003c\/li\u003e\n        \u003cli\u003eFlammable gases: methane, propane, digester gas, natural gas\u003c\/li\u003e\n        \u003cli\u003e100:1 turndown\u003c\/li\u003e\n        \u003cli\u003eTemperature:\n   \u003cul\u003e\n        \u003cli\u003eGas: -40°F (-40°C) to 350°F (200°C)\u003c\/li\u003e\n        \u003cli\u003eAmbient: -40° F to 120° F (-40° C to 50° C)\u003c\/li\u003e\n   \u003c\/ul\u003e\n   \u003c\/li\u003e\n        \u003cli\u003eAdjustable Response time from .1 to 6 seconds to achieve 63% of final value\u003c\/li\u003e\n        \u003cli\u003ePower Requirement 18 to 30 VDC (regulated), 125 mA maximum;\u003c\/li\u003e\n        \u003cli\u003eWetted Materials: Nylon 6\/6, 6061T6 Aluminum, \u0026amp; 316 stainless-steel\u003c\/li\u003e\n        \u003cli\u003eOutput signals: Modbus RTU, USB-RS-232, 4–20 mA , 0–5 VDC, and Pulse User definable pulse or frequency for totalized or flow rate indication.\u003c\/li\u003e\n        \u003cli\u003eDigital communications solutions include: Modbus RTU, USB, Bluetooth\u003c\/li\u003e\n        \u003cli\u003eIP66 Enclosure\u003c\/li\u003e\n   \u003c\/ul\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"tab\" id=\"tab-3\"\u003e\n    \u003cp\u003eThe video below shows how the Tactical Flow Meter works and what advantages it has over conventional Thermal Mass Flow meters, such as the Sierra Instruments Model 840 or Sierra Instruments Model 830 series Thermal Mass Flow Meters.\u003c\/p\u003e\n    \u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/oyFpEr75fb4?rel=0\u0026amp;showinfo=0\" allowfullscreen=\"\" width=\"560\" height=\"315\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"tab\" id=\"tab-4\"\u003e\n\u003ch3 style=\"text-align: center;\"\u003eMass Flow Meters and Controllers Re-imagined\u003c\/h3\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003eCONGRATULATIONS!\u003c\/strong\u003e You just got your meter and you want to hook it up! We have installed TWO wires, a RED wire that hooks up to the + side of 24 VDC and the WHITE wire that hooks up to the GROUND side of your 24 VDC power supply with at least 200 mA capability.\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003ePlease connect it to your power supply and see how the meter works and download the \u003ca href=\"https:\/\/www.tacticalflowmeter.com\/products\/configuration-software\" target=\"_blank\" title=\"Configuration Software\" rel=\"noopener noreferrer\"\u003eConfiguration Software\u003c\/a\u003e and follow the instructions to connect to your meter with either the USB, BlueTooth, or ModBus RTU.\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003eWhen done remove those two short wires and keep handy for other quick tests.\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003eMost folks want to get moving quickly so they opt to use the BlueTooth because no wiring is required. Remember, as shown below, that you FIRST tell your PC that you have a BlueTooth located nearby and PAIR it with the Pairing Code of 1234. Windows may enumerate TWO COM ports, it is normally the FIRST one it chooses.\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cstrong\u003eGet your two page Wiring Diagram below, download\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Wiring Diagrams\" target=\"_blank\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TacticalFlowConnectionDiagramR1.pdf?3437022259034187517\" rel=\"noopener noreferrer\"\u003ehere\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003eThe links and videos below are available from the user program and they automatically serve the content that is related to the function that is being used on the screen the user is using. There is no need to review these videos unless you have a desire to see how the meter works without actually having to use one. Consider these videos as a video guided tour of the Thermal Mass Flow Meter. These videos are fully responsive so you may view them on a Smart Phone.\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003cbr\u003e\u003cstrong\u003eMain User Program Index\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp\u003eClick \u003ca href=\"#Main_User_Instructions\"\u003ehere\u003c\/a\u003e to view the Complete User Instructions. \u003cbr\u003eClick \u003ca href=\"#Bluetooth\"\u003ehere\u003c\/a\u003e to view how to connect to Bluetooth.\u003cbr\u003eClick \u003ca href=\"#Bluetooth2\"\u003ehere\u003c\/a\u003e to view for MORE Bluetooth tips.\u003cbr\u003eClick \u003ca href=\"#Flowmeter_Validation\"\u003ehere\u003c\/a\u003e to view how to Validate Your Flow Meter. \u003cbr\u003eClick \u003ca href=\"#Datalog\"\u003ehere\u003c\/a\u003e to view how to use the Datalog. \u003cbr\u003eClick \u003ca href=\"#OLED_Screens\"\u003ehere\u003c\/a\u003e to learn how to read the OLED Local Display.\u003cbr\u003eClick \u003ca href=\"#QR\"\u003ehere\u003c\/a\u003e to show QR Code so you can view this site on your SmartPhone. \u003cbr\u003eClick \u003ca href=\"#Outputs\"\u003ehere\u003c\/a\u003e to view How to use the 0-5VDC and 4-20mA Outputs, basic overview.\u003cbr\u003eClick \u003ca href=\"#Outputs2\"\u003ehere\u003c\/a\u003e to view Details on adjusting 0-5VDC and 4-20mA Outputs. \u003cbr\u003e\u003cstrong\u003eFor Wiring Diagrams and connections Click \u003ca title=\"Mass Flow Meter Wiring diagrams\" target=\"_blank\" href=\"https:\/\/www.tacticalflowmeter.com\/pages\/wiring-and-connection-instructions\" rel=\"noopener noreferrer\"\u003ehere\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003eClick \u003ca href=\"#Terminal\"\u003ehere\u003c\/a\u003e to use the Terminal and ModBus and RealTime graph.\u003cbr\u003eClick \u003ca href=\"https:\/\/www.tacticalflowmeter.com\/pages\/modbus-and-usb-serial-terminal-instructions\" target=\"_blank\" title=\"How to use ModBus for Tactical Flow Meter thermal mass flow meters\" rel=\"noopener noreferrer\"\u003ehere\u003c\/a\u003e for detailed ModBus instructions\u003cbr\u003eClick \u003ca href=\"#Total\"\u003ehere\u003c\/a\u003e to work with the Totalizer and Pulse Counter, basic overview.\u003cbr\u003eClick \u003ca href=\"#Total2\"\u003ehere\u003c\/a\u003e to Set Up your Totalizer and Pulse Counter with some examples.\u003cbr\u003eClick \u003ca href=\"#Setup\"\u003ehere\u003c\/a\u003e to view how to use Setup tab for enabling writing. \u003cbr\u003eClick \u003ca href=\"#Config\"\u003ehere\u003c\/a\u003e to use the Configuration tab to view the meter variables.\u003cbr\u003eClick \u003ca href=\"#Total\"\u003ehere\u003c\/a\u003e to work with the Totalizer and configure the pulse counter.\u003cbr\u003eClick \u003ca href=\"#Calibration\"\u003ehere\u003c\/a\u003e to work with the Calibration Screen for editing the calibration variables.\u003c\/p\u003e\n\u003cp\u003eThe table below shows the Register addresses that are in place to support the use the same register scheme used in any Sage Metering ModBus equipped Thermal Mass Flow Meter. The Sage Metering product indicates the raw flow reading in mW, typically in the range of 40 mW to 900 mW. As such, we scale the output of the Tactical Flow meter's 0-32767 Raw Ticks output to the range of 40 to 900 mW when using the ModBus command 582. This provides for easy comparison of the raw values.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/SageMeteringEmulationMode_a412bfe7-a1df-4e63-821f-dd2a2f190744_large.png?v=1497052585\" alt=\"Sage Metering ModBus Emulation Registers\"\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"OLED_Screens\"\u003e\u003c\/a\u003e \u003cstrong\u003eOLED Screen Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003eRefer to the screen samples below to understand what each of the screens means and indicates to the user.\u003c\/strong\u003e\u003c\/div\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/ScreenDescrip-TOP_large.jpg?v=1488862612\" alt=\"\" height=\"685\" width=\"577\"\u003e\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/BottomScreens_large.jpg?v=1488862403\" alt=\"\" height=\"566\" width=\"582\"\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"QR\"\u003e\u003c\/a\u003e \u003cstrong\u003eQR Code for this page:\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003cstrong\u003eThe QR Code is VERY HANDY to read with your Smart Phone so you can have these instructions on your portable device when you go to the flow meter in the field. These videos render very fast on all Smart Phones.\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/QR-Code-MANUAL-Orange_medium.png?v=1484805405\" alt=\"Manual\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Main_User_Instructions\"\u003e\u003c\/a\u003e \u003cstrong\u003eMain User Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Pv02YwLerwY?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the operation of the User Program with a Windows Machine to allow you to understand the basic principles of the mass flow meter\/controller. We demonstrate the operation of the User Program with a Windows Machine to allow you to understand the basic principles of the mass flow meter\/controller. This video show all aspects of the program and is available in each category from the index values shown above.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Bluetooth\"\u003e\u003c\/a\u003e \u003cstrong\u003eBluetooth Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/sqY-vxhAj_o?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003eWe demonstrate the method of setting up the mass flow meter\/controller with a Windows Machine with Bluetooth using the User Program. \u003cbr\u003eThe Pairing Code is 1234 on all the flow meters.\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Bluetooth2\"\u003e\u003c\/a\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cstrong\u003eMORE Bluetooth Instructions\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/hZumIbnAZBk?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate more methods for using the PC and Bluetooth and how to discover which Bluetooth device is connected to your Flow Meter.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Flowmeter_Validation\"\u003e\u003c\/a\u003e \u003cstrong\u003eFlowmeter Validation Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/HGUdNmQXuJw?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of validating the calibration of the mass flow meter\/controller with a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Datalog\"\u003e\u003c\/a\u003e \u003cstrong\u003eDatalog Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/RBUQnlQZ7UQ?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of downloading\/viewing and plotting the datalog data from the mass flow meter\/controller with a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Outputs\"\u003e\u003c\/a\u003e \u003cstrong\u003eVoltage Output Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/Pv02YwLerwY?\u0026amp;rel=0\u0026amp;start=181\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThis video shows how the 4-20 and 0-5 VDC Outputs can be validated manually.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Outputs2\"\u003e\u003c\/a\u003e \u003cstrong\u003eExamples of adjusting the 0-5 and 4-20 outputs\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/fEEOVydd-ac?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThis video shows examples of adjusting the 4-20 and 0-5 VDC outputs to correlate with the attached data acquisition system.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Bluetooth\"\u003e\u003c\/a\u003e \u003cstrong\u003eBluetooth Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/sqY-vxhAj_o?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of setting up the mass flow meter\/controller with a Windows Machine with Bluetooth using the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Flowmeter_Validation\"\u003e\u003c\/a\u003e \u003cstrong\u003eFlowmeter Validation Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/HGUdNmQXuJw?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of validating the calibration of the mass flow meter\/controller on a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Datalog\"\u003e\u003c\/a\u003e \u003cstrong\u003eDatalog Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/ANSySVSRbZk?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of downloading\/viewing and plotting the datalog data from the mass flow meter\/controller with a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Outputs\"\u003e\u003c\/a\u003e \u003cstrong\u003eVoltage and Current Output Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/Pv02YwLerwY?\u0026amp;rel=0\u0026amp;start=181\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of validating the calibration of the mass flow meter\/controller with a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Terminal\"\u003e\u003c\/a\u003e \u003cstrong\u003eTerminal and ModBus Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/Pv02YwLerwY?\u0026amp;rel=0\u0026amp;start=311\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of using the Terminal and the ModBus functions for the mass flow meter\/controller with a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Total\"\u003e\u003c\/a\u003e \u003cstrong\u003eTotalizer and Pulse Counter Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/Pv02YwLerwY?\u0026amp;rel=0\u0026amp;start=472\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of accessing the totalizer and pulse output of the mass flow meter\/controller for a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Total2\"\u003e\u003c\/a\u003e \u003cstrong\u003eTotalizer and Pulse Counter Configuration Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/eURtDG28X_U?\u0026amp;rel=0\u0026amp;start=472\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of setting up your Pulse Counter to count at the rate that is supported by your connected pulse counter. We show the part that accomplishes the pulse counting as well as the specification sheet for an Omron H7EC as an example.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cstrong\u003eSetup Instructions\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/Pv02YwLerwY?\u0026amp;rel=0\u0026amp;start=847\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the setup screen of the mass flow meter\/controller for a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Config\"\u003e\u003c\/a\u003e \u003cstrong\u003eConfiguration Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/Pv02YwLerwY?\u0026amp;rel=0\u0026amp;start=656\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of accessing the configuration of the mass flow meter\/controller for a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Calibration\"\u003e\u003c\/a\u003e \u003cstrong\u003eCalibration Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Pv02YwLerwY?\u0026amp;rel=0\u0026amp;start=0\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of accessing the calibration features of the mass flow meter\/controller for a Windows Machine with the User Program.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Tactical Flow Meter","offers":[{"title":"316-Stainless Steel \/ 40 SCFM","offer_id":36355455753,"sku":"TFM2-SS-40","price":3300.0,"currency_code":"USD","in_stock":true},{"title":"316-Stainless Steel \/ 50 SCFM","offer_id":36355785737,"sku":"TFM2-SS-50","price":3300.0,"currency_code":"USD","in_stock":true},{"title":"316-Stainless Steel \/ 60 SCFM","offer_id":36355785801,"sku":"TFM2-SS-60","price":3300.0,"currency_code":"USD","in_stock":true},{"title":"316-Stainless Steel \/ 70 SCFM","offer_id":36355785865,"sku":"TFM2-SS-70","price":3300.0,"currency_code":"USD","in_stock":true},{"title":"316-Stainless Steel \/ 80 SCFM","offer_id":36355785929,"sku":"TFM2-SS-80","price":3300.0,"currency_code":"USD","in_stock":true},{"title":"6061 T6 Aluminum \/ 40 SCFM","offer_id":36355785993,"sku":"TFM2-AL-40","price":3000.0,"currency_code":"USD","in_stock":true},{"title":"6061 T6 Aluminum \/ 50 SCFM","offer_id":36355786057,"sku":"TFM2-AL-50","price":3000.0,"currency_code":"USD","in_stock":true},{"title":"6061 T6 Aluminum \/ 60 SCFM","offer_id":36355786121,"sku":"TFM2-AL-60","price":3000.0,"currency_code":"USD","in_stock":true},{"title":"6061 T6 Aluminum \/ 70 SCFM","offer_id":36355786185,"sku":"TFM2-AL-70","price":3000.0,"currency_code":"USD","in_stock":true},{"title":"6061 T6 Aluminum \/ 80 SCFM","offer_id":36355786249,"sku":"TFM2-AL-80","price":3000.0,"currency_code":"USD","in_stock":true},{"title":"Nylon 6\/6 \/ 40 SCFM","offer_id":36355786313,"sku":"TFM2-NY-40","price":2900.0,"currency_code":"USD","in_stock":true},{"title":"Nylon 6\/6 \/ 50 SCFM","offer_id":36355786377,"sku":"TFM2-NY-50","price":2900.0,"currency_code":"USD","in_stock":true},{"title":"Nylon 6\/6 \/ 60 SCFM","offer_id":36355786441,"sku":"TFM2-NY-60","price":2900.0,"currency_code":"USD","in_stock":true},{"title":"Nylon 6\/6 \/ 70 SCFM","offer_id":36355786505,"sku":"TFM2-NY-70","price":2900.0,"currency_code":"USD","in_stock":true},{"title":"Nylon 6\/6 \/ 80 SCFM","offer_id":36355786569,"sku":"TFM2-NY-80","price":2900.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/2_inch_Stainless_Mass_FLow_MeterWithDisplay.png?v=1571610970"},{"product_id":"1-tactical-flow-controller","title":"1\" Thermal Mass Flow Controller \u003cbr\u003efor Gas Flow","description":"\u003cp\u003eOur thermal Mass Flow Meter or Controller is capable of providing\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edirect measurement of mass flow\u003c\/strong\u003e, as opposed to most other methods that measure volumetric flow \u0026amp; require separate measurements for temperature \u0026amp; pressure in order to calculate density \u0026amp;, ultimately, the mass flow.\u003c\/p\u003e\n\u003cp\u003eWe also sell gas Mass flow Controllers built to measure air \u0026amp; gas. These flow meters shipping from stock (usually within 48hrs) \u0026amp; are configured for you.\u003c\/p\u003e\n\u003cp\u003eOur EASY to use gas Mass Flow Controllers are in stock at prices that beat our competition.\u003c\/p\u003e\n\u003c!-- split --\u003e\n\u003cdiv class=\"cgt-desc\"\u003e\n\u003cul class=\"tabs clearfix\"\u003e\n\u003cli\u003e\u003ca class=\"active\" href=\"#tab-1\" data-mce-href=\"#tab-1\"\u003eDisplay\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab-2\" data-mce-href=\"#tab-2\"\u003eSpecifications\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab-3\" data-mce-href=\"#tab-3\"\u003eVideos\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"#tab-4\" data-mce-href=\"#tab-4\"\u003eUser Manual\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv class=\"cgt-content\" style=\"margin-top: 0;\"\u003e\n\u003cdiv class=\"tab active\" id=\"tab-1\"\u003e\n\u003ch2\u003e1\" NPT 0-20 SCFM AND TEMPERATURE\u003c\/h2\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab\" id=\"tab-2\"\u003e\n\u003cul\u003e\n\u003cli\u003eAccuracy: +\/- 1% of reading plus +\/-0.5% of full scale\u003c\/li\u003e\n\u003cli\u003eFlow Control adjustable via digital communications, on board encoder, or SmartPhone.\u003c\/li\u003e\n\u003cli\u003eRepeatability of +\/- 0.2% of full scale\u003c\/li\u003e\n\u003cli\u003e1” MNPT Pipe size Inlet\/ 1\" FNPT pipe size outlet\u003c\/li\u003e\n\u003cli\u003eFlow control range to 0-20 SCFM\u003c\/li\u003e\n\u003cli\u003eOLED Display\u003c\/li\u003e\n\u003cli\u003eMeasures any inert gas and any non-condensing clean gas\u003c\/li\u003e\n\u003cli\u003eFlammable gases: methane, propane, digester gas, natural gas\u003c\/li\u003e\n\u003cli\u003e100:1 turndown\u003c\/li\u003e\n\u003cli\u003eTemperature:\n\u003cul\u003e\n\u003cli\u003eGas: -40°F (-40°C) to 350°F (200°C)\u003c\/li\u003e\n\u003cli\u003eAmbient: -40° F to 120° F (-40° C to 50° C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePressure, 25 PSIG Max\u003c\/li\u003e\n\u003cli\u003eAdjustable Response time from .1 to 6 seconds to achieve 63% of final value\u003c\/li\u003e\n\u003cli\u003ePower Requirement 18 to 30 VDC (regulated), 125 mA maximum;\u003c\/li\u003e\n\u003cli\u003eNylon 6\/6, 6061T6 Aluminum or 316 stainless-steel construction\u003c\/li\u003e\n\u003cli\u003eOutput signals: Modbus RTU, USB-RS-232, 4–20 mA , 0–5 VDC, and Pulse User definable pulse or frequency for totalized or flow rate indication\u003c\/li\u003e\n\u003cli\u003eDigital communications solutions include: Modbus RTU, USB, Bluetooth\u003c\/li\u003e\n\u003cli\u003eIP66 Enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"tab\" id=\"tab-3\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"video-wrapper\"\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/gS5nwwXxCwc\" height=\"298\" width=\"1136\" allowfullscreen=\"\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture\" frameborder=\"0\"\u003e\u003c\/iframe\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\n\u003cdiv class=\"tab\" id=\"tab-4\"\u003e\n\u003ch3 style=\"text-align: center;\"\u003eMass Flow Meters and Controllers Re-imagined\u003c\/h3\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cstrong\u003eCONGRATULATIONS!\u003c\/strong\u003e You just got your meter and you want to hook it up! We have installed TWO wires, a RED wire that hooks up to the + side of 24 VDC and the WHITE wire that hooks up to the GROUND side of your 24 VDC power supply with at least 200 mA capability.\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003ePlease connect it to your power supply and see how the meter works and download the \u003ca href=\"https:\/\/www.tacticalflowmeter.com\/products\/configuration-software\" target=\"_blank\" title=\"Configuration Software\" rel=\"noopener noreferrer\"\u003eConfiguration Software\u003c\/a\u003e and follow the instructions to connect to your meter with either the USB, BlueTooth, or ModBus RTU.\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003eWhen done remove those two short wires and keep handy for other quick tests.\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003eMost folks want to get moving quickly so they opt to use the BlueTooth because no wiring is required. Remember, as shown below, that you FIRST tell your PC that you have a BlueTooth located nearby and PAIR it with the Pairing Code of 1234. Windows may enumerate TWO COM ports, it is normally the FIRST one it chooses.\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cstrong\u003eGet your two page Wiring Diagram below, download\u003cspan\u003e \u003c\/span\u003e\u003ca title=\"Wiring Diagrams\" target=\"_blank\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TacticalFlowConnectionDiagramR1.pdf?3437022259034187517\" rel=\"noopener noreferrer\"\u003ehere\u003c\/a\u003e\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: left;\"\u003eThe links and videos below are available from the user program and they automatically serve the content that is related to the function that is being used on the screen the user is using. There is no need to review these videos unless you have a desire to see how the meter works without actually having to use one. Consider these videos as a video guided tour of the Thermal Mass Flow Meter. These videos are fully responsive so you may view them on a Smart Phone.\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003cbr\u003e\u003cstrong\u003eMain User Program Index\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp\u003eClick \u003ca href=\"#Main_User_Instructions\"\u003ehere\u003c\/a\u003e to view the Complete User Instructions. \u003cbr\u003eClick \u003ca href=\"#Bluetooth\"\u003ehere\u003c\/a\u003e to view how to connect to Bluetooth.\u003cbr\u003eClick \u003ca href=\"#Bluetooth2\"\u003ehere\u003c\/a\u003e to view for MORE Bluetooth tips.\u003cbr\u003eClick \u003ca href=\"#Flowmeter_Validation\"\u003ehere\u003c\/a\u003e to view how to Validate Your Flow Meter. \u003cbr\u003eClick \u003ca href=\"#Datalog\"\u003ehere\u003c\/a\u003e to view how to use the Datalog. \u003cbr\u003eClick \u003ca href=\"#OLED_Screens\"\u003ehere\u003c\/a\u003e to learn how to read the OLED Local Display.\u003cbr\u003eClick \u003ca href=\"#QR\"\u003ehere\u003c\/a\u003e to show QR Code so you can view this site on your SmartPhone. \u003cbr\u003eClick \u003ca href=\"#Outputs\"\u003ehere\u003c\/a\u003e to view How to use the 0-5VDC and 4-20mA Outputs, basic overview.\u003cbr\u003eClick \u003ca href=\"#Outputs2\"\u003ehere\u003c\/a\u003e to view Details on adjusting 0-5VDC and 4-20mA Outputs. \u003cbr\u003e\u003cstrong\u003eFor Wiring Diagrams and connections Click \u003ca title=\"Mass Flow Meter Wiring diagrams\" target=\"_blank\" href=\"https:\/\/www.tacticalflowmeter.com\/pages\/wiring-and-connection-instructions\" rel=\"noopener noreferrer\"\u003ehere\u003c\/a\u003e\u003c\/strong\u003e\u003cbr\u003eClick \u003ca href=\"#Terminal\"\u003ehere\u003c\/a\u003e to use the Terminal and ModBus and RealTime graph.\u003cbr\u003eClick \u003ca href=\"https:\/\/www.tacticalflowmeter.com\/pages\/modbus-and-usb-serial-terminal-instructions\" target=\"_blank\" title=\"How to use ModBus for Tactical Flow Meter thermal mass flow meters\" rel=\"noopener noreferrer\"\u003ehere\u003c\/a\u003e for detailed ModBus instructions\u003cbr\u003eClick \u003ca href=\"#Total\"\u003ehere\u003c\/a\u003e to work with the Totalizer and Pulse Counter, basic overview.\u003cbr\u003eClick \u003ca href=\"#Total2\"\u003ehere\u003c\/a\u003e to Set Up your Totalizer and Pulse Counter with some examples.\u003cbr\u003eClick \u003ca href=\"#Setup\"\u003ehere\u003c\/a\u003e to view how to use Setup tab for enabling writing. \u003cbr\u003eClick \u003ca href=\"#Config\"\u003ehere\u003c\/a\u003e to use the Configuration tab to view the meter variables.\u003cbr\u003eClick \u003ca href=\"#Total\"\u003ehere\u003c\/a\u003e to work with the Totalizer and configure the pulse counter.\u003cbr\u003eClick \u003ca href=\"#Calibration\"\u003ehere\u003c\/a\u003e to work with the Calibration Screen for editing the calibration variables.\u003c\/p\u003e\n\u003cp\u003eThe table below shows the Register addresses that are in place to support the use the same register scheme used in any Sage Metering ModBus equipped Thermal Mass Flow Meter. The Sage Metering product indicates the raw flow reading in mW, typically in the range of 40 mW to 900 mW. As such, we scale the output of the Tactical Flow meter's 0-32767 Raw Ticks output to the range of 40 to 900 mW when using the ModBus command 582. This provides for easy comparison of the raw values.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg src=\"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/SageMeteringEmulationMode_a412bfe7-a1df-4e63-821f-dd2a2f190744_large.png?v=1497052585\" alt=\"Sage Metering ModBus Emulation Registers\"\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"OLED_Screens\"\u003e\u003c\/a\u003e \u003cstrong\u003eOLED Screen Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003eRefer to the screen samples below to understand what each of the screens means and indicates to the user.\u003c\/strong\u003e\u003c\/div\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/ScreenDescrip-TOP_large.jpg?v=1488862612\" alt=\"\" height=\"685\" width=\"577\"\u003e\u003c\/h3\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/BottomScreens_large.jpg?v=1488862403\" alt=\"\" height=\"566\" width=\"582\"\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"QR\"\u003e\u003c\/a\u003e \u003cstrong\u003eQR Code for this page:\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003e\u003cstrong\u003eThe QR Code is VERY HANDY to read with your Smart Phone so you can have these instructions on your portable device when you go to the flow meter in the field. These videos render very fast on all Smart Phones.\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/QR-Code-MANUAL-Orange_medium.png?v=1484805405\" alt=\"Manual\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Main_User_Instructions\"\u003e\u003c\/a\u003e \u003cstrong\u003eMain User Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Pv02YwLerwY?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the operation of the User Program with a Windows Machine to allow you to understand the basic principles of the mass flow meter\/controller. We demonstrate the operation of the User Program with a Windows Machine to allow you to understand the basic principles of the mass flow meter\/controller. This video show all aspects of the program and is available in each category from the index values shown above.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Bluetooth\"\u003e\u003c\/a\u003e \u003cstrong\u003eBluetooth Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/sqY-vxhAj_o?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003ch3 style=\"text-align: center;\"\u003eWe demonstrate the method of setting up the mass flow meter\/controller with a Windows Machine with Bluetooth using the User Program. \u003cbr\u003eThe Pairing Code is 1234 on all the flow meters.\u003c\/h3\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Bluetooth2\"\u003e\u003c\/a\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cstrong\u003eMORE Bluetooth Instructions\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/hZumIbnAZBk?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate more methods for using the PC and Bluetooth and how to discover which Bluetooth device is connected to your Flow Meter.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Flowmeter_Validation\"\u003e\u003c\/a\u003e \u003cstrong\u003eFlowmeter Validation Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/HGUdNmQXuJw?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of validating the calibration of the mass flow meter\/controller with a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Datalog\"\u003e\u003c\/a\u003e \u003cstrong\u003eDatalog Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/RBUQnlQZ7UQ?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of downloading\/viewing and plotting the datalog data from the mass flow meter\/controller with a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Outputs\"\u003e\u003c\/a\u003e \u003cstrong\u003eVoltage Output Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/Pv02YwLerwY?\u0026amp;rel=0\u0026amp;start=181\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThis video shows how the 4-20 and 0-5 VDC Outputs can be validated manually.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Outputs2\"\u003e\u003c\/a\u003e \u003cstrong\u003eExamples of adjusting the 0-5 and 4-20 outputs\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/fEEOVydd-ac?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eThis video shows examples of adjusting the 4-20 and 0-5 VDC outputs to correlate with the attached data acquisition system.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Bluetooth\"\u003e\u003c\/a\u003e \u003cstrong\u003eBluetooth Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/sqY-vxhAj_o?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of setting up the mass flow meter\/controller with a Windows Machine with Bluetooth using the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Flowmeter_Validation\"\u003e\u003c\/a\u003e \u003cstrong\u003eFlowmeter Validation Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/HGUdNmQXuJw?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of validating the calibration of the mass flow meter\/controller on a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Datalog\"\u003e\u003c\/a\u003e \u003cstrong\u003eDatalog Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/ANSySVSRbZk?rel=0\u0026amp;controls=1\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of downloading\/viewing and plotting the datalog data from the mass flow meter\/controller with a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Outputs\"\u003e\u003c\/a\u003e \u003cstrong\u003eVoltage and Current Output Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/Pv02YwLerwY?\u0026amp;rel=0\u0026amp;start=181\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of validating the calibration of the mass flow meter\/controller with a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Terminal\"\u003e\u003c\/a\u003e \u003cstrong\u003eTerminal and ModBus Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/Pv02YwLerwY?\u0026amp;rel=0\u0026amp;start=311\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of using the Terminal and the ModBus functions for the mass flow meter\/controller with a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Total\"\u003e\u003c\/a\u003e \u003cstrong\u003eTotalizer and Pulse Counter Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/Pv02YwLerwY?\u0026amp;rel=0\u0026amp;start=472\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of accessing the totalizer and pulse output of the mass flow meter\/controller for a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Total2\"\u003e\u003c\/a\u003e \u003cstrong\u003eTotalizer and Pulse Counter Configuration Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/eURtDG28X_U?\u0026amp;rel=0\u0026amp;start=472\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of setting up your Pulse Counter to count at the rate that is supported by your connected pulse counter. We show the part that accomplishes the pulse counting as well as the specification sheet for an Omron H7EC as an example.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003cstrong\u003eSetup Instructions\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/Pv02YwLerwY?\u0026amp;rel=0\u0026amp;start=847\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the setup screen of the mass flow meter\/controller for a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Config\"\u003e\u003c\/a\u003e \u003cstrong\u003eConfiguration Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"\/\/www.youtube.com\/embed\/Pv02YwLerwY?\u0026amp;rel=0\u0026amp;start=656\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of accessing the configuration of the mass flow meter\/controller for a Windows Machine with the User Program.\u003c\/p\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\n\u003ca id=\"Calibration\"\u003e\u003c\/a\u003e \u003cstrong\u003eCalibration Instructions\u003c\/strong\u003e\n\u003c\/div\u003e\n\u003cp style=\"text-align: center;\"\u003eClick \u003ca href=\"#TOP\"\u003ehere\u003c\/a\u003e to go back to the Index.\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ciframe src=\"https:\/\/www.youtube.com\/embed\/Pv02YwLerwY?\u0026amp;rel=0\u0026amp;start=0\u0026amp;showinfo=0\" allowfullscreen=\"\" frameborder=\"0\" height=\"315\" width=\"560\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: center;\"\u003eWe demonstrate the method of accessing the calibration features of the mass flow meter\/controller for a Windows Machine with the User Program.\u003c\/p\u003e\n\u003c\/div\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Tactical Flow Meter","offers":[{"title":"316 Stainless Steel","offer_id":29363635657,"sku":"TFC2-SS","price":4195.0,"currency_code":"USD","in_stock":true},{"title":"Anodized Aluminum","offer_id":29363635721,"sku":"TFC2-AL","price":4095.0,"currency_code":"USD","in_stock":true},{"title":"Nylon 6\/6","offer_id":29363635785,"sku":"TFC2-NY","price":3995.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/1_inch_Stainless_Steel_Mass_FLow_ControllerWithDisplay.png?v=1654757242"},{"product_id":"low-flow-tactical-flow-meter-battery-powered-for-2-years","title":"15 SLPM to 100 SLPM Low Flow Tactical Flow Meter, Battery Powered for 2 years","description":"\u003ch2\u003e\u003cstrong\u003eMASS FLOW METER 0-15 and 100 SLPM SIZE RANGES\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003ch3 style=\"float: left;\"\u003e\u003cb\u003e\u003cimg style=\"float: left;\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/LCD_MassFlowMeter_compact.png?v=1527362451\" alt=\"\"\u003eFeatures LARGE LCD display, shows the Flow Rate, Total Flow, Temperature, Flow Units, Total Units, Temperature Units, and the gas number is shown along with battery charge indicator.\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eThe battery will typically last more than 2 years under normal use (Not included with meter). If the user needs an analog output or ModBus RTU then a power supply of 12-24 VDC with a capability of 50 mA must be used to power the loops. Battery power switch on top of unit.\u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eFlow Body Material 316 SS\u003c\/li\u003e\n\u003cli\u003eSelect 15 SLPM or 100 SLPM relative to Nitrogen Other ranges available.\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/- 1.5% of reading + 0.5% FS\u003c\/li\u003e\n\u003cli\u003eRepeatability of +\/- 0.5% of reading\u003c\/li\u003e\n\u003cli\u003e1\/4\", 3\/8\"  and 1\/2\" Male NPT\u003c\/li\u003e\n\u003cli\u003eLCD Display\u003c\/li\u003e\n\u003cli\u003eMeasures any inert gas and any non-condensing clean gas.\u003c\/li\u003e\n\u003cli\u003eFlammable gases: methane, propane, digester gas, natural gas\u003c\/li\u003e\n\u003cli\u003e100:1 turndown\u003c\/li\u003e\n\u003cli\u003eTemperature:                \u003c\/li\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eGas: 14°F (-10°C) to 131°F (55°C)\u003c\/li\u003e\n\u003cli\u003eAmbient: 14°F (-10°C) to 149°F (65°C)              \u003c\/li\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cli\u003eBattery Life is Typically 2 years with D Cell 3.6 V 1900 mAh Lithium Ion Battery Also runs on 12-24 VDC WITHOUT the need for a battery. Battery not included because of shipping restrictions.\u003c\/li\u003e\n\u003cli\u003eSUPER FAST Response time 250 milliseconds.\u003c\/li\u003e\n\u003cli\u003ePower Requirement: 12 to 24 VDC (regulated), 50 mA maximum;   \u003c\/li\u003e\n\u003cli\u003eWetted Materials may include: 316 stainless-steel, Silicon Nitride, Pyrex Glass, Alumina ceramics, gold, aluminum, nickel, FR-4 and Pb-free solder may come in contact with gas.\u003c\/li\u003e\n\u003cli\u003eOutput signals: Modbus RTU, 4–20 mA , 0–5 VDC, and User definable pulse  output (3VDC) for flow rate indication. Totalizer is non-resettable suitable for billing applications. \u003c\/li\u003e\n\u003cli\u003eDigital communications: Modbus RTU \u003c\/li\u003e\n\u003cli\u003eProof Pressure 1.2 MPa, 175 PSIG.\u003c\/li\u003e\n\u003cli\u003eNEMA 1 Enclosure for Lab and indoor use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca title='1\"Tactical Flow Meter Brochure' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/1-InchMFMR829g.pdf?4914467433057142029\" target=\"_blank\"\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/Dimensions_grande.png?v=1527359353\"\u003e\u003c\/a\u003eBattery not included, We are not authorized to ship Lithium Batteries for safety reasons, Order battery with these specs. EEMB 3.6 V D Size Lithium Battery ER34615 19000 mAh Li SOCL2 UL Certified Non Rechargeable 3.6 Volt Lithium Thionyl Chloride Battery. Easy to get from Amazon\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Model 5100 Mass Flow Meter Quick Manual Rev 9\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MF5100_QuickManual_R9.pdf?v=1601331754\" target=\"_blank\"\u003eBrochure and Quick Manual \u003c\/a\u003e(QR Code for Smart Phone Uaers)\u003c\/p\u003e\n\u003cp\u003e\u003cimg data-mce-fragment=\"1\" height=\"296\" width=\"296\" alt=\"QR Code 5100 Series Mass Flow Meter Manual Rev 9\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/qr-codeManualR-9_f413cf04-e70d-41bf-9f60-b100a48e1f2b_480x480.png?v=1601331963\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/qr-codeManualR-9_f413cf04-e70d-41bf-9f60-b100a48e1f2b_480x480.png?v=1601331963\"\u003e  \u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg style=\"float: none;\" alt=\"Low FLow Meter ModBusPoll Infographic\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Low-Flow-Meter-ModBus-Poll-Infographicpng_2048x2048.png?v=1622662289\"\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eGas K-Factors for GCF Term:\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAir (calibrated gas, GCF = 1000), N2 (no change, GCF = 1000), O2 (no change, GCF = 1000); Argon (GCF=1150); and CO2 (GCF=740). \u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Tactical Flow Meter","offers":[{"title":"0-15 SLPM \/ I have my own","offer_id":42082355085481,"sku":"LMFM51-2 15 lpm no conn","price":2215.0,"currency_code":"USD","in_stock":true},{"title":"0-15 SLPM \/ DB-15 with 8' Cable","offer_id":42082355118249,"sku":"LMFM51-3 15 lpm 8 ft cable","price":2235.0,"currency_code":"USD","in_stock":true},{"title":"0-15 SLPM \/ DB-15 with 10' Cable","offer_id":42082355151017,"sku":"LMFM51-4 15 lpm 10 ft cable","price":2255.0,"currency_code":"USD","in_stock":true},{"title":"0-100 SLPM \/ I have my own","offer_id":42082355216553,"sku":"LMFM51-6 100 lpm no conn","price":2215.0,"currency_code":"USD","in_stock":true},{"title":"0-100 SLPM \/ DB-15 with 8' Cable","offer_id":42082355249321,"sku":"LMFM51-7 100 lpm 8 ft cable","price":2235.0,"currency_code":"USD","in_stock":true},{"title":"0-100 SLPM \/ DB-15 with 10' Cable","offer_id":42082355282089,"sku":"LMFM51-8 100 lpm 10 ft cable","price":2255.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/MF-5000-MassFlowMeter.png?v=1629500859"},{"product_id":"magnetic-flow-meter","title":"Magnetic Flow Meter \u003cbr\u003efor Liquid Flow \u003cbr\u003e1\/2\" to 96\"","description":"\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMagnetic flow meters (MAG flow meters) are volumetric flow meters for measuring CONDUCTIVE LIQUIDS [Not Gases] that operate without any moving parts and are ideal for potable water and wastewater applications as well as ideal for any conductive or water based clean or dirty fluid. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMagnetic flow meters work exceptionally well for slurry and cement applications because they offer obstruction-free flow paths and accurately measure conductive fluids even in the presence of high solids content and abrasive materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eMagnetic flow meters will generally not work with hydrocarbons, distilled water, and many non-aqueous solutions as they require a conductive fluid of 5 microSiemens\/cm minimum.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOutstanding 0.5% Accuracy and 40:1 Turndown, in 1\/2\" to 96\" pipes, with the following liquids:  \u003c\/span\u003e\u003cstrong\u003ePotable Water, Well Water, Waste Water, Effluent, Sewage, Sludge, Cement, Oil Well Injection Water, Beer, Wine, Liquor, Fruit Juice, Dairy,  Irrigation MAG Meters, Chemical Reagent, or any electrically conductive liquid. \u003c\/strong\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c!--split--\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003eMagnetic Flow Meter Specifications\u003c\/h3\u003e\n\u003cdiv class=\"product-bullet-list\"\u003e\n\u003cul\u003e\n\u003cli\u003eElectrode Material: 316L SS\u003c\/li\u003e\n\u003cli\u003eWetted Materials: Teflon, 304 SS, \u0026amp; 316 SS\u003c\/li\u003e\n\u003cli\u003eFlow Body Material: 304 SS\u003c\/li\u003e\n\u003cli\u003eFlow Range: 0.3 - 12 m\/s\n\u003cul\u003e\n\u003cli\u003eNominal 0.3 - 10 m\/s for 0.5% Accuracy\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/- 0.5% of reading in water (From 0.3 m\/s to 10 m\/s)\u003c\/li\u003e\n\u003cli\u003eRepeatability: +\/- 0.15% of reading\u003c\/li\u003e\n\u003cli\u003ePipe Size: \n\u003cul\u003e\n\u003cli\u003eInline: 1\/2\" to 80\" 150# ANSI flange connections, Up to \u003cspan\u003e2500# available\u003c\/span\u003e custom\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eInsertion: 6\" to 96\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTemperature:\n\u003cul\u003e\n\u003cli\u003e  Liquid: 14°F (-10°C) to 350°F (180°C)\u003c\/li\u003e\n\u003cli\u003eAmbient: 14°F (-10°C) to 140°F (60°C\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Requirement: 24 VDC 20 Watts maximum;\u003c\/li\u003e\n\u003cli\u003eOutput signals: Modbus RTU, 4–20 mA, and 0-10 KHz for flow rate indication\u003c\/li\u003e\n\u003cli\u003eDigital communications: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eProof Pressure: 1.6 MPa, 230 PSIG.\u003c\/li\u003e\n\u003cli\u003eLCD Display: Flow rate, Flow rate 0-100%, and total flow\u003c\/li\u003e\n\u003cli\u003eWiring connection to enclosure size: M20 x 1.5\u003c\/li\u003e\n\u003cli\u003eFactory Final QC Test Certificate\u003c\/li\u003e\n\u003cli\u003eIntegral Electronics\u003c\/li\u003e\n\u003cli\u003eElectronics Enclosure: IP65\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003ca title=\"In Stock MAG Meters low price R3\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R3.pdf?224\" target=\"_blank\"\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Mag-Meter-Product-Overview.png?v=1234567890\" alt=\"Mag Meter Product Overview\" loading=\"lazy\"\u003e \u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eInstructions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eCurrent Version:\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca title=\"MAG-Meter-Quick-User-Manual-Style-2\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/QUICK-User_Manual-MAG-Meter-Style2-R_18.docx.pdf?v=1662738582\" target=\"_blank\"\u003eTFM MAG Meter v2 User Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(33, 43, 54); text-decoration: underline;\"\u003e\u003ca title=\"MAG Meter ModBusRTU Manual Style 2\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG_Meter_ModBusRTU_Style2_Rev3.pdf?v=1662738578\" style=\"color: rgb(33, 43, 54); text-decoration: underline;\" target=\"_blank\"\u003eTFM MAG Meter v2 ModBus RTU Manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #212b36;\"\u003eOlder Version:\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" title=\"MAG-Meter-Quick-User-Manual-and-Wiring-Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/QUICK-User_Manual-MAG-Meter-R7.pdf?221\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eTFM MAG Meter v1 User Manual\u003c\/span\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca title=\"MAG-Meter-Quick-User-Manual-Style-2\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/QUICK-User_Manual-MAG-Meter-Style2-R_18.docx.pdf?v=1662738582\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG_Meter_ModBus_RTU_Rev_4.pdf?v=1689292378\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eTFM MAG Meter v1 ModBus RTU Manual\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eFlow Range\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan\u003eThe table below gives a guideline of the nominal maximum GPM for various pipe sizes. \u003cspan style=\"text-decoration: underline;\"\u003e \u003cstrong\u003eFlows in well designed piping systems, to minimize wear and noise, and energy, are typically no more than 10 m\/s max.\u003c\/strong\u003e\u003c\/span\u003e Note these meters can easily go to 12 m\/s for systems, such as high pressure fire fighting systems and blowdown systems. \u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca title=\"TacticalFlow Meter MAG Meter Flow Rate versus Velocity and Pipe size\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Mag-Meter-FlowRate-Chart-TacticalFlowMeter_0.3_to_12mps.png?v=1625240566\"\u003e \u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Mag-Meter-FlowRate-Chart-TacticalFlowMeter_0.3_to_12mps.png?v=1625240566\" alt=\"Tactical Flow Meter MAG Meter Flow Rate Chart versus velocity and pipe size\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003ca title='1\/2\" to 12\" MAG Meter Dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R4.pdf?v=1588134523\"\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MagMeterDimensions1Inch_to_12_Inch.png?v=1588135093\" alt='1\/2\" to 12\" MAG Meter Dimensions' loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eWiring\/Plumbing\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003ca title=\"MAG meter plumbing requirements R3\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R3.pdf?224\" target=\"_blank\"\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG-Meter-Plumbing-Requirements-1.png?v=1543277467\" alt=\"Mag Meter Plumbing Requirements\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"MAG Meter grounding requirements\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R1.pdf?14794767180491946982\" target=\"_blank\"\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG-Meter-Plumbing-Requirements-2.png?v=1543277514\" alt=\"Mag Meter Grounding Requirements\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"background-color: #ffffff;\"\u003e\u003cstrong\u003eIMPORTANT NOTE:\u003c\/strong\u003e \u003cstrong\u003eThis meter is not a \"Loop Powered\" device, unlike almost all temperature and pressure transducers that are loop powered. This meter takes 500 mA to run so you can see that they can not be Loop Powered. It is CRITICAL that 24 VDC is NOT connected to the 4-20 mA signal lines of COM and I+ where COM is connected to the \"low\" side,-, of the 4-20 mA and the I+ is connected to the \"high\" side,+. Your PLC has a mode in it to read these meters that does NOT involve sending power to the meter. These meters are SOURCING the 24 VDC. Connecting 24 VDC to the Current Output lines may void warranty.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/4-20_mA_Simulation_MAG_Meter.png?v=1573511990\" alt=\"How to Simulate 4-20 mA on the MAG Meter.\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003cp\u003eView video above to see how an INSERTION MAG meter is installed, which is DIFFERENT than the flange meters on this product page. Please visit \u003ca title=\"Tactical Flow Meter, Insertion MAG Meter\" href=\"https:\/\/www.tacticalflowmeter.com\/products\/insertion-mag-flow-meter\" target=\"_blank\"\u003eINSERTION MAG\u003c\/a\u003e meter product listing if you discover you need an Insertion Mag Meter.\u003c\/p\u003e\n\u003cp\u003eNote: The following display orientations can be ordered so the user does not have to orient in the field.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Flow_Meter_Display_DIrection_Guide_R1.png?v=1607378321\" alt=\"Flow Meter Display Direction Guide\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/ANSI_CLASS_Flange_Pressure_Ratings_Chart.png?v=1600810814\" alt=\"ANSI Class Rating Chart from Class 150 to Class 2500\" loading=\"lazy\"\u003e\u003c\/h3\u003e\n\u003ch5\u003e\u003cstrong\u003eRetractor\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/INSERTION_METER_WITH_RETRACTOR.png?v=1662351244\" alt=\"Insertion Mag Meter with Retractor\" loading=\"lazy\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch3 class=\"title style-scope ytd-video-primary-info-renderer\"\u003eFlowmeter Retractor \u0026amp; Hot Tap Insertion Meter Retractor\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe HIGH PRESSURE RETRACTOR works with the INSERTION MAG METER or the INSERTION VORTEX METER.  It is smooth as silk and super strong (2,000 PSIG max).  The flexible design will work well with all brands of insertion flow meters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb\u003eHigh Pressure Retractor Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Overall dimensions:  33.5” x 10.8” x 5.6”\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Anodized aluminum brackets and shear box\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Held together with 304 SS hardware\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Smooth 304 SS  ACME screw drive\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e 304 SS guide rails and bearings for increased load capacity\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Power drill actuated - articulation from 0-27 inches\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e 5\/16” hex driver bit included.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cstrong\u003eCut Sheets\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003e \u003ca style=\"color: #2b00ff;\" title=\"MAG Meter dimensions and installation requirements\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R2.pdf?172\" target=\"_blank\"\u003eMAG Meter dimensions\/ Installation requirements\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003cstrong\u003e \u003ca title='12\" MAG Meter Cut Sheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/12__ANSI_RFF_MAG_meter_Carbon_Steel.pdf?v=1592960175\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e12\" ANSI Raised Face 150# Flange MAG Meter \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/12__ANSI_RFF_MAG_meter_Carbon_Steel.pdf?v=1592960175\" title='12\" MAG Meter Cut Sheet' style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003eCut\u003c\/a\u003e\u003ca title='12\" MAG Meter Cut Sheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/12__ANSI_RFF_MAG_meter_Carbon_Steel.pdf?v=1592960175\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003ca title='8\" MAG Meter Cut Sheet Water Flow Meter Spec Sheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/8__ANSI_RFF_MAG_Meter_Carbon_Steel.pdf?v=1611088922\" style=\"color: #005fff;\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong style=\"color: #2b00ff; text-decoration: underline;\"\u003e8\" ANSI Raised Face 150# Flange MAG Meter Cut sheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003cstrong\u003e\u003ca style=\"text-decoration: underline; color: #005fff;\" title='6\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/6__ANSI_RFF_MAG_meter.pdf?788851432150458519\" target=\"_blank\"\u003e6\" ANSI Raised Face 150# Flange MAG Meter Cut sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003cstrong\u003e\u003ca style=\"text-decoration: underline; color: #005fff;\" title='6\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4__304_SS_ANSI_600_RFF_MAG_meter.pdf?222\" target=\"_blank\"\u003e4\" ANSI \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4__304_SS_ANSI_600_RFF_MAG_meter.pdf?222\" title='6\" ANSI Raised Face Flange MAG meter specifications and dimensions' style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003eRaised\u003c\/a\u003e\u003ca style=\"text-decoration: underline; color: #005fff;\" title='6\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4__304_SS_ANSI_600_RFF_MAG_meter.pdf?222\" target=\"_blank\"\u003e Face 600# Flange MAG Meter \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4__304_SS_ANSI_600_RFF_MAG_meter.pdf?222\" title='6\" ANSI Raised Face Flange MAG meter specifications and dimensions' style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003eCut\u003c\/a\u003e\u003ca style=\"text-decoration: underline; color: #005fff;\" title='6\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4__304_SS_ANSI_600_RFF_MAG_meter.pdf?222\" target=\"_blank\"\u003e sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title='4\" 150# ANSI MAG Flow Meter Cut Sheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4in_304_SS_ANSI_4_in_150_RFF_MAG_meter_Rev3.pdf?v=1629331774\"\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003cspan style=\"color: #005fff; text-decoration: underline;\"\u003e\u003cspan\u003e\u003cstrong\u003e4\" 304 SS ANSI 150# RFF MAG meter CutSheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/4__TriClover_MAG_meter_Dimensions.pdf?v=1658250242\"\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003cspan style=\"color: #005fff; text-decoration: underline;\"\u003e\u003cspan\u003e\u003cstrong\u003e4\" TriClover MAG Meter Cut Sheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_3in_304_SS_150_ANSI_3_in_RFF_Remote_MAG_meter_R1.pdf?v=1623698730\" title='3\" 304 SS ANSI 150# RFF Remote MAG meter CutSheet' style=\"color: #005fff;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan\u003e\u003cstrong\u003e3\" 304 SS ANSI 150# RFF Remote MAG meter CutSheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003ca title='3\" 300# ANSI MAG Meter Cut Sheet and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/3__300_ANSI_RFF_MAG_meter_Cut_Sheet.pdf?v=1615490235\" style=\"color: #005fff;\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e3\" 304 SS ANSI 300# RFF MAG meter CutSheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_3__600_ANSI_RFF_MAG_meter.pdf?v=1615513190\" title='3\" 600# ANSI MAG Meter Cut Sheet and dimensions' style=\"color: #005fff;\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e3\" 304 SS ANSI 600# RFF MAG meter CutSheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4in_304_SS_150_4_in_ANSI_RFF_Remote_MAG_meter_R1.pdf?v=1623698730\" title='4\" 304 SS ANSI 150# RFF Remote MAG meter CutSheet' style=\"text-decoration: underline; color: #005fff;\"\u003e4\" 3\u003c\/a\u003e\u003ca title='4\" 304 SS ANSI 150# RFF Remote MAG meter CutSheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4in_304_SS_150_4_in_ANSI_RFF_Remote_MAG_meter_R2_5752dde6-27a8-4f35-81ba-3d0899b21539.pdf?v=1623712496\" style=\"text-decoration: underline; color: #005fff;\"\u003e04 SS ANSI 150# RFF Remote MAG meter CutShee\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4in_304_SS_150_4_in_ANSI_RFF_Remote_MAG_meter_R1.pdf?v=1623698730\" title='4\" 304 SS ANSI 150# RFF Remote MAG meter CutSheet' style=\"text-decoration: underline; color: #005fff;\"\u003et\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_4in_304_SS_150_4_in_ANSI_RFF_Remote_MAG_meter_R1.pdf?v=1623698730\" title='4\" 304 SS ANSI 150# RFF Remote MAG meter CutSheet' style=\"color: #005fff;\"\u003e \u003cspan style=\"text-decoration: underline;\"\u003e \u003c\/span\u003e \u003c\/a\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003ca title='3\" ANSI' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/3__ANSI_RFF_Carbon_Steel_MAG_meter.pdf?11025291778038164151\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e\u003cstrong\u003e3\" ANSI Raised Face 150# Flange MAG Meter Cut sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003cstrong style=\"color: #2b00ff; text-decoration: underline;\"\u003e\u003ca title='3\/4\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_3_4__304_SS_ANSI_RFF_MAG_meter.pdf?v=1589319650\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e3\/4\" ANSI Raised Face 150\u003c\/a\u003e\u003ca title='3\/4\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_3_4__304_SS_ANSI_RFF_MAG_meter.pdf?v=1589319650\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e# Flang\u003c\/a\u003e\u003ca title='3\/4\" ANSI Raised Face Flange MAG meter specifications and dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_3_4__304_SS_ANSI_RFF_MAG_meter.pdf?v=1589319650\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003ee MAG Meter Cut sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003cstrong\u003e\u003ca style=\"text-decoration: underline; color: #005fff;\" title='1 1\/2\" TriClover MAG Meter Cut Sheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/1_1_2__TriClover_MAG_meter_Dimensions.pdf?162\" target=\"_blank\"\u003e1 1\/2\" TriClover MAG Meter Cut Sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_1__304_SS_ANSI_RFF_MAG_meter.pdf?v=1613593059\" title='1\" MAG Meter Cut sheet. List Price $1,600' style=\"color: #005fff;\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan color=\"#2b00ff\"\u003e1\" ANSI Raised Face 150# Flange MAG Meter Cut sheet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_1__304_SS_ANSI_RFF_MAG_meter.pdf?v=1613593059\" title='1\" MAG Meter Cut sheet. List Price $1,600' style=\"color: #005fff;\" target=\"_blank\"\u003e \u003cspan style=\"text-decoration: underline;\"\u003e \u003c\/span\u003e \u003c\/a\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #005fff;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_2__304_SS_150_ANSI_RFF_MAG_meter.pdf?v=1613593391\" title='2\" ANSI Raised Face Flange MAG meter specifications and dimensions' style=\"color: #005fff;\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan\u003e\u003cstrong\u003e2\u003cspan color=\"#2b00ff\"\u003e\" ANSI Raised Face 150# Flange MAG Meter Cut sheet\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003cstrong\u003e\u003ca style=\"text-decoration: underline; color: #005fff;\" title='2\" TriClover MAG Meter Cut Sheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/2__TriClover_MAG_meter_Dimensions.pdf?162\" target=\"_blank\"\u003e2\" TriClover MAG Meter Cut \u003c\/a\u003e\u003ca title='2\" TriClover MAG Meter Cut Sheet' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/2__TriClover_MAG_meter_Dimensions.pdf?162\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003eSheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003ca title='2\" Remote Mount MAG Meter 150# ANSI Flange' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_2__304_SS_150_ANSI_RFF_Remote_MAG_meter.pdf?v=1588811838\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e\u003cstrong\u003e2\" 304 SS ANSI 150# RFF Remote MAG meter CutSheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003ca title=\"Ceramic Al2Oc Wafer Mount MAG Meter Cut Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_Ceramic_Wafer_MAG_Meter.pdf?v=1602534497\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e\u003cstrong\u003eCeramic, Al2O3, Wafer Mount MAG Meter CutSheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline; color: #005fff;\"\u003e\u003ca title=\"Battery Powered MAG Meter Cut Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Battery_Powered_MAG_meter_Cut_Sheet_Rev_2.pdf?208\" style=\"color: #005fff; text-decoration: underline;\" target=\"_blank\"\u003e\u003cstrong\u003eBattery Powered MAG Meter Cut Sheet\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003e\u003ca style=\"color: #2b00ff;\" title=\"3D STEP Files for MAG Meter, Copyrighted 2020 TacticalFlowMeter.com\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAGMeterSTEP-TacticalFlowMeterCopyright-2020.zip?v=1588812413\" target=\"_blank\"\u003eLink to Copyrighted 3D STEP Files\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003e\u003cspan style=\"background-color: #ffff00;\"\u003e\u003c\/span\u003e \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Power_Supplies_Bolts_Gaskets_and_more.pdf?v=1605288973\" title=\"Where to get 24 VDC Power Supplies and flange bolts and gaskets\" style=\"color: #2b00ff; text-decoration: underline;\" target=\"_blank\"\u003eWhere to get Power Supplies, Gaskets, Nuts and Bolts\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch2\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e \u003ca title=\"MAG Meter Fluid Conductivity Chart in µS\/CM\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/CONDUCTIVITY_CHART_MAG_METER.pdf?v=1606413904\" style=\"color: #2b00ff; text-decoration: underline;\" target=\"_blank\"\u003eMAG Meter Conductivity chart for various fluids\u003c\/a\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eRefer to this chart to ensure your fluid has sufficient conductivity to honor Faraday's Law that is the essence of the MAG Meter.\u003c\/p\u003e\n\u003ch5\u003e \u003cstrong\u003eTheory\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003ch2\u003eMAG Meter Theory and Wiring \u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG_Meter_Wiring.png?v=1590102436\" alt=\"MAG Meter Theory and Wiring\" loading=\"lazy\"\u003e\n\u003c\/h2\u003e\n\u003cp\u003eAs an electrically conductive fluid flow passes through the magnetic field in a MAG meter the electrically charged ions accumulate, with negative ions on one side and positive ions on the other.  (Note the MAG meter actually flips the polarity of the magnetic field quickly and the ions move at the speed of light and allow easy measurement) The resulting change in voltage is directly proportional to the velocity of the fluid passing through the inside diameter of the MAG meter. This velocity is used to convert the flow to the flowing volume, usually GPM knowing the measured fluid velocity and the internal pipe diameter.\u003cbr\u003e\u003cbr\u003eInsertion MAG meters utilize a small, localized \"probe\" with magnetic field that is inserted into the pipe. Electrodes cause the positive and negative ions to separate as they do in an inline flow MAG meter. Insertion MAG meters have electrodes located along the probe length to measure average velocity in the measuring location.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cstrong\u003eBattery Powered MAG Meter Specifications\u003c\/strong\u003e \u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Battery_Powered_MAG_Meter_Specifications.png?v=1573189176\" alt=\"Battery Powered MAG Meter Basic Specifications\" loading=\"lazy\"\u003e\n\u003c\/h2\u003e\n\u003cp\u003eIdeally suited for Irrigation MAG meters and Irrigation Flow Meters as they are battery powered.\u003c\/p\u003e\n\u003ch2\u003e\u003cstrong\u003e4-20 mA Connection to Battery Powered MAG meter\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch4\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/BatteryPowered_MAG_Meter_4-20_mA_Connection.png?v=1593707853\" alt=\"Battery Powered MAG Meter 4-20 mA connection (Sink mode)\" loading=\"lazy\"\u003e\u003c\/h4\u003e\n\u003ch5\u003e\u003cstrong\u003eVideos\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch4\u003eBattery Powered MAG Meter User instruction video overview:\u003c\/h4\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"Xr9zAc3Tbp4\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/Xr9zAc3Tbp4\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Battery_Powered_MAG_meter_Cut_Sheet_Rev_2.pdf?208\" title=\"Battery Powered MAG Meter Cut Sheet\" target=\"_blank\"\u003e\u003cspan\u003e\u003cstrong\u003eBattery Powered MAG Meter Cut Sheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003e\u003cstrong\u003eMAG Meter Grounding Ring Sets\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.tacticalflowmeter.com\/products\/grounding-rings-for-mag-meters\" title=\"MAG Meter Grounding Rings\" target=\"_blank\"\u003eVisit Grounding Ring page\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"YL4dhSvo9OQ\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/YL4dhSvo9OQ\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eQuick video above showing how to use the front panel buttons. The SECRET password to CHANGE variables is 03210 where 00521 is for VIEWING only. To get back to NORMAL operation hold the Enter button (the rightmost button) for 3 to 5 seconds. Password to Configure Calibration is 19818\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"_ynfjjTGYbg\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/_ynfjjTGYbg\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eVideo above shows how to set up the Flow Units and Full Scale for those units. Note that this scaling is for driving the 4-20 mA and the frequency output so that the Full Scale value at 20 mA and at full scale Frequency is the number that is set. In this case the 4-20 and the frequency will output 20 mA and 5,000 Hz when the display shows 200 GPM. If the display goes OVER 200 GPM the 4-20 and the Frequency will increase until it \"bumps it's head\" on the maximum value. If the value on the display is GREATER than the value in Full Scale then one would adjust this value to accommodate the anticipated maximum value.\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"c0hLnYA-8Qc\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/c0hLnYA-8Qc\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003eThe video above shows how to set up the meter for Pulse and Frequency and shows how the 4-20 mA is configured. Simulating and validating the 4-20 mA output using the User Interface with 03210 is detailed below. You may ALTER these values (AnalogZero and AnlgRange) using 03210 and they will revert when you exit. Note the 4-20 mA output for this meter is POWERED by the meter. DO NOT connect to a PLC that provides 24 VDC. Connection is made to the 4-20 mA signal using a reading mode just like a Fluke Meter configured to read 4-20 mA DC. The MAG meter provides the 24 VDC for outputting the value to the INPUT of your PLC. Every PLC has the ability to be configured to read this type of 4-20 mA output. (Note: From the main menu the AnalogZero is 49 hits of the UP arrow.) (ADJUSTMENT of the 4-20 Output drive is attained using secret password of 19818 and is risky to use.) \u003cstrong\u003eIf the meter indicates a NEGATIVE flow you may REVERSE the flow using Menu 8: Flow Direction and change it from the indicated value to either the REVERSE or FORWARD value.\u003c\/strong\u003e Note: If the flow indicates a NEGATIVE FLOW number AND you know it is going from LEFT to RIGHT Menu 8 may be used to FLIP the sign. The Flow Direct is a \"switch\" to take care of the \"Right Hand Rule\" with regards to the direction of the current vector in Faraday's Law and does not require the direction to agree with the arrow on the meter. \u003cstrong\u003eIf the meter indicates a  NEGATIVE flow on the display and does not output 4-20 mA it means that  Menu 13: SigmaN Ena can be set to ENABLE to allow the 4-20 to indicate flow in both the + and negative direction. Set Menu 13: SigmaN Ena to DISABLE if you do not want flow to indicate if the flow reverses. In this case the mA will go to 0 mA to indicate reverse flow, but not the magnitude in rate. However, the NEGATIVE Totalizer will account for the negative flow.\u003c\/strong\u003e \u003cstrong\u003eSee video below:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"yK618Tt-ez4\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/yK618Tt-ez4\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cbr\u003eIMPORTANT NOTE:\u003c\/strong\u003e \u003cstrong\u003eThis meter is not a \"Loop Powered\" device, unlike almost all temperature and pressure transducers that are loop powered. This meter takes 500 mA to run so you can see that they can not be Loop Powered. It is CRITICAL that 24 VDC is NOT connected to the 4-20 mA signal lines of COM and I+ where COM is connected to the \"low\" side,-, of the 4-20 mA and the I+ is connected to the \"high\" side,+. Your PLC has a mode in it to read these meters that does NOT involve sending power to the meter. These meters are SOURCING the 24 VDC. Connecting 24 VDC to the Current Output lines may void warranty.\u003c\/strong\u003e The video below shows how to VALIDATE the 4-20 mA signal into your PLC or reading device. Note: If this DOES NOT WORK a likely cause is the power supply does not have enough \"power\" to provide to the meter. The meter requires a MAX of 500 mA so have a power supply that has the capability to DELIVER 500 mA, even on \"start up\" where the inrush current given to the electromagnetic coils can rush over 500mA for a few milliseconds. \u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"sJQ9CYjCwC0\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/sJQ9CYjCwC0\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003eHow to Reset the Totalizer in the MAG Meter. The Password to set the password for the totalizer reset is 10000.  We show Clr Sum Key as the 24'th element in the menu structure. The video shows how to set the Totalizer Reset password to 10000. \u003cbr\u003e\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"pUti8oBQesQ\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/pUti8oBQesQ\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003eHow to use ModBusPoll on the TacticalFlowMeter MAG meter. Use this to ensure your configuration with your PLC is correct.\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"4lquEZuTjh0\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/4lquEZuTjh0\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eIf your flow meter is not showing flows at very low flows. You will use this if you notice the flow meter shows 0 flow when you know there is very low flow. The meter ALSO likely has the Response time set at 10 seconds so it suppresses very low flows further. Refer to \u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Mag-Meter-FlowRate-Chart-TacticalFlowMeter_0.3_to_12mps.png?v=1625240566\"\u003eTHIS chart to find the lowest readable flow on YOUR size flow meter\u003c\/a\u003e \u003c\/strong\u003e. \u003cbr\u003e\u003c\/p\u003e\n\u003ch4\u003eHow to Set the Low Flow Cutoff on the Style 1 MAG meter\u003c\/h4\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"TJ4ieBJo4Sk\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/TJ4ieBJo4Sk\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eHow to Set the Low Flow Cutoff on the Style 2 MAG meter\u003c\/h4\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"22y4sgKYKh8\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/22y4sgKYKh8\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eStyle 2 MAG Meter Interface with 4-20 mA Diagnostics and wiring diagram information.\u003c\/h4\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"Ziu6P72Z-uE\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/Ziu6P72Z-uE\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eInsertion MAG Meter overview.\u003c\/h4\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"gdFMiz4bo20\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/gdFMiz4bo20\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eView video above to see how an INSERTION MAG meter is installed, which is DIFFERENT than the flange meters on this product page. Please visit \u003ca href=\"https:\/\/www.tacticalflowmeter.com\/products\/insertion-mag-flow-meter\" title=\"Tactical Flow Meter, Insertion MAG Meter\" target=\"_blank\"\u003eINSERTION MAG\u003c\/a\u003e meter product listing if you discover you need an Insertion Mag Meter. Note: The following display orientations can be ordered so the user does not have to orient in the field.\u003c\/h4\u003e\n\u003cp\u003eLearn why Insertion meters only need to be inserted less than 5\" in larger pipes by watching the video below....\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"rk8rcwH5muM\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/rk8rcwH5muM\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eDiscover where the classical \"1\/8 D Insertion Depth\" for location of an insertion meter sensor comes from. We show fluid mechanics data showing WHY the guidance if the pipe Diameter is greater than 10\" the insertion depth only needs to be 5\"... An Approximation. Above we discuss the EXACT value required to follow \"\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Flow_Profile_From_Miller_Chapter_5.pdf?v=1605202101\" title=\"Mag Meter Insertion Depth at 1\/8th pipe Diameter\" target=\"_blank\"\u003eMiller Best Practices\u003c\/a\u003e\u003c\/strong\u003e\".\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"WZnWhWXi1f0\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/WZnWhWXi1f0\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eView video above to see examples of LabVIEW programs we supply to Universities and some customers to assist in getting their projects online.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"FWHHf9xGZnE\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/img.youtube.com\/vi\/FWHHf9xGZnE\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003eVideo above shows the MAG meter configuration program\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhat causes a SYS error or SYS alarm on the MAG meter?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eSYS means there is a System alarm. The reasons for it may be from the following: \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e1. No water in the pipe line... or\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e2. pipe line is not 100% filled with water... or\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e3. The measuring electrodes are not covered by the water... or\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e 4. The fluid\/water is too pure, the conductivity is less than 15 μs\/cm... or\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e5. Water has entered the sensor electronics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e Note: This alarm can be disabled (Menu 24) as there is no harm in running the meter with no fluid. The purpose of the alarm is to \"latch\" and show itself if any of the above instances may have occurred. \u003c\/p\u003e","brand":"Tactical Flow Meter","offers":[{"title":"1\/2\" \/ ANSI 150#","offer_id":41811540541609,"sku":"Mag-AN-1_2","price":1500.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ TriClover Sanitary","offer_id":41811540607145,"sku":"Mag-TC-1_2","price":1600.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ ANSI 150#","offer_id":41811540639913,"sku":"Mag-AN-1","price":1550.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ TriClover Sanitary","offer_id":41811540705449,"sku":"Mag-TC-1","price":1650.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ ANSI 150#","offer_id":44993676476585,"sku":"Mag-AN-1_1_2","price":1600.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ TriClover Sanitary","offer_id":44993676509353,"sku":"Mag-TC-1_1_2","price":1700.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ ANSI 150#","offer_id":41811540738217,"sku":"Mag-AN-2","price":1700.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ TriClover Sanitary","offer_id":41811540803753,"sku":"Mag-TC-2","price":1800.0,"currency_code":"USD","in_stock":true},{"title":"2 1\/2\" \/ ANSI 150#","offer_id":44993676542121,"sku":"Mag-AN-2_1_2","price":1750.0,"currency_code":"USD","in_stock":true},{"title":"2 1\/2\" \/ TriClover Sanitary","offer_id":44993676574889,"sku":"Mag-TC-2_1_2","price":1850.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ ANSI 150#","offer_id":41811540836521,"sku":"Mag-AN-3","price":1850.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ TriClover Sanitary","offer_id":41811540902057,"sku":"Mag-TC-3","price":1950.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ ANSI 150#","offer_id":41811540934825,"sku":"Mag-AN-4","price":1950.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ TriClover Sanitary","offer_id":41811541000361,"sku":"Mag-TC-4","price":2050.0,"currency_code":"USD","in_stock":true},{"title":"6\" ANSI ONLY \/ ANSI 150#","offer_id":41811541033129,"sku":"Mag-AN-6","price":2300.0,"currency_code":"USD","in_stock":true},{"title":"8\" ANSI ONLY \/ ANSI 150#","offer_id":41811541098665,"sku":"Mag-AN-8","price":2700.0,"currency_code":"USD","in_stock":true},{"title":"10\" ANSI ONLY \/ ANSI 150#","offer_id":41811541164201,"sku":"Mag-AN-10","price":3650.0,"currency_code":"USD","in_stock":true},{"title":"12\" ANSI ONLY \/ ANSI 150#","offer_id":41811541229737,"sku":"Mag-AN-12","price":4750.0,"currency_code":"USD","in_stock":true},{"title":"6\" and up Insertion +\/- 1.0% \/ ANSI 150#","offer_id":46413680148649,"sku":"Mag-Insertion-1_0-1","price":3600.0,"currency_code":"USD","in_stock":true},{"title":"6\" to 96\" Insertion +\/- 2.0% \/ ANSI 150#","offer_id":46413154517161,"sku":"Mag-Insertion-2_0-1","price":3300.0,"currency_code":"USD","in_stock":true},{"title":"6\" to 96\" Insertion +\/- 2.0% with High Pressure Retractor \/ ANSI 150#","offer_id":46413234045097,"sku":"Mag-Insertion-Retractor-2_0-1","price":4800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG-Meter-TacticalFlowMeter.webp?v=1758754506"},{"product_id":"insertion-magnetic-flow-meter-2-0-accuracy","title":"Insertion Magnetic Flow Meter \u003cbr\u003efor Liquid Flow \u003cbr\u003e6\" to 96\" \u003cbr\u003e+\/- 2.0%","description":"\u003cp\u003eInsertion MAG Flow Meter with or without High Pressure Retractor. Select the option you require.\u003c\/p\u003e\n\u003cp\u003eThe TFM Insertion Mag Meter operates based on Faraday’s Law of electromagnetic induction: as flow velocity of a liquid increases through the magnetic field generated by the sensor head of the flow meter, electrodes measure the voltage increase to calculate flow. … The voltage readings are sampled \u0026amp; averaged.\u003c\/p\u003e\n\u003cp\u003eInsertion Mag meter for liquids, slurries shipping from stock \u0026amp; configured for you.\u003c\/p\u003e\n\u003cp\u003eEASY to use Insertion MAG Meters. Check our stock and prices that beats our competition.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv class=\"product-bullet-list\"\u003e\n\u003cul\u003e\n\u003cli\u003eWetted Materials: Teflon \u0026amp; 316 SS\u003c\/li\u003e\n\u003cli\u003eFlow Body Material: 304 SS\u003c\/li\u003e\n\u003cli\u003eFlow Rate: 100 kg\/h to 200,000 kg\/h relative to water\u003c\/li\u003e\n\u003cli\u003eAccuracy:\n\u003cul\u003e\n\u003cli\u003e+\/- 2.0% of reading in water.\u003c\/li\u003e\n\u003cli\u003eLowest measuring velocity is 0.5 m\/s, or 100 fpm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eRepeatability of +\/- 0.05% of reading\u003c\/li\u003e\n\u003cli\u003ePipe Size:\n\u003cul\u003e\n\u003cli\u003eInsertion for 6\" to 96\" Diameter pipe\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLCD Display\u003c\/li\u003e\n\u003cli\u003eTemperature:\n\u003cul\u003e\n\u003cli\u003eGas: -58°F (-50°C) to 350°F (180°C)\u003c\/li\u003e\n\u003cli\u003eAmbient: 14°F (-10°C) to 140°F (60°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Requirement: Order either 24 VDC or 85-220 VAC, 15 Watts maximum;\u003c\/li\u003e\n\u003cli\u003eOutput signals: Modbus RTU, 4–20 mA, and 0-10 KHz for flow rate indication\u003c\/li\u003e\n\u003cli\u003eDigital communications: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eProof Pressure: 230 PSIG, 1.6 MPa.\u003c\/li\u003e\n\u003cli\u003eDisplay: Flow rate, Flow Rate 0-100%, and Total flow\u003c\/li\u003e\n\u003cli\u003eWiring connection to enclosure size: M20 x 1.5\u003c\/li\u003e\n\u003cli\u003eFactory Final QC Test Certificate\u003c\/li\u003e\n\u003cli\u003eIntegral Electronics installation\u003c\/li\u003e\n\u003cli\u003eElectronics Enclosure: NEMA 4X \/ IP67\u003c\/li\u003e\n\u003cli\u003eConductivity \u0026gt; 5 microSiemens\/cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\n\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters.pdf?5036035778741373374\" title=\"In Stock MAG Meters low price\" target=\"_blank\"\u003e\u003cimg alt=\"Mag Meter Product Overview\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Mag-Meter-Product-Overview_2048x2048.png?v=1543259636\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eFlow Range\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eThe image below gives a guideline of the nominal maximum GPM for various pipe sizes \u003cimg alt=\"Pipe sizes versus GPM guidelines\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/GPM-FlowRates_large.jpg?v=1544056504\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG-Meter-Display-Description_large.png?v=1529382214\" alt=\"MAG Flow Meter Display\"\u003e \u003cbr\u003eFeatures LARGE LCD display, shows the Instantaneous Flow Rate, Total Flow, in user selectable units.\u003c\/p\u003e\n\u003cp\u003eWhere to get Power Supplies, Gaskets, Nuts and Bolts \u003ca title=\"Where to get 24 VDC Power Supplies and flange bolts and gaskets\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Power_Supplies_Bolts_Gaskets_and_more.pdf?v=1605288973\" target=\"_blank\"\u003eLink\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eNote: The following display orientations can be ordered so the user does not have to orient in the field.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Flow_Meter_Display_DIrection_Guide_R1_600x600.png?v=1607378321\" alt=\"MAG Meter flow Orientation guide\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eRetractor\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003e\u003cspan style=\"font-weight: 400;\"\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eHIGH PRESSURE  INSERTION FLOW METER RETRACTOR\u003c\/span\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/INSERTION_METER_WITH_RETRACTOR_480x480.png?v=1662351244\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003ch3 class=\"title style-scope ytd-video-primary-info-renderer\"\u003eFlowmeter Retractor \u0026amp; Hot Tap Insertion Meter Retractor\u003c\/h3\u003e\n\u003cp\u003e\u003cspan\u003eThe HIGH PRESSURE RETRACTOR works with the INSERTION MAG METER or the INSERTION VORTEX METER.  It is smooth as silk and super strong (2,000 PSIG max).  The flexible design will work well with all brands of insertion flow meters.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cbr\u003e\u003c\/span\u003e\u003cb\u003eHigh Pressure Retractor Specifications\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Overall dimensions:  33.5” x 10.8” x 5.6”\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Anodized aluminum brackets and shear box\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Held together with 304 SS hardware\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Smooth 304 SS  ACME screw drive\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e 304 SS guide rails and bearings for increased load capacity\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e Power drill actuated - articulation from 0-27 inches\u003cbr\u003e\u003c\/span\u003e\u003ca href=\"https:\/\/coolsymbol.com\/copy\/Black_Four_Pointed_Star_Symbol_%E2%9C%A6\"\u003e\u003cspan\u003e✦\u003c\/span\u003e\u003c\/a\u003e\u003cspan\u003e 5\/16” hex driver bit included.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch5\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eConsult factory for custom installation drawings for your Insertion MAG Meter requirements.\u003c\/p\u003e\n\u003ch3\u003eINSERTION MAG Meter Dimensions\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/InsertionDepth_large.jpg?v=1565382278\" alt=\"\" width=\"437\" height=\"638\"\u003e\u003cbr\u003e\u003cbr\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/InsertionSideView_large.jpg?v=1565382292\" alt=\"\" width=\"431\" height=\"594\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/Insertion_Dimensions_large.jpg?v=1565382304\" alt=\"\" width=\"588\" height=\"561\"\u003e\u003c\/p\u003e\n\u003cp\u003eNote: The image above allows one to determine the Hot Tap or Corp. Stop, Corporation Stop, requirements ad the 3.4\" long \"sensing region\" can be retracted within the 7.0\" long tube that is shown BELOW the Ball Valve in the above image. Frequently, customers utilize their own Ball Valve left behind from the Hot Tap or Corp. Stop rig that drilled into the \"live\" pipe. It is VERY important to note that the sensing point only needs to be inserted 1\/8'th of the diameter into the flowing stream, IDEALLY, from the SIDE rather than the Top of Bottom as the Bottom is the least ideal location due to buildup. See the Fluid Mechanics video and paper BELOW explaining WHY this is true.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R2.pdf?172\" title=\"MAG Meter dimensions and installation requirements\" target=\"_blank\"\u003eMAG Meter dimensions\/ Installation requirements\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003ePlumbing\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eInsertion and Flanged MAG Meter Installation requirements:\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters.pdf?5036035778741373374\" title=\"MAG meter plumbing requirements\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MAG-Meter-Plumbing-Requirements-1_1024x1024.png?v=1543277467\" alt=\"Mag Meter Plumbing Requirements\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eCut Sheet\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/6__ANSI_RFF_MAG_meter.pdf?788851432150458519\" title='6\" ANSI Raised Face Flange MAG meter specifications and dimensions' target=\"_blank\"\u003e6\" ANSI Raised Face Flange MAG Meter Cut sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eVideos\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv id=\"tab-5\" class=\"tab\"\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/YuhwixeAP14\" width=\"530\" height=\"298\" style=\"max-width: 100%;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/YL4dhSvo9OQ\" width=\"530\" height=\"298\" style=\"max-width: 100%;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003eQuick video showing how to use the front panel buttons.\u003c\/p\u003e\n\u003cp\u003eLearn why Insertion meters only need to be inserted less than 5\" in larger pipes by watching the video below....\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/rk8rcwH5muM\" width=\"530\" height=\"298\" style=\"max-width: 100%;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003eDiscover where the classical \"1\/8 D Insertion Depth\" for location of an insertion meter sensor comes from. We show fluid mechanics data showing WHY the guidance if the pipe Diameter is greater than 10\" the insertion depth only needs to be 5\"... An Approximation. Above we discuss the EXACT value required to follow \"\u003cstrong\u003e\u003ca title=\"Mag Meter Insertion Depth at 1\/8th pipe Diameter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Flow_Profile_From_Miller_Chapter_5.pdf?v=1605202101\" target=\"_blank\"\u003eMiller Best Practices\u003c\/a\u003e\u003c\/strong\u003e\".\u003c\/p\u003e\n\u003cp\u003e\u003ciframe title=\"YouTube video player\" src=\"https:\/\/www.youtube.com\/embed\/gdFMiz4bo20\" width=\"530\" height=\"298\" style=\"max-width: 100%;\"\u003e\u003c\/iframe\u003e\u003c\/p\u003e\n\u003cp\u003eView video above to see how an INSERTION MAG meter is installed, which is DIFFERENT than conventional flange meters. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tactical Flow Meter","offers":[{"title":"Insertion MAG Meter Flow Meter","offer_id":42539541266601,"sku":"Mag-Insertion-2","price":3300.0,"currency_code":"USD","in_stock":true},{"title":"Insertion MAG Meter Flow Meter with High Pressure Retractor","offer_id":42539541299369,"sku":"Mag-Insertion-Retractor-2","price":4800.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM_Mag_Insertion1_Front.webp?v=1758822505"},{"product_id":"ultrasonic-liquid-flow-meter-with-thermal-energy-btu-capability","title":"Clamp On Ultrasonic Flow Meter \u003cbr\u003efor Liquid Flow \u003cbr\u003e0.6\" to 228\" \u003cbr\u003e+\/- 1.0%","description":"\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eUltrasonic flowmeters use sound waves to determine the velocity of a fluid flowing in a pipe. At no flow conditions, the frequencies of an ultrasonic wave transmitted into a pipe \u0026amp; its reflections from the fluid are the same. The Ultrasonic Heat Meter allows for collection of BTU measurements for sub metering and billing.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eUltrasonic flowmeters for liquids, slurries ship from stock \u0026amp; configured for you OEM OK\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eEASY to use Clamp on Ultrasonic Meters. Check our stock \u0026amp; prices that beats our competition.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFeatures LARGE LCD display, shows the Instantaneous Flow Rate, Total Flow, in user-selectable units. One of the first Ultrasonic flow meters with a data logger. Both 24 VDC and universal AC power capability in an Ultrasonic Heat Meter and Ultrasonic Flow Meter.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!--split--\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003eClamp On Ultrasonic Flow Meter Specifications\u003c\/h3\u003e\n\u003cdiv class=\"product-bullet-list\"\u003e\n\u003cul\u003e\n\u003cli\u003eTransducer material: Aluminum and 304 SS\u003c\/li\u003e\n\u003cli\u003eMedium: Any acoustically conductive liquid with less than 5% air bubbles or solids\u003c\/li\u003e\n\u003cli\u003eFlow Range: Supports velocities up to  40 f\/s or 12 m\/s\u003c\/li\u003e\n\u003cli\u003eAccuracy: ±1%  from 0.15 to 40 f\/s (0.05 to 12 m\/s)\u003c\/li\u003e\n\u003cli\u003eResolution: 0.01 ft\/s (0.00025 m\/s)\u003c\/li\u003e\n\u003cli\u003eResponse time: 150 ms measuring cycle typical\u003c\/li\u003e\n\u003cli\u003ePipe Size: \n\u003cul\u003e\n\u003cli\u003e0.6” to 228” \u003c\/li\u003e\n\u003cli\u003eSmallest pipe\/tube:(1.125 OD with .05 wall with N or W Mounting)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eTemperature: - 20 - 110 ℃\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCable length: 15’\u003c\/li\u003e\n\u003cli\u003eTransducer Frequency: 1 MHz\u003c\/li\u003e\n\u003cli\u003eClamp-on transducers: encapsulated design IP68\n\u003cul\u003e\n\u003cli\u003eStd Temp Spec for Blue Transmitters 194 F (90 C)\u003c\/li\u003e\n\u003cli\u003eStd Temp Spec for Black Transmitters 320 F (160 C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eEnclosure Grade: IP65\u003c\/li\u003e\n\u003cli\u003eDisplay LCD Screen\u003c\/li\u003e\n\u003cli\u003ePower Supply: Set up to use either 24VDC or a 86-240 VAC Universal Power Supply. Only one at a time. Consumes 500 mA max\u003c\/li\u003e\n\u003cli\u003eOutput: 4-20mA + 0-10K Hz + Standard ModBus RTU Communication protocol\u003c\/li\u003e\n\u003cli\u003eNote: For 1 to 5 VDC output, add 250 Ohm resistor to 4 to 20 mA loop\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eProduct Line\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003eMAG Meter Complimentary Product line\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Mag-Meter-Product-Overview_2048x2048.png?v=1543259636\" alt=\"Mag Meter Product Overview\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eInstructions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Quick-ultrasonic-flow-meter-Style_2-user-Manual-R17.pdf?v=1676223339\" title=\"Quick User Manual Ultrasonic Flow Meter\"\u003eTFM Clamp-On Ultrasonic Manual v2\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Quick_ultrasonic_flow_meter_user_Manual_R9.pdf?v=1547694248\" title=\"Quick Ultrasonic Manual Rev 9\" target=\"_blank\"\u003eTFM Clamp-on Ultrasonic Manual v1\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan style=\"background-color: #ffff00;\"\u003e\u003cstrong\u003eWhere to get Power Supplies, Gaskets, Nuts and Bolts \u003cspan style=\"text-decoration: underline; color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Power_Supplies_Bolts_Gaskets_and_more.pdf?v=1605288973\" title=\"Where to get 24 VDC Power Supplies and flange bolts and gaskets\" style=\"color: #2b00ff; text-decoration: underline;\" target=\"_blank\"\u003eLink\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch5\u003e\u003cstrong\u003ePlumbing\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eUltrasonic Meter Transducer Installation requirements:\u003c\/strong\u003e On this flow meter, as well as of all flow meters, it is CRITICAL that the pipe remains full at all times. This meter requires that the flow remain relatively consistent. Note 10 diameters clear of obstruction upstream and 5 diameters down. As well, it is important to ensure the LCD Display is not out in the Direct Sun, provide a shade cover for the LCD so that it will retain the high contrast required for viewing the values.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Ultrasonic flow meter installation guide\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Floe_Meter_Installation_Guide_grande.png?v=1547757634\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Ultrasonic Flow Meter Installation Guide 2\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Floe_Meter_Installation_Guide_2_grande.png?v=1547757673\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Pipe ID and OD Chart by Tioga\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/pipe-chart-Tioga.pdf?5006539391016245466\" target=\"_blank\"\u003ePipe ID and OD Chart\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eTheory\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003ca title=\"PDF of How Ultrasonic Flow Meters Work\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Flow_Sensor_Principle_Simplified_R2.pdf?v=1663606812\"\u003ePDF of How Ultrasonic Flow Meters Work\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eRemote Totalizer\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch2\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/How_to_Connect_Ultrasonic_to_RedLion_CUB5R000_Rev_1.pdf?v=1615424733\" title=\"How to connect a RedLion CUB5R000 to an Ultrasonic FLow Meter for Totalizing\" target=\"_blank\"\u003eHow to Connect a RedLion CUB5R000 for Remote totalizing.\u003cbr\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/h2\u003e\n\u003ch5\u003e\u003cstrong\u003eInstallation\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch2\u003e\u003ca title=\"How to install clamp on ultrasonic transducers\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/How_to_Connect_the_Ultrasonic_Clamp_On_Transducers_Rev_2.pdf?v=1589481060\" target=\"_blank\"\u003eHow to Install Ultrasonic Clamp On Transducers\u003c\/a\u003e\u003c\/h2\u003e\n\u003cp\u003eClamping system for pipes larger than 10\" OD. Install by securing ends with clamps WITHOUT the transmitter and then stretch the nylon coated SS wire over the transmitter. BE SURE to grind a CLEAN area for the transmitter to conduct the sound AND use the Acoustic Coupling Grease on the transmitter\/pipe interface.\u003cbr\u003e\u003cimg alt='Wire Rope with Spring clamping system for piped over 10\" OD' src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Wire-Rope-Clamp-For-Ultrasonic-Flow-Meter_600x600.png?v=1580861605\" loading=\"lazy\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eNote how strap is used.\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Ultrasonic Strap Using Spring\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/UltrasonicStrap_480x480.png?v=1581394791\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eAcoustic Grease\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch4\u003eACOUSTIC COUPLING GREASE SPECIFICATIONS:\u003c\/h4\u003e\n\u003cp\u003eDow Corning Product Name: MOLYKOTE™ BR-2 Plus High Performance Grease\u003c\/p\u003e\n\u003cp\u003eThis material is designed to remain in a gel like form to increase the acoustic coupling of the ultrasonic transducers to the pipe. This material works from -57 to 204 Degrees C which is above the specs of the transducers.\u003c\/p\u003e\n\u003cp\u003eHere is a source to buy it: MSC # \u003ca href=\"https:\/\/www.mscdirect.com\/product\/details\/31735293\" title=\"Dow Corning 111 MolyKote\"\u003e31735293\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003eIn a \"pinch\" one could use KY Jelly from the drug store but it is runny. The goal is to have a material that will not have bubbles in it and provides good sonic coupling. Air bubbles are the \"enemy\" of ultrasonic transducers. Using traditional Silicone sealant, such as that used for sealing windows, could also be used in an emergency but you MUST assure there are no air bubbles.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eSound Speed\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eSound speed of various materials:\u003ca title=\"Sound Speed of Various Materials\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/SoundSpeedMaterials.png?3247770073703420262\" target=\"_blank\"\u003e\u003cimg alt=\"Sound Speed Various Materials\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/SoundSpeedMaterials_1024x1024.png?v=1550121890\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e For Fluids that are NOT already Pre Programmed into the Ultrasonic meter you will want to enter in the Sound Speed and Viscosity at the temperature of 20 Degrees C as this is the REFERENCE condition used for the math in the flow meter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant notes on the use of Clamp On Meters of all brands:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eWhile it is compelling to utilize these meters because of their ease of installation it is critical that the pipe material, thickness and ID are well known. Many times older pipes can have significant corrosion reducing the inner diameter to such a level that the sonic energy can not penetrate. Frequently banging on the pipe with a double jack can remedy and remove large \"mushroom like\" growths it can not remove long term built up scale that tends to absorb energy. Banging on some piping systems is NOT an option because it can break or cause a leak. We can not guarantee that a Clamp On Meter is ideal for the installation if the internal condition of the pipe is unknown. We will be happy to provide consultation to give ideas on how to measure flows in such conditions but can not be held to task should the internals of the pipe not be verifiable. Generally we will not refund the purchase price on a system where the pipe condition is difficult to obtain.\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eCheat Sheet\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003ca style=\"text-decoration: underline; color: #2b00ff;\" title=\"Ultrasonic Flow Meter Quick User Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Quick_ultrasonic_flow_meter_Style_2_user_Manual_R16.pdf?v=1591375140\" target=\"_blank\"\u003eQuick Ultrasonic Instruction Manual, Style 2\u003c\/a\u003e \u003ca style=\"text-decoration: underline; color: #2b00ff;\" title=\"Ultrasonic Installing Cheat Sheet, Style 2\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Meter_Setup_Cheat_Sheet_Rev_7.pdf?177\" target=\"_blank\"\u003eUltrasonic Installing Cheat Sheet, Style 2\u003c\/a\u003e\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Meter_Setup_Cheat_Sheet_Rev_7.pdf?177\" title=\"Ultrasonic Flow Meter Cheat Sheet\"\u003e\u003cimg style=\"float: none;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Flow_Meter_Cheat_Sheet_1024x1024.png?v=1548989077\" alt=\"Ultrasonic Flow Meter Cheat Sheet\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5 style=\"text-align: left;\"\u003e\u003cstrong\u003eVideos\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003e\u003cstrong\u003eHELPFUL QUICK NOTES: Menu 90 shows Signal Strength and Menu 00 shows main flow rate and total.\u003c\/strong\u003e Frequently, fine tuning may be had by invoking Menu 90 and making small movements of one of the transducers to get the highest signal. Numbers over 80% are considered very good. Also set menu 40, the Filter Coefficient, (We could call this the time constant or response time), with Menu 40 to 1 second to make the meter respond quickly. Then, put back to 4 seconds and save with Menu 26 and hit enter twice. Menu 45 is for entering a K-Factor, this would be handy if you KNOW the flow is 90 when it says 100. In this case a K-Factor of 0.9 would remedy it. (Ideally the distances and pipe thickness\/material would be corrected but this is easier). Menu 70 and 71 allow LCD Display on time and contrast respectively. Note for Password Menu 47 System Lock unlock code is 8758 \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003ePASSWORD = 8758\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003eK-Factor\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003eThere is a Scale or K-Factor at Menu 45 that you may wish to invoke if you know a flow to be 1.10 units and we say is is 1.00 units then you can adjust Menu 45 to 1.1 to have the meter agree with a standard you believe to be true and correct. After setting this value invoke Menu 25 with two Enter hits and then get back to the main menu with menu 00. Note: The Scale, or K-Factor can go from 0.5 to 1.5.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003eEnergy Meter BTU Meter notes\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eUse ModBus RTU to read register 121 (Positive energy accumulator for billing) as an IEEE-754 float in ABCD Byte order\u003c\/span\u003e \u003cspan style=\"font-weight: 400;\"\u003e for the energy value in GJ (Giga Joules) \u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eNote:947,817 BTU = 1 Gj\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eSelect Menu 5 to view Energy values, Menu 6 shows Delta T.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eSelect Menu 84 to configure Energy Meter settings.\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eReset totalizers with Menu 37\u003c\/span\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003e§3.1.6 Validating meter function.\u003c\/strong\u003e\u003cbr\u003eEntering a pipe outer diameter (Menu 11) of zero, results in the display to show the flow velocity: 1.2345678m\/s (4.0504ft\/s) [use down arrow to view], flow rate= will vary, and display “R”status on Menu 00. Inputting a set value in M44 will change the flow rate output. Use this function to test of the flow meter and network software without having to connect the transducers. If they are connected the flow rate may be + or - \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003eNote: Menu 44 allows setting up a ZERO value so that you can simulate flow. Entering a - (negative) value allows the flow to indicate positive. Be sure to put Menu 44 back to 0 when done simulating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSimple Overview how Ultrasonic Flow Meters Work. See the PDF below as well.\u003cbr\u003e\u003ca title=\"PDF of How Ultrasonic Flow Meters Work\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Flow_Sensor_Principle_Simplified_R2.pdf?v=1663606812\"\u003ePDF of How Ultrasonic Flow Meters Work\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"UtgkIFGB358\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/UtgkIFGB358\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eSuper Simple example for parsing data from ModBus showing a fixed value and a changing value.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"WURWJ3lkDQQ\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/WURWJ3lkDQQ\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eUltrasonic Meter setup verification and overview of menus for \u003cstrong\u003eDOSING\u003c\/strong\u003e or \u003cstrong\u003eMETERING\u003c\/strong\u003e functions. The video below called \"\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eVideo showing How to connect 4-20 mA on the Ultrasonic Flow Meter\u003c\/strong\u003e\" shows more details about pipe type and fluid selection in the 4-20 mA. Please watch this quick video and do not forget about Menu 26.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"1LRB8Lk5WYc\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/1LRB8Lk5WYc\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eHow to make a Batch Controller with an Ultrasonic Flow Meter:\u003cbr\u003eNote: Menu 78 allows you to select the OCT (Open Collector Transistor) and\/or the Relay Output contact closure at pins 30 and 31 under menu 79 \u003cstrong\u003eRELAY Output Setup.\u003c\/strong\u003e  Use Selection \u003cstrong\u003e8. Batch Controller\u003c\/strong\u003e Then, ensure Batch Trigger Select is on \u003cstrong\u003e0. Key Pressing\u003c\/strong\u003e.  CYcle through Menu 78 to see OCT Output [78 indicate 8. Batch controller, then hit the down arrow to confirm Relay Output Setup 8. Batch Controller then hit the down arrow to confirm Batch Trigger Select set to 8. Key Pressing to duplicate what is shown in the video.  Select how many gallons you wish to batch with Menu 81 and if it is already set hit ENT 3 times to start the batch. The batch can also be initiated with the OCT and with ModBus. Remember: Select Menu 26 and hit ENT TWICE after making changes to SAVE your settings.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"pKgFyOrjLuo\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/pKgFyOrjLuo\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eVideo showing How to connect 4-20 mA on the Ultrasonic Flow Meter\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"DGmE37iVNCA\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/DGmE37iVNCA\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Flow_Meter_Wiring_4-20_mA_large.png?v=1564089241\" alt=\"Ultrasonic Flow Meter Wiring for 4-20 mA output\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003eHow to Factory Reset the Meter Values if you discover unknown variables were changed. Note: Doing so retains the timing calibration elements but reverts to factory values that require selecting the language, units, transducer type, and all the pipe and fluid settings. We show this using Menu 37 twice, once to reset and the next to select the language, and then using Menu 30 to select the units, then 23 for the transducer type, then 70 to have the LCD Backlight stay on 999 seconds, and then on to menu 11 and the associated menus such as 77, we do not show menu 55 and associated menus for the 4-20 output. Remember Menu 26 TWICE to save your changes. Use the \u003ca title=\"Cheat Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Meter_Setup_Cheat_Sheet_Rev_7.pdf?v=1613684951\" target=\"_blank\"\u003eCheat Sheet\u003c\/a\u003e to configure your meter as required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"V4mYT-MHojM\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/V4mYT-MHojM\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eHow to Linearize the Ultrasonic Flow Meter. Menu 48 and enter password 1111 to start and enter how many points you will use. We show 7 points in this example. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"l8VVS19TIPc\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/l8VVS19TIPc\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Tactical Flow Meter","offers":[{"title":"TS-1 2\" to 4\" Pipe \/ None","offer_id":42082339160233,"sku":"ULTRA-01","price":1900.0,"currency_code":"USD","in_stock":true},{"title":"TS-1 2\" to 4\" Pipe \/ 1 set 100 Ohm Platinum 385 Temp Sensors for BTU","offer_id":42655859540137,"sku":"ULTRA-01-T","price":2400.0,"currency_code":"USD","in_stock":true},{"title":"TM-1 4\"to 24\" Pipe \/ None","offer_id":42082339193001,"sku":"ULTRA-02","price":1950.0,"currency_code":"USD","in_stock":true},{"title":"TM-1 4\"to 24\" Pipe \/ 1 set 100 Ohm Platinum 385 Temp Sensors for BTU","offer_id":42655859572905,"sku":"ULTRA-02-T","price":2450.0,"currency_code":"USD","in_stock":true},{"title":"TL-1 11\" to 48\" Pipe \/ None","offer_id":42082339225769,"sku":"ULTRA-03","price":1975.0,"currency_code":"USD","in_stock":true},{"title":"TL-1 11\" to 48\" Pipe \/ 1 set 100 Ohm Platinum 385 Temp Sensors for BTU","offer_id":42655859605673,"sku":"ULTRA-03-T","price":2475.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/Ultrasonic_Flow_Meter_Electronics_Style_2.png?v=1600446634"},{"product_id":"multivariable-vortex-mass-flow-meter","title":"Multivariable Vortex Flow Meter \u003cbr\u003efor Liquid Flow and Gas Flow \u003cbr\u003e1\/2\" to 72\"","description":"\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eA Vortex flow meter is a flow measurement device best suited for applications where the introduction of moving parts presents problems. They are available in industrial grade, brass or all plastic construction.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eVortex flow meters work well with clean liquids, gases, and steam because they provide accurate, reliable measurements in applications with stable, non-viscous, single-phase flow.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eVortex flow meters are well-suited for steam applications because they handle high temperatures and pressures and provide accurate volumetric or mass flow measurements when paired with temperature and pressure compensation. Their robust design resists wear from dry or wet steam, making them reliable for saturated and superheated steam in industrial systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eVortex flow meter for liquids, steam \u0026amp; gas shipping from stock \u0026amp; configured for you. EASY to use Industrial Vortex Meters. Check our stock and prices that beats our competitors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c!--split--\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003eMultivariable Vortex Flow Meter Specifications\u003c\/h3\u003e\n\u003cdiv class=\"product-bullet-list\"\u003e\n\u003cul\u003e\n\u003cli\u003eWetted Materials: 304 SS\u003c\/li\u003e\n\u003cli\u003eFlow Range:\n\u003cul\u003e\n\u003cli\u003eLiquid: \u003cspan\u003e0.5 fps - 33 fps.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003eGas: Large Pipes 5 fps - 213 fps, Small Pipes 13 fps - 213 fps.\u003c\/li\u003e\n\u003cli\u003eSteam: Large Pipes 5 fps - 230 fps, Small Pipes 13 fps - 230 fps.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/- 1% of reading\u003c\/li\u003e\n\u003cli\u003eRepeatability: +\/- 0.05% of reading\u003c\/li\u003e\n\u003cli\u003ePipe Size:\n\u003cul\u003e\n\u003cli\u003eInline: 1\/2\" to 4\" 150# ANSI Flange Connections, Up to 12\" available custom.\u003c\/li\u003e\n\u003cli\u003eInsertion: 8\" to 72\"\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLCD Display\u003c\/li\u003e\n\u003cli\u003eTemperature Accuracy +\/- 1 Deg C\u003c\/li\u003e\n\u003cli\u003eTemperature:\n\u003cul\u003e\n\u003cli\u003eGas: -40°F (-40°C) to 482°F (250°C)\u003c\/li\u003e\n\u003cli\u003eStd Temp Liquid: -40°F (-40°C) to 662°F (350°C)\u003c\/li\u003e\n\u003cli\u003eHigh Temp Liquid: -40°F (-40°C) to 626°F (330°C)[Add $450]\u003c\/li\u003e\n\u003cli\u003eAmbient: -40°F (-40°C) to 131°F (55°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Requirement: 24 VDC, 15 Watts maximum;\u003c\/li\u003e\n\u003cli\u003e3.6 VDC Lithium C Size battery for intrinsic safety mode. Has LCD Display but no 4-20 or ModBus\u003c\/li\u003e\n\u003cli\u003eOutput signals: Modbus RTU, 4–20 mA, and 0-1.0 KHz for flow rate indication\u003c\/li\u003e\n\u003cli\u003eDigital communications: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eMax Pressure: 1.6 MPa, 230 PSIG. (Custom up to 4.0 MPa 580 PSIG)\u003c\/li\u003e\n\u003cli\u003eDisplay: Flow rate, Total flow, Temperature, and Pressure\u003c\/li\u003e\n\u003cli\u003eWiring connection to enclosure size: M20 x 1.5\u003c\/li\u003e\n\u003cli\u003eFactory Final QC Test Certificate\u003c\/li\u003e\n\u003cli\u003eIntegral Electronics\u003c\/li\u003e\n\u003cli\u003eElectronics Enclosure: NEMA 4X \/ IP67\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch5 style=\"text-align: left;\"\u003e\u003cstrong\u003eInstructions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM_VT-222_Vortex_Flowmeter_Quick_Manual_Rev_10k.pdf?v=1770157408\" title=\"Vortex Manual for TacticalFlowMeter Series VT-222 Multivariable Vortex Flow Meters\"\u003e\u003cstrong\u003eTFM Vortex Series VT-222 Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM201_Series-Vortex_flowmeter_manual-R8.pdf?27\" title=\"Vortex Mass Flow Meter Instruction Manual\" target=\"_blank\"\u003e\u003cstrong\u003eTFM Vortex Series VT-201 Manual\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eFlow Range\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eThe Vortex meter has different minimum and maximum flow velocities it can measure based on the fluid type and meter size. Please note the values below for proper sizing of your meter.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eSteam:\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e1\/2” ANSI Flange: 4-70m\/s or \u003cstrong\u003e787-13,800 f\/m\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor 13-230 f\/s\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e1” ANSI Flange: 3-70m\/s or \u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003e590-\u003c\/strong\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cstrong\u003e13,800 f\/m \u003c\/strong\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor 9.8-230 f\/s\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e2” to 12” ANSI Flange: 1.5-\u003cwbr\u003e70m\/s \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor \u003c\/span\u003e\u003cstrong\u003e30.2-13,800 f\/m \u003c\/strong\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor 4.92-230 f\/s\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eGas:\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e1\/2” ANSI Flange: 4-65m\/s \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor \u003cstrong\u003e787-12,790 f\/m\u003c\/strong\u003e\u003c\/span\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor 13-\u003c\/span\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e213 f\/s\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e1” ANSI Flange: 3-65m\/s \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor \u003cstrong\u003e590-12, 790 f\/m \u003c\/strong\u003e\u003c\/span\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor 9.8-\u003c\/span\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003e213 f\/s\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e2” to 12” ANSI Flange: 1.5-65m\/s or \u003cstrong\u003e300- 12,790 f\/m\u003c\/strong\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor \u003c\/span\u003e\u003cspan\u003e4.9\u003c\/span\u003e\u003cspan\u003e-213\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003ef\/s\u003c\/span\u003e\n\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eLiquid:\u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e1\/2” to 12” ANSI Flange: 0.2-10m\/s \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor \u003cstrong\u003e40- 1,968 f\/m \u003c\/strong\u003e\u003c\/span\u003e \u003cmeta charset=\"utf-8\"\u003e \u003cspan\u003eor .66-32.8 f\/s\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch3\u003eNominal Vortex Flow Rates for Air\u003c\/h3\u003e\n\u003cp\u003eThe table below gives the minimum, nominal, and maximum velocities for the Vortex Meter for gases to assist users familiar with Thermal Mass Flow Meter sizing guides relative to air, with a density of 0.075 lb\/ft^3 for reference. As the pressure goes up the flows go up as well. For example, if the pressure is DOUBLED, so too does the mass flow. \u003cstrong\u003eDownload chart below \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/VortexFlowRates_2048x2048.png?v=1582566416\" title=\"Multivariable Vortex Mass Flow Meter Flow Rate table\" target=\"_blank\"\u003ehere\u003c\/a\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/VortexFlowRates_2048x2048.png?v=1582566416\" title=\"Vortex Flow Meter Flow Rate Chart\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/VortexFlowRates_2048x2048.png?v=1582566416\" alt=\"Vortex Flow Rate Chart Tactical Flow Meter\" style=\"float: none;\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003ch2 style=\"text-align: center;\"\u003e\u003cspan style=\"color: #0000ff;\"\u003e IMPORTANT Note to Thermal Mass Flow Meter users...\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eDid you know that Multivariable Vortex Flow Meters offer a significant advantage over Thermal Mass Flow Meters when it is not necessary to measure ultra low or ultra high flows? \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eDid you know that a Multivariable Vortex Meter is not affected by\u003c\/b\u003e \u003cb\u003egas composition? This means you can change gas composition and STILL report the proper Mass Flow! Why utilize a Gas Chromatograph to determine gas composition to correct your Thermal Mass Flow Meter measurement? If you need ultra low flows it makes sense but if your minimum flows are within the measuring range of a Vortex meter then consider a Multivariable Vortex Mass Flow Meter.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAs well, it is important to note that Thermal Mass Flow Meters are quite sensitive to moisture in the flow stream. The most common undesirable effect is momentary flow spikes that can upset your control system. Vortex Meters, on the other hand are NOT sensitive to moisture in the flow stream and offer a significant advantage over Thermal Mass Flow Meters if such spikes are determined to be undesirable.\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHave you ever have problems with temperature swings causing your Thermal Mass Flow meter to over or under report the flow measurement? The Multivariable Vortex Mass Flow Meter does not exhibit these symptoms simply because the vortex shedding velocity is not a function of temperature or pressure. And, with the Multivariable Vortex Meters built in Pressure and Temperature sensors you can get true Mass Flow, Pressure, AND Temperature and even gather Volume flow on those rare occasions when deemed necessary. And, you have a true pressure measurement as well as the Mass Flow and temperature. All at a price very competitive with Thermal Mass Flow Meters.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHOWEVER, if you DO need very low or very high flows we suggest the use of Thermal Mass Flow Meters. As well, Thermal Mass Flow Meters are ideal as \"Insertion Meters\" as they are small and if, and ONLY if, there is no moisture, or gas composition changes then the Thermal Mass Flow Meter is a very good choice. Otherwise, the Vortex is the best choice as it has NO sensitivity to the gas composition or droplets or hydrocarbon particulate. \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRefer to the chart above for the minimum and maximum flows for the Vortex Mass Flow Meter. Refer to the minimum and maximum velocities for the fluid you wish to use to see if a vortex meter is a good choice. If your flow is within the velocity range of the Vortex meter AND you have moisture or any change in gas composition then a Vortex meter is a better choice over the Thermal Mass Flow Meter.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Note: Vortex Flow Meters want to be rigidly mounted or isolated from vibration to prevent the vibrating energy to be transmitted to the Vortex Piezo Sensors. This can be accomplished by rigid mounts to a solid base or good vibration isolation.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow to use button interface and ModBus RTU video:\u003c\/strong\u003e\u003cstrong\u003eTo get the most out of the video open the link below and print out the document or open it in another window.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/h5\u003e\n\u003c!-- split --\u003e\n\u003ctable style=\"width: 400.667px;\" height=\"400.667px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 119.667px;\"\u003e \u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TacticalFlowMeter-Vortex-Display-300px.png?v=1727718820\" loading=\"lazy\"\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cp\u003eSee the video below to see how to use the buttons on the display within the enclosure.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eFeatures LARGE LCD display, shows the Flow Rate, Total Flow, Temperature, and Pressure in user selectable units.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eMenu\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch2\u003eVortex VT-210 Meter Menu Details\u003c\/h2\u003e\n\u003cp\u003eMENU 22\u003cbr\u003eQ Unit \u0026gt;\u0026gt; l\/m\u003cbr\u003eQ Mode \u0026gt;\u0026gt; Qvw actual (We are measuring volume flow....)\u003cbr\u003eQ Factor \u0026gt;\u0026gt; 2121.47 Do Not Change (This is stamped on the side of the meter)\u003cbr\u003eDensity \u0026gt;\u0026gt; 875 kg\/m3 (Water is 1000)\u003cbr\u003eQ20mA \u0026gt;\u0026gt; 250 (FULL SCALE... If your meter is 250 l\/m)\u003cbr\u003eQ Cut-Zero % \u0026gt;\u0026gt; 5\u003cbr\u003eQ Up Al \u0026gt;\u0026gt; 250 to turn the alarm on at 100%\u003cbr\u003eQ Dn Al \u0026gt;\u0026gt; 25 to turn the alarm at 10% flow\u003cbr\u003eDamp S \u0026gt;\u0026gt; 6\u003cbr\u003eComm Address \u0026gt;\u0026gt; 0\u003cbr\u003eClear Q \u0026gt;\u0026gt; Clears Totalizer, Password = 70\u003cbr\u003e\u003cbr\u003eMENU 33\u003cbr\u003eLanguage \u0026gt;\u0026gt; English\u003cbr\u003ePulse Type \u0026gt;\u0026gt; F_adj\u003cbr\u003ePulse Factor \u0026gt;\u0026gt; 0.01\u003cbr\u003eComm Param \u0026gt;\u0026gt; 9600, No\u003cbr\u003eComm Switch \u0026gt;\u0026gt; ON\u003cbr\u003eP_display \u0026gt;\u0026gt; MEASURE\u003cbr\u003eSet Pc \u0026gt;\u0026gt; 0\u003cbr\u003eP0-Ref \u0026gt;\u0026gt; 101.3KPa\u003cbr\u003eT_display \u0026gt;\u0026gt; MEASURE\u003cbr\u003eSet Tc \u0026gt;\u0026gt; 20 Deg C\u003cbr\u003eT-TYPE \u0026gt;\u0026gt; Pt=100\u003cbr\u003eTn \u0026gt;\u0026gt; 20 Deg C\u003cbr\u003eEnviron-T \u0026gt;\u0026gt; -20 Deg C (-10 C is fine if you do not get them cold.)\u003cbr\u003eQ-adj \u0026gt;\u0026gt; DO NOT change this setting\u003cbr\u003e\u003cbr\u003e\u003cmeta charset=\"utf-8\"\u003eMENU 44\u003cbr\u003eSignal-TYPE \u0026gt;\u0026gt; LF: DN40-500 Lqd\u003cbr\u003eGain \u0026gt;\u0026gt; G=9\u003cbr\u003eVPP limit \u0026gt;\u0026gt; 100mV\u003cbr\u003eFre-Range \u0026gt;\u0026gt; 11=34-850Hz\u003cbr\u003eWork Type \u0026gt;\u0026gt; Digital\u003cbr\u003ean-noise TYPE \u0026gt;\u0026gt; ANS\u003cbr\u003eSignal-Adj-Set \u0026gt;\u0026gt; FIlter 10 or OFF\u003cbr\u003e50Hz Cut \u0026gt;\u0026gt; ON\u003cbr\u003eK-LINE ADJ \u0026gt;\u0026gt; DO NOT change this setting\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cimg alt=\"Multivariable Vortex Meter Dimensions, TacticalFlowMeter.com\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Multivariable_Vortex_Meter_Dimensions._jpg_grande.jpg?v=1555698757\" style=\"float: none;\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eHow to Invoke Variable K-Factors in the Tactical Flow Meter Vortex Flow Meter:\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eScreen 33 Instructions are for advanced users only. Do NOT invoke this screen on your meter unless you have a pressing need. It is important to note all settings PRIOR to making any changes. Note: Left button HOLD gets you OUT of menus.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSee example spreadsheet \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Vortex_Coefficient_Calibration_1.xlsx?217\" title=\"Example Vortex Calibration Spreadsheet\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Example-FrequencyCalcRev1.xls?215\" title=\"Example VOrtex Calibration Spreadsheet\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Vortex_Coefficient_Calibration_1.xlsx?217\" title=\"Example Vortex Calibration Spreadsheet\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Vortex_Flow_Meter_Calibration_Coefficients_7c6b739e-ca44-45e0-b601-4dd05de6ca44_480x480.png?v=1575080535\" alt=\"\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Example-FrequencyCalcRev1.xls?215\" title=\"Example VOrtex Calibration Spreadsheet\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eBefore exiting ensure you SAVE the data and CONFIRM the % numbers are ever increasing in from element 0 to element 4. The Correction ratio must be between 0.8 and 1.2. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #000000; font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 1.4em;\"\u003e\u003cspan style=\"background-color: #ffff00;\"\u003eWhere to get Power Supplies, Gaskets, Nuts and Bolts\u003c\/span\u003e \u003ca title=\"Where to get 24 VDC Power Supplies and flange bolts and gaskets\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Power_Supplies_Bolts_Gaskets_and_more.pdf?v=1605288973\" target=\"_blank\"\u003eLink\u003c\/a\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Note: Vortex Flow Meters want to be rigidly mounted or isolated from vibration to prevent the vibrating energy to be transmitted to the Vortex Piezo Sensors. This can be accomplished by rigid mounts to a solid base or good vibration isolation. We show some settings below as examples for your study. The video above shows how to enter the configuration modes.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong style=\"color: #000000; font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 1.4em;\"\u003e\u003c\/strong\u003e\u003cstrong\u003eTypical Vortex Meter Settings for reading Volume Flow for Liquids with a Full Scale of 250 l\/m for a fluid with a density of 875 kg\/m3 for a 3\" Vortex Meter where the vortex frequency is from 34-850 Hz.\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003e3D Files\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eLink to Copyrighted Wafer Meter STEP Files \u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca rel=\"noopener\" title='Copyrighted STEP Files for TFM 3,4,6 \u0026amp; 10\" Wafer Meters' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFMCopyrightedWaferMeterStep-3-4-6-10-Inch.zip?v=1726764821\" style=\"color: rgb(43, 0, 255);\" target=\"_blank\"\u003ehere\u003c\/a\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003e  3',4\",6\" \u0026amp; 10\" SIZE ANSI 150# Wafer\u003c\/span\u003e\u003cbr\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLink to Copyrighted FLANGED Meter STEP Files \u003cspan style=\"color: rgb(43, 0, 255);\"\u003ehere \u003cspan style=\"color: rgb(0, 0, 0);\"\u003efrom 0.5 to 2.5\" ANSI 150# Flange \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003eLink to Copyrighted FLANGED Meter STEP Files \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/CopyrightedVortex_3-4-5-6-8-10-12Inch_ANSI150.zip?v=1726794333\" style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" target=\"_blank\"\u003e\u003cstrong\u003ehere\u003c\/strong\u003e\u003c\/a\u003e\u003c\/span\u003e  \u003cstrong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"color: rgb(0, 0, 0);\"\u003efrom 3 to 12\" ANSI 150# Flange \u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eCut Sheets\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff;\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFMV_vortex_data_sheet_Rev_4.pdf?v=1595288115\" title=\"Vortex Meter Cut Sheet Tactical Flow Meter\" target=\"_blank\"\u003eCut Sheet\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eVideos\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eVideo showing User Interface for TacticalFlowMeter.com VT-222 Series Multivariable Vortex Mass Flow Meter:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"ygTNTIO6eyU\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/ygTNTIO6eyU\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eHow to use ModBus Poll to read the totalizer in a Type 2 Vortex Meter.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"93Sufdg7DMU\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/93Sufdg7DMU\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eVideo showing how to use the spreadsheet above and the Front Panel Interface with Menu 33:\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"sZOLHFcqHLM\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/sZOLHFcqHLM\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2\u003eHow to verify and set up Full Scale and Units:\u003c\/h2\u003e\n\u003cp\u003eRefer to the Vortex Meter LCD Interface Video above for overview and introduction to using buttons. \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"gqSA2lck0-E\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/gqSA2lck0-E\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Tactical Flow Meter","offers":[{"title":"1\/2\" \/ ANSI","offer_id":42082404761769,"sku":"Vortex_AN_1_2","price":2600.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ TriClover","offer_id":42082404794537,"sku":"Vortex_TC_1_2","price":2700.0,"currency_code":"USD","in_stock":true},{"title":"3\/4\" \/ ANSI","offer_id":42082404827305,"sku":"Vortex_AN_3_4","price":2800.0,"currency_code":"USD","in_stock":true},{"title":"3\/4\" \/ TriClover","offer_id":42082404860073,"sku":"Vortex_TC_3_4","price":2900.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ ANSI","offer_id":42082404892841,"sku":"Vortex_AN_1","price":2900.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ TriClover","offer_id":42082404925609,"sku":"Vortex_TC_1","price":3000.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ ANSI","offer_id":42082404958377,"sku":"Vortex_AN_1_1_2","price":3300.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ TriClover","offer_id":42082404991145,"sku":"Vortex_TC_1_1_2","price":3400.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ ANSI","offer_id":42082405023913,"sku":"Vortex_AN_2","price":3400.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ TriClover","offer_id":42082405056681,"sku":"Vortex_TC_2","price":3500.0,"currency_code":"USD","in_stock":true},{"title":"2 1\/2\" \/ ANSI","offer_id":42082405089449,"sku":"Vortex_AN_2_1_2","price":3800.0,"currency_code":"USD","in_stock":true},{"title":"2 1\/2\" \/ TriClover","offer_id":42082405122217,"sku":"Vortex_TC_2_1_2","price":3900.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ ANSI","offer_id":42082405154985,"sku":"Vortex_AN_3","price":4300.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ TriClover","offer_id":42082405187753,"sku":"Vortex_TC_3","price":4400.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ ANSI","offer_id":42082405220521,"sku":"Vortex_AN_4","price":5000.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ TriClover","offer_id":42082405253289,"sku":"Vortex_TC_4","price":5100.0,"currency_code":"USD","in_stock":true},{"title":"6\" \/ ANSI","offer_id":42082405286057,"sku":"Vortex_AN_6","price":5800.0,"currency_code":"USD","in_stock":true},{"title":"8\" \/ ANSI","offer_id":42082405351593,"sku":"Vortex_AN_8","price":6800.0,"currency_code":"USD","in_stock":true},{"title":"8\" to 72\" Insertion \/ ANSI","offer_id":46413480132777,"sku":null,"price":6188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM_Vortex_ANSI_Front.webp?v=1758820692"},{"product_id":"turbine-flow-meter","title":"Turbine Flow Meter \u003cbr\u003efor Liquid Flow \u003cbr\u003e1\/2\" to 8\"","description":"\u003cp\u003eA turbine flow meter is used for volumetric total flow \u0026amp;\/or flow rate measurement \u0026amp; has a relatively simple working principle. As fluid flows through the turbine meter, it impinges upon turbine blades that are free to rotate about an axis along the center line of the turbine housing. The angular (rotational) velocity of the turbine rotor is directly proportional to the fluid velocity flowing through the turbine. The resulting output is taken by an electrical pickoff(s) mounted on the flow meter body.\u003c\/p\u003e\n\u003cp\u003eA turbine flow meter for liquids diesel, \u0026amp; oil ship from stock \u0026amp; configured for you OEM OK\u003c\/p\u003e\n\u003cp\u003eEASY to use Turbine Flow Meters. Check our stock and prices that beats our competition.\u003c\/p\u003e\n\u003c!--split--\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003eTurbine Flow Meter Specifications\u003c\/h3\u003e\n\u003cdiv class=\"product-bullet-list\"\u003e\n\u003cul\u003e\n\u003cli\u003eWetted Materials all 304 SS\u003c\/li\u003e\n\u003cli\u003eVelocity Range: See detail below.\u003c\/li\u003e\n\u003cli\u003eVelocity Accuracy: +\/- 0.5% of reading\u003c\/li\u003e\n\u003cli\u003eRepeatability of +\/- 0.05% of reading\u003c\/li\u003e\n\u003cli\u003e1\/2\" to 8\" 150# ANSI Flange Connections, up to 12\" available custom.\u003c\/li\u003e\n\u003cli\u003eLCD Display\u003c\/li\u003e\n\u003cli\u003eTemperature Accuracy +\/- 1 Deg C\u003c\/li\u003e\n\u003cli\u003eTemperature:\u003c\/li\u003e\n\u003cli\u003e\n\u003cul\u003e\n\u003cli\u003eLiquid Only: -40°F (-40°C) to 482°F (250°C)\u003c\/li\u003e\n\u003cli\u003eAmbient: -40°F (-40°C) to 131°F (55°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Requirement: 24 VDC, 15 Watts maximum;\u003c\/li\u003e\n\u003cli\u003e3.6 VDC Lithium C or D Size battery. Has LCD Display but no outputs for 4-20, pulse, or ModBus to allow long run time\u003c\/li\u003e\n\u003cli\u003eOutput signals: Modbus RTU, 4–20 mA, and 0-1.0 KHz for flow rate indication\u003c\/li\u003e\n\u003cli\u003eDigital communications: Modbus RTU\u003c\/li\u003e\n\u003cli\u003eMax Pressure 1.6 MPa, 230 PSIG. (Custom up to 4.0 MPa 580 PSIG)\u003c\/li\u003e\n\u003cli\u003eDisplay: Flow rate and Total flow\u003c\/li\u003e\n\u003cli\u003eWiring connection to enclosure size: M20 x 1.5\u003c\/li\u003e\n\u003cli\u003eFactory Final QC Test Certificate\u003c\/li\u003e\n\u003cli\u003eIntegral Electronics\u003c\/li\u003e\n\u003cli\u003eElectronics Enclosure NEMA 4X \/ IP67\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eInstructions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003e\u003ca title=\"Turbine Flow Meter Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Quick_Turbine_Flow_Meter_Manual_Rev_3.pdf?160\" target=\"_blank\"\u003eTFM Turbine Flow Meter Manual\u003c\/a\u003e\u003c\/h3\u003e\n\u003ch3\u003eWhere to get Power Supplies, Gaskets, Nuts, and Bolts \u003ca style=\"color: #2b00ff; text-decoration: underline;\" title=\"Where to get 24 VDC Power Supplies and flange bolts and gaskets\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Power_Supplies_Bolts_Gaskets_and_more.pdf?v=1605288973\" target=\"_blank\"\u003eLink\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003ch5\u003e\u003cstrong\u003eFlow Range\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003eTurbine Flow Meter Ranges:\u003c\/h3\u003e\n\u003cp\u003eThe turbine meter has different minimum and maximum flow rated it can measure based on the meter size. Please note the values below for proper sizing of your meter. These flows are relative to water.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLiquids:\u003cbr\u003e\u003c\/strong\u003e \u003cimg loading=\"lazy\" alt=\"Liquid Turbine Flow Meter Flow Rates\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Liquid-Turbine-Flow-Meter-Flow-Ranges_large.png?v=1562103230\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003eTurbine Flow Meter Digital Display\u003c\/h3\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" height=\"154\" width=\"154\" alt=\"Turbine flow meter display, tactical Flow Meter\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/DisplayTurbine_large.png?v=1561087656\"\u003e\u003c\/p\u003e\n\u003cp\u003eBest price on high-end liquid Turbine Flow Meters and Sanitary fitting Turbine flow meters with ModBus RTU, 4-20 mA out, and frequency output.\u003c\/p\u003e\n\u003cp\u003eFeatures LARGE LCD display shows the Flow Rate and Total Flow in user selectable units.\u003c\/p\u003e\n\u003cdiv id=\"tab-3\" class=\"tab\"\u003e\u003c\/div\u003e\n\u003cdiv class=\"tab\"\u003e\n\u003ch5\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003eTurbine Flange Meter Dimensions with 150# ANSI B 16.5 Flanges\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Turbine_Flow_Meter_Dimensions_TacticalFlowMeter.com.png?v=1774966583\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003ca title=\"Turbine Flow Meter Manual and Specifications\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Quick_Turbine_Flow_Meter_Manual_Rev_3.pdf?160\" target=\"_blank\"\u003e\u003cstrong\u003eDownload Brochure\u003c\/strong\u003e\u003c\/a\u003e\u003cstrong\u003e , Specifications, and Dimensions:\u003c\/strong\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003ca title=\"ModBus RTU Commands and Meter codes for VOrtex Flow Meter\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM201_Series-Vortex_flowmeter_manual-R8.pdf?27\" target=\"_blank\"\u003e\u003cstrong\u003e\u003cimg loading=\"lazy\" alt=\"Turbine Flow ModBus Register List\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Turbine_Flow_Meter_ModBus_Register_List_1024x1024.jpg?v=1561088586\"\u003e\u003cbr\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow to use the 2 button interface video: To get the most out of the video open the link below and print out the document or open it in another window. Note the calibration coefficient Q Factor, K [P\/m3] will show up on the meter as 218364 for a calibration coefficient of 218.364 on the calibration certificate. \u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eVideos\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003e\u003cstrong\u003eHow to configure the Turbine Flow Meter. \u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv data-id=\"Ov0m5oafC6I\" class=\"youtube-lite\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg loading=\"lazy\" alt=\"Video Thumbnail\" src=\"https:\/\/img.youtube.com\/vi\/Ov0m5oafC6I\/hqdefault.jpg\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv data-id=\"7IpmAMy4Zyo\" class=\"youtube-lite\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg loading=\"lazy\" alt=\"Video Thumbnail\" src=\"https:\/\/img.youtube.com\/vi\/7IpmAMy4Zyo\/hqdefault.jpg\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Tactical Flow Meter","offers":[{"title":"1\/2\" \/ ANSI 150#","offer_id":42082434744489,"sku":"Turbine-AN-1_2","price":925.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ TriClover","offer_id":42082434777257,"sku":"Turbine-TC-1_2","price":1025.0,"currency_code":"USD","in_stock":true},{"title":"3\/4\" \/ ANSI 150#","offer_id":42082434810025,"sku":"Turbine-AN-3_4","price":950.0,"currency_code":"USD","in_stock":true},{"title":"3\/4\" \/ TriClover","offer_id":42082434842793,"sku":"Turbine-TC-3_4","price":1050.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ ANSI 150#","offer_id":42082434875561,"sku":"Turbine-AN-1","price":1000.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ TriClover","offer_id":42082434908329,"sku":"Turbine-TC-1","price":1100.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ ANSI 150#","offer_id":42082434941097,"sku":"Turbine-AN-1_1_2","price":1085.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ TriClover","offer_id":42082434973865,"sku":"Turbine-TC-1_1_2","price":1185.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ ANSI 150#","offer_id":42082435006633,"sku":"Turbine-AN-2","price":1135.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ TriClover","offer_id":42082435039401,"sku":"Turbine-TC-2","price":1235.0,"currency_code":"USD","in_stock":true},{"title":"2 1\/2\" \/ ANSI 150#","offer_id":42082435072169,"sku":"Turbine-AN-2_1_2","price":1225.0,"currency_code":"USD","in_stock":true},{"title":"2 1\/2\" \/ TriClover","offer_id":42082435104937,"sku":"Turbine-TC-2_1_2","price":1325.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ ANSI 150#","offer_id":42082435137705,"sku":"Turbine-AN-3","price":1475.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ TriClover","offer_id":42082435170473,"sku":"Turbine-TC-3","price":1575.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ ANSI 150#","offer_id":42082435203241,"sku":"Turbine-AN-4","price":1560.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ TriClover","offer_id":42082435236009,"sku":"Turbine-TC-4","price":1660.0,"currency_code":"USD","in_stock":true},{"title":"6\" \/ ANSI 150#","offer_id":42082435268777,"sku":"Turbine-AN-6","price":2750.0,"currency_code":"USD","in_stock":true},{"title":"8\" \/ ANSI 150#","offer_id":42082435334313,"sku":"Turbine-AN-8","price":3750.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/Turbine_meter_1.jpg?v=1629503033"},{"product_id":"1-2-to-8-coriolis-mass-flow-meter","title":"Coriolis Mass Flow Meter \u003cbr\u003efor Liquid Flow and Gas Flow \u003cbr\u003e3\/8\" to 10\" UL APPROVED 0.1% Accuracy","description":"\u003cdiv style=\"text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/UL_Logo_50x50.png?v=1774995531\" alt=\"UL Approved Coriolis Flow Meter\" style=\"margin-bottom: 16px; float: none;\"\u003eUL Approved \u003cmeta charset=\"utf-8\"\u003e \u003cb id=\"docs-internal-guid-fc0cdb0f-7fff-455b-5802-cc00be5e1d76\"\u003e\u003cspan\u003eClass I, Division 1, Group B, C and D 0.1% Accuracy \u003c\/span\u003e\u003c\/b\u003eCoriolis flow meters (also referred to as Coriolis mass flow controllers) are very accurate flow meters designed to measure the flow rate of liquids, slurries, \u0026amp; oils. Coriolis meters even work well in difficult applications such as Asphalt and non-homogeneous food flow measurement.\u003c\/div\u003e\n\u003cp\u003eOur flow meters ship from stock (usually within 48hrs) and are configured for you to be plug and play. They feature a very easy to use user interface with \"Thru the Glass\" programming technology and do not need HART for configuration like old technology meters. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGet a quote RIGHT NOW, with NO WAIT or cumbersome need to find a rep or distributor. Our transparent pricing shows you upfront pricing. The price you see is what you get and can be lowered with quantities and blanket orders. Call 831-344-8080 to get what you need.\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA Coriolis flow meter contains a tube that is energized by a fixed vibration. When a fluid (gas or liquid) passes through this tube, the mass flow momentum will cause a change in the tube vibration; the tube will twist, resulting in a phase shift. This phase shift can be measured \u0026amp; a linear output derived proportional to flow.\u003c\/p\u003e\n\u003cp\u003eOur EASY to use UL Approved \u003cmeta charset=\"utf-8\"\u003e\u003cb id=\"docs-internal-guid-5a7e23c6-7fff-8f63-7ce2-eabfc02ffbc5\"\u003e\u003cspan\u003eClass I, Division 1, Group B, C and D \u003c\/span\u003e\u003c\/b\u003eCORIOLIS Mass Flow Meters are in stock at\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eprices that beat our competition\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c!--split--\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch6 style=\"font-size: 1.17em; font-weight: bold; margin: 1em 0;\"\u003eCoriolis Mass Flow Meter Specifications\u003c\/h6\u003e\n\u003cdiv class=\"product-bullet-list\" style=\"text-align: start;\"\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003e\n\u003cmeta charset=\"utf-8\"\u003e \u003cb id=\"docs-internal-guid-fc0cdb0f-7fff-455b-5802-cc00be5e1d76\"\u003e\u003cspan\u003eClass I, Division 1, Group B, C and D\u003c\/span\u003e\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003eSensor Wetted Materials: 316 SS Standard\u003c\/li\u003e\n\u003cli\u003eFlanges and Flow Splitter Materials: 304 SS Standard\u003c\/li\u003e\n\u003cli\u003eFlow Rates:  0.1 kg\/h to 1,000,000 kg\/h relative to water\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/- 0.1%, 0.2% or 0.5% of reading in gas or water.\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003e0.1% not always in stock.\u003c\/li\u003e\n\u003cli\u003eNote: turndown typically 20:1\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eRepeatability: +\/- 0.02% of reading\u003c\/li\u003e\n\u003cli\u003ePipe Size:\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003e3\/8\" to 8\" 150# ANSI Flange Connections\u003c\/li\u003e\n\u003cli\u003eUp to 12\" available custom \u003c\/li\u003e\n\u003cli\u003e1\/4\" Swage to 3\/4\" Swage and TriClover Sanitary fittings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eOLED Display\u003c\/li\u003e\n\u003cli\u003eTemperature Accuracy: +\/- 1 Deg C\u003c\/li\u003e\n\u003cli\u003eTemperature:\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eGas: -58°F (-50°C) to 257°F (125°C)\u003c\/li\u003e\n\u003cli\u003eAmbient: -40°F (-40°C) to 131°F (55°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003ePower Requirement: 24 VDC or 85-220 VAC, 15 Watts maximum;\u003c\/li\u003e\n\u003cli\u003eOutput signals: Modbus RTU, 4–20 mA, and 0-10 KHz for flow rate indication\u003c\/li\u003e\n\u003cli\u003eDigital communications: Modbus RTU Standard, HART Optional\u003c\/li\u003e\n\u003cli\u003eProof Pressure: 4.0 MPa, 580 PSIG,\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eUp to 25 MPa (3,600 PSIG) available.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eDisplay: Flow rate, Total flow, Temperature, and Density\u003c\/li\u003e\n\u003cli\u003eWiring connection to enclosure size: M20 x 1.5 or NPT Optionally available.\u003c\/li\u003e\n\u003cli\u003eIntegral Electronics installation\u003c\/li\u003e\n\u003cli\u003eExplosion-Proof Rating: UL\/CSA Class 1 Div 1 standard.\u003c\/li\u003e\n\u003cli\u003eElectronics Enclosure: NEMA 4X \/ IP67\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eInstructions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003ca title=\"Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM_1001_Coriolis_Flow_Meter_Manual_Rev_15k.pdf?v=1661203555\"\u003eTFM Coriolis Flow Meter User Manual\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eFlow Range\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"text-decoration: underline;\"\u003eTypes M and S\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Coriolis_Mass_Flow_Meter_Flow_Rates.webp\" alt=\"Coriolis Mass Flow Meter Flow Rates\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eTypes T and U\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Flow_Rates_Typs_T_and_U_Coriolis_Mass_Flow_Meter.webp\" alt=\"Flow Rate Chart Type T and U Coriolis Mass Flow Meter\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Coriolis_Flow_Meter_Rates_in_GPM.webp\" alt=\"Coriolis Mass Flow Meter Flow Rate in GPM\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/M_Series_Coriolis_Flow_Meter_Dimensions.webp\" alt=\"M Series Coriolis Mass Flow Meter Dimensions\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eNote: Click image to open a PDF.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Coriolis_Mass_Flow_Meter_Model_Number_for_Custom_Meters.pdf?v=1606973612\"\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Coriolis_Mass_Flow_Meter_Model_Number_for_Custom_Meters.webp\" alt=\"Tactical Flow Meter Coriolis Mass Flow Meter Part Number Matrix\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cimg class=\"responsive-content-image\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/DisplayForWeb.webp\" alt=\"Coriolis Mass Flow Meter Display\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003eFeatures LARGE OLED display, shows the Instantaneous (Instant) Flow Rate, Total Flow, Temperature, and Density in user selectable units.\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eMounting Guide\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cimg class=\"responsive-content-image\" alt=\"Coriolis Mass Flow Meter Flow Direction\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Coriolis_Mass_Flow_Meter_Flow_Direction.webp\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eProgramming Menu\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eNote: Click image to open a PDF.\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"Coriolis Mass Flow Meter User Interface Menu\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TMFM-Coriolis_Menu_Chart-2020.pdf?v=1598547304\" target=\"_blank\"\u003e\u003cimg class=\"responsive-content-image\" alt=\"Coriolis User Interface Menu\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TMFM_Coriolis_Menu.webp\" loading=\"lazy\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eZero \u0026amp; FS Calibration\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eNOTE: It is critical to invoke the zero point calibration after installation.\u003c\/p\u003e\n\u003cp\u003eEvery Coriolis Meter must be zeroed in the final installation point with the fluid that will be measured. Make sure the meter has warmed up for at least 15 minutes before invoking the zero function. Make sure the measuring tube is fully filled with liquid. Turn off the stop valves, make sure the liquid is in a stationary state, and invoke calibrate the zero point as shown below. The zero function is in process when the display indicates \"Zeroing, please wait for 30 s\" for about 30 seconds and then reverts to the zero uS display mode. This function is CRITICAL to allow the meter to determine the resonant frequency of the measuring tube is to determine the density of the fluid within it. This step cannot be skipped. Once this step is complete you will want to confirm the measured density is accurate. Coriolis mass flow meters directly measure the mass flow and the density of the fluid. The volume flow rate is calculated by mass flow divided by density. If the density measured at the zero point is not accurate, then the flow rates will be affected as well. We explain what is shown in the manual below for ease of access.\u003c\/p\u003e\n\u003cp\u003e\u003cimg class=\"responsive-content-image\" alt=\"Zero Coriolis Mass Flow Meter\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Zero_Coriolis_Mass_Flow_Meter.webp\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUsing the root menu (see Figure 2.14) press \u003cb\u003e↓\u003c\/b\u003e button several times to move to the Menu item “Configuration Press E to enter”. Press E button and enter the password \u003cb\u003e(default password is 000000)\u003c\/b\u003e. To enter the password press \u003cb\u003e↓\u003c\/b\u003e to increment the currently selected digit, to move to the next digit press → button. After correct password entry The screen will say Flow Config Press E to enter. Press E. Next the screen will say Zero Calibration with the zero uS below. Press E to start. The Zeroing message will appear with a blinking N. Use the → to make the Y blink.  Press E to start zero calibration procedure. A message “Zeroing?” will appear. Press E to confirm that. Zero calibration procedure lasts for 30 seconds, the count down time is displayed.\u003c\/li\u003e\n\u003cli\u003eNOTE: Multiple hits of the Center Button gets you OUT of the menu structure. \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHow to ZERO a Coriolis Mass Flow Meter\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eVideo showing Zero Calibration \u003ca href=\"https:\/\/youtube.com\/shorts\/Q0p2qDuJPpg?feature=share\" title=\"Video: How to Zero a Coriolis Mass Flow Meter\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;\"\u003ehere\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHow to Set the FULL SCALE on a Coriolis Mass Flow Meter\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eVideo showing how to change the Full Scale for a Coriolis Mass Flow Meter \u003ca href=\"https:\/\/youtube.com\/shorts\/Ts9P4jSsM_c?feature=share\" title=\"How to change the 4-20 mA Full Scale for a Coriolis Mass Flow Meter. Changing Coriolis Mass Flow Meter Full Scale\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cspan style=\"text-decoration-thickness: initial; text-decoration-style: initial; text-decoration-color: initial;\"\u003ehere\u003c\/span\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eUL Approval Certificate\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003e\u003ca style=\"color: rgb(43, 0, 255);\" rel=\"noopener\" title=\"UL Approval Certificate Class I, Division 1, Group B, C and D  Product TFM-C\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/E360841-Vol2-20260318_UL_Certificate_Coriolis_TFM-C.pdf?v=1774993026\" target=\"_blank\"\u003eUL Approval Certificate\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003e\u0026lt;-Click to download\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"UL Certificate Coriolis Mass Flow Meter Class I, Division 1, Group B, C and D\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/UL_Certificate_COriolis_TFM-C_480x480.png?v=1774993344\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003ePage 2:\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg style=\"margin-bottom: 16px; float: none;\" alt=\"UL Certificate Coriolis Mass Flow Meter Class I, Division 1, Group B, C and D\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/UL_Certificate_COriolis_TFM-C-Pg2_480x480.png?v=1774993401\"\u003e\u003c\/div\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cmeta charset=\"utf-8\"\u003e \u003cb id=\"docs-internal-guid-09713f6d-7fff-9139-8c96-fdd3bb4028e8\"\u003e\u003cspan\u003eCERTIFICATE OF COMPLIANCE \u003c\/span\u003e\u003c\/b\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThis is to certify that representative samples of the product as specified on this certificate were tested according to the current UL requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"252\"\u003e \u003ccol width=\"24\"\u003e \u003ccol width=\"426\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eCertificate number(s):\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eE534391\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eReport reference:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eE534391-20230508\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eIssue Date:\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003e2026-MARCH-18\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cdiv dir=\"ltr\" align=\"left\"\u003e\n\u003ctable style=\"width: 100%;\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"252\" style=\"width: 44.7653%;\"\u003e \u003ccol width=\"174\" style=\"width: 30.8664%;\"\u003e \u003ccol width=\"276\" style=\"width: 23.8267%;\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eProducts Covered\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eProduct Designation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eNomenclature\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eClass I, Division 1, Group B, C and D\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eTFM-C\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cbr\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eWiring\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch6 style=\"font-size: 1.17em; font-weight: bold; margin: 1em 0;\"\u003e\u003ca title=\"Coriolis Mass Flow Meter WIring Validation\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Coriolis_Mass_Flow_Meter_Connection_Validation.pdf?v=1632242793\" target=\"_blank\"\u003e\u003cstrong\u003eCoriolis Wiring Validation\u003c\/strong\u003e\u003c\/a\u003e\u003c\/h6\u003e\n\u003ch5\u003e\u003cstrong\u003eGas Eliminator\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv class=\"row align-items-center\"\u003eGAS ELIMINATOR NOTES:\n\u003cp\u003eAll flow meters require that the fluid delivered is free of gas bubbles. The TFM-9005 Gas Eliminator is one way to address this need. Frequently used in oil fields as well as other processes that have entrained gases.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM-F9005_Gas_Eliminator_and_Strainer_Cut_Sheet.pdf?220\" target=\"_blank\"\u003eTFM-F9005 Gas Eliminator and Strainer Cut Sheet\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e","brand":"Tactical Flow Meter","offers":[{"title":"3\/8\" Sensor \/ 1\/2\" 150# ANSI Flange \/ 0.5% Acc No HART","offer_id":42082383069353,"sku":"CoriU-AN-3_8_0.5","price":5900.0,"currency_code":"USD","in_stock":true},{"title":"3\/8\" Sensor \/ 1\/2\" 150# ANSI Flange \/ 0.5% Acc w\/ HART","offer_id":42082383102121,"sku":"CoriU-AN-3_8-0.5-Hart","price":6100.0,"currency_code":"USD","in_stock":true},{"title":"3\/8\" Sensor \/ 1\/2\" 150# ANSI Flange \/ 0.2% Acc No HART","offer_id":43002127188137,"sku":"CoriU-AN-3_8-0.2","price":6900.0,"currency_code":"USD","in_stock":true},{"title":"3\/8\" Sensor \/ 1\/2\" 150# ANSI Flange \/ 0.2% Acc w\/ HART","offer_id":43002127220905,"sku":"CoriU-AN-3_8-0.2-Hart","price":7100.0,"currency_code":"USD","in_stock":true},{"title":"3\/8\" Sensor \/ 1\/2\" 150# ANSI Flange \/ 0.1% Acc No HART","offer_id":43002127253673,"sku":"CoriU-AN-3_8-0.1","price":9100.0,"currency_code":"USD","in_stock":true},{"title":"3\/8\" Sensor \/ 1\/2\" 150# ANSI Flange \/ 0.1% Acc w\/ HART","offer_id":43002127286441,"sku":"CoriU-AN-3_8-0.1-Hart","price":9300.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ ANSI 150# \/ 0.5% Acc w\/ HART","offer_id":42082383200425,"sku":"CoriU-AN-1_2-0.5-Hart","price":6200.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ ANSI 150# \/ 0.5% Acc No HART","offer_id":43002293059753,"sku":"CoriU-AN-1_2-0.5","price":6000.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ ANSI 150# \/ 0.2% Acc No HART","offer_id":43002127450281,"sku":"CoriU-AN-1_2-0.2","price":7200.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ ANSI 150# \/ 0.2% Acc w\/ HART","offer_id":43002127483049,"sku":"CoriU-AN-1_2-0.2-Hart","price":7400.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ ANSI 150# \/ 0.1% Acc No HART","offer_id":43002127515817,"sku":"CoriU-AN-1_2-0.1","price":9200.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ ANSI 150# \/ 0.1% Acc w\/ HART","offer_id":43002127548585,"sku":"CoriU-AN-1_2-0.1-Hart","price":9400.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ TriClover \/ 0.5% Acc No HART","offer_id":42082383233193,"sku":"CoriU-TC-1_2-0.5","price":6000.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ TriClover \/ 0.5% Acc w\/ HART","offer_id":42082383265961,"sku":"CoriU-TC-1_2-0.5-Hart","price":6200.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ TriClover \/ 0.2% Acc No HART","offer_id":43002127581353,"sku":"CoriU-TC-1_2-0.2","price":7200.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ TriClover \/ 0.2% Acc w\/ HART","offer_id":43002127614121,"sku":"CoriU-TC-1_2-0.2-Hart","price":7400.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ TriClover \/ 0.1% Acc No HART","offer_id":43002127646889,"sku":"CoriU-TC-1_2-0.1","price":9200.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ TriClover \/ 0.1% Acc w\/ HART","offer_id":43002127679657,"sku":"CoriU-TC-1_2-0.1-Hart","price":9400.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ ANSI 150# \/ 0.5% Acc No HART","offer_id":42078323015849,"sku":"CoriU-AN-1-0.5","price":7100.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ ANSI 150# \/ 0.5% Acc w\/ HART","offer_id":42078323048617,"sku":"CoriU-AN-1-0.5-Hart","price":7300.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ ANSI 150# \/ 0.2% Acc No HART","offer_id":43002127712425,"sku":"CoriU-AN-1-0.2","price":8200.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ ANSI 150# \/ 0.2% Acc w\/ HART","offer_id":43002127745193,"sku":"CoriU-AN-1-0.2-Hart","price":8400.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ ANSI 150# \/ 0.1% Acc No HART","offer_id":43002127777961,"sku":"CoriU-AN-1-0.1","price":9700.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ ANSI 150# \/ 0.1% Acc w\/ HART","offer_id":43002127810729,"sku":"CoriU-AN-1-0.1-Hart","price":9900.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ TriClover \/ 0.5% Acc No HART","offer_id":42082383298729,"sku":"CoriU-TC-1-0.5","price":7100.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ TriClover \/ 0.5% Acc w\/ HART","offer_id":42082383331497,"sku":"CoriU-TC-1-0.5-Hart","price":7300.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ TriClover \/ 0.2% Acc No HART","offer_id":43002127843497,"sku":"CoriU-TC-1-0.2","price":8200.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ TriClover \/ 0.2% Acc w\/ HART","offer_id":43002127876265,"sku":"CoriU-TC-1-0.2-Hart","price":8400.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ TriClover \/ 0.1% Acc No HART","offer_id":43002127909033,"sku":"CoriU-TC-1-0.1","price":9700.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ TriClover \/ 0.1% Acc w\/ HART","offer_id":43002127941801,"sku":"CoriU-TC-1-0.1-Hart","price":9900.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ ANSI 150# \/ 0.5% Acc No HART","offer_id":42082383364265,"sku":"CoriU-AN-1_1_2-0.5","price":7900.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ ANSI 150# \/ 0.5% Acc w\/ HART","offer_id":42082383397033,"sku":"CoriU-AN-1_1_2-0.5-Hart","price":8100.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ ANSI 150# \/ 0.2% Acc No HART","offer_id":43002127974569,"sku":"CoriU-AN-1_1_2-0.2","price":9200.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ ANSI 150# \/ 0.2% Acc w\/ HART","offer_id":43002128007337,"sku":"CoriU-AN-1_1_2-0.2-Hart","price":9400.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ ANSI 150# \/ 0.1% Acc No HART","offer_id":43002128040105,"sku":"CoriU-AN-1_1_2-0.1","price":11000.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ ANSI 150# \/ 0.1% Acc w\/ HART","offer_id":43002128072873,"sku":"CoriU-AN-1_1_2-0.1-Hart","price":11200.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ TriClover \/ 0.5% Acc No HART","offer_id":42082383429801,"sku":"CoriU-TC-1_1_2-0.5","price":7900.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ TriClover \/ 0.5% Acc w\/ HART","offer_id":42082383462569,"sku":"CoriU-TC-1_1_2-0.5-Hart","price":8100.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ TriClover \/ 0.2% Acc No HART","offer_id":43002128105641,"sku":"CoriU-TC-1_1_2-0.2","price":9200.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ TriClover \/ 0.2% Acc w\/ HART","offer_id":43002128138409,"sku":"CoriU-TC-1_1_2-0.2-Hart","price":9400.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ TriClover \/ 0.1% Acc No HART","offer_id":43002128171177,"sku":"CoriU-TC-1_1_2-0.1","price":11000.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ TriClover \/ 0.1% Acc w\/ HART","offer_id":43002128203945,"sku":"CoriU-TC-1_1_2-0.1-Hart","price":11200.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ ANSI 150# \/ 0.5% Acc No HART","offer_id":42082383495337,"sku":"CoriU-AN-2-0.5","price":10200.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ ANSI 150# \/ 0.5% Acc w\/ HART","offer_id":42082383528105,"sku":"CoriU-AN-2-0.5-Hart","price":10400.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ ANSI 150# \/ 0.2% Acc No HART","offer_id":43002128236713,"sku":"CoriU-AN-2-0.2","price":12300.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ ANSI 150# \/ 0.2% Acc w\/ HART","offer_id":43002128269481,"sku":"CoriU-AN-2-0.2-Hart","price":12500.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ ANSI 150# \/ 0.1% Acc No HART","offer_id":43002128302249,"sku":"CoriU-AN-2-0.1","price":14100.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ ANSI 150# \/ 0.1% Acc w\/ HART","offer_id":43002128335017,"sku":"CoriU-AN-2-0.1-Hart","price":14300.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ TriClover \/ 0.5% Acc No HART","offer_id":42082383560873,"sku":"CoriU-TC-2-0.5","price":10200.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ TriClover \/ 0.5% Acc w\/ HART","offer_id":42082383593641,"sku":"CoriU-TC-2-0.5-Hart","price":10400.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ TriClover \/ 0.2% Acc No HART","offer_id":43002128367785,"sku":"CoriU-TC-2-0.2","price":12300.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ TriClover \/ 0.2% Acc w\/ HART","offer_id":43002128400553,"sku":"CoriU-TC-2-0.2-Hart","price":12500.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ TriClover \/ 0.1% Acc No HART","offer_id":43002128433321,"sku":"CoriU-TC-2-0.1","price":14100.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ TriClover \/ 0.1% Acc w\/ HART","offer_id":43002128466089,"sku":"CoriU-TC-2-0.1-Hart","price":14300.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ ANSI 150# \/ 0.5% Acc No HART","offer_id":42082383626409,"sku":"CoriU-AN-3-0.5","price":13300.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ ANSI 150# \/ 0.5% Acc w\/ HART","offer_id":42082383659177,"sku":"CoriU-AN-3-0.5-Hart","price":13500.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ ANSI 150# \/ 0.2% Acc No HART","offer_id":43002128498857,"sku":"CoriU-AN-3-0.2","price":16400.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ ANSI 150# \/ 0.2% Acc w\/ HART","offer_id":43002128531625,"sku":"CoriU-AN-3-0.2-Hart","price":16600.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ ANSI 150# \/ 0.1% Acc No HART","offer_id":43002128564393,"sku":"CoriU-AN-3-0.1","price":17500.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ ANSI 150# \/ 0.1% Acc w\/ HART","offer_id":43002128597161,"sku":"CoriU-AN-3-0.1-Hart","price":17700.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ TriClover \/ 0.5% Acc No HART","offer_id":42082383691945,"sku":"CoriU-TC-3-0.5","price":13300.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ TriClover \/ 0.5% Acc w\/ HART","offer_id":42082383724713,"sku":"CoriU-TC-3-0.5-Hart","price":13500.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ TriClover \/ 0.2% Acc No HART","offer_id":43002128629929,"sku":"CoriU-TC-3-0.2","price":16400.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ TriClover \/ 0.2% Acc w\/ HART","offer_id":43002128662697,"sku":"CoriU-TC-3-0.2-Hart","price":16600.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ TriClover \/ 0.1% Acc No HART","offer_id":43002128695465,"sku":"CoriU-TC-3-0.1","price":17500.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ TriClover \/ 0.1% Acc w\/ HART","offer_id":43002128728233,"sku":"CoriU-TC-3-0.1-Hart","price":17700.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ ANSI 150# \/ 0.5% Acc No HART","offer_id":42082383757481,"sku":"CoriU-AN-4-0.5","price":21300.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ ANSI 150# \/ 0.5% Acc w\/ HART","offer_id":42082383790249,"sku":"CoriU-AN-4-0.5-Hart","price":21500.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ ANSI 150# \/ 0.2% Acc No HART","offer_id":43002128761001,"sku":"CoriU-AN-4-0.2","price":25400.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ ANSI 150# \/ 0.2% Acc w\/ HART","offer_id":43002128793769,"sku":"CoriU-AN-4-0.2-Hart","price":25600.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ ANSI 150# \/ 0.1% Acc No HART","offer_id":43002128826537,"sku":"CoriU-AN-4-0.1","price":30500.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ ANSI 150# \/ 0.1% Acc w\/ HART","offer_id":43002128859305,"sku":"CoriU-AN-4-0.1-Hart","price":30700.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ TriClover \/ 0.5% Acc No HART","offer_id":42082383823017,"sku":"CoriU-TC-4-0.5","price":21300.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ TriClover \/ 0.5% Acc w\/ HART","offer_id":42082383855785,"sku":"CoriU-TC-4-0.5-Hart","price":21500.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ TriClover \/ 0.2% Acc No HART","offer_id":43002128892073,"sku":"CoriU-TC-4-0.2","price":25400.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ TriClover \/ 0.2% Acc w\/ HART","offer_id":43002128924841,"sku":"CoriU-TC-4-0.2-Hart","price":25600.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ TriClover \/ 0.1% Acc No HART","offer_id":43002128957609,"sku":"CoriU-TC-4-0.1","price":30500.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ TriClover \/ 0.1% Acc w\/ HART","offer_id":43002128990377,"sku":"CoriU-TC-4-0.1-Hart","price":30700.0,"currency_code":"USD","in_stock":true},{"title":"6\" ANSI Only \/ ANSI 150# \/ 0.5% Acc No HART","offer_id":42082383888553,"sku":"CoriU-AN-6-0.5","price":27300.0,"currency_code":"USD","in_stock":true},{"title":"6\" ANSI Only \/ ANSI 150# \/ 0.5% Acc w\/ HART","offer_id":42082383921321,"sku":"CoriU-AN-6-0.5-Hart","price":27500.0,"currency_code":"USD","in_stock":true},{"title":"6\" ANSI Only \/ ANSI 150# \/ 0.2% Acc No HART","offer_id":43002129023145,"sku":"CoriU-AN-6-0.2","price":33100.0,"currency_code":"USD","in_stock":true},{"title":"6\" ANSI Only \/ ANSI 150# \/ 0.2% Acc w\/ HART","offer_id":43002129055913,"sku":"CoriU-AN-6-0.2-Hart","price":33300.0,"currency_code":"USD","in_stock":true},{"title":"6\" ANSI Only \/ ANSI 150# \/ 0.1% Acc No HART","offer_id":43002129088681,"sku":"CoriU-AN-6-0.1","price":39300.0,"currency_code":"USD","in_stock":true},{"title":"6\" ANSI Only \/ ANSI 150# \/ 0.1% Acc w\/ HART","offer_id":43002129121449,"sku":"CoriU-AN-6-0.1-Hart","price":39500.0,"currency_code":"USD","in_stock":true},{"title":"8\" ANSI Only \/ ANSI 150# \/ 0.5% Acc No HART","offer_id":42082384019625,"sku":"CoriU-AN-8-0.5","price":48400.0,"currency_code":"USD","in_stock":true},{"title":"8\" ANSI Only \/ ANSI 150# \/ 0.5% Acc w\/ HART","offer_id":42082384052393,"sku":"CoriU-AN-8-0.5-Hart","price":48600.0,"currency_code":"USD","in_stock":true},{"title":"8\" ANSI Only \/ ANSI 150# \/ 0.2% Acc No HART","offer_id":43002129154217,"sku":"CoriU-AN-8-0.2","price":52500.0,"currency_code":"USD","in_stock":true},{"title":"8\" ANSI Only \/ ANSI 150# \/ 0.2% Acc w\/ HART","offer_id":43002129186985,"sku":"CoriU-AN-8-0.2-Hart","price":52700.0,"currency_code":"USD","in_stock":true},{"title":"8\" ANSI Only \/ ANSI 150# \/ 0.1% Acc No HART","offer_id":43002129219753,"sku":"CoriU-AN-8-0.1","price":55900.0,"currency_code":"USD","in_stock":true},{"title":"8\" ANSI Only \/ ANSI 150# \/ 0.1% Acc w\/ HART","offer_id":43002129252521,"sku":"CoriU-AN-8-0.1-Hart","price":56100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Coriolis_Mass_Flow_Meter_Type_M_Straight.webp?v=1757972371"},{"product_id":"mems-thermal-mass-flow-meter-natural-gas","title":"Thermal Mass Flow Meter \u003cbr\u003efor Gas Flow (Methane and Natural Gas) \u003cbr\u003e1\/2\" to 2\" NPT","description":"\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eOur thermal Flow meters feature our proprietary MEMS time-of-flight mass flow sensor installed in a laminar flow channel that forms a boundary layer ensuring laminar flow exists in the desired measurement area.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eA thermal time-of-flight meter works well for methane and natural gas applications because it directly measures gas mass flow based on heat transfer, making it highly accurate even at low flow rates and low pressures, without needing external temperature or pressure compensation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThermal time-of-flight meters work well for boilers because they accurately measure flow in high-temperature, variable conditions without obstructing the flow or being affected by pressure and density changes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eConventional thermal mass flow meters have sensitivity to the thermal properties of the gas as well as to the gas flow conditions. Our time of flight mass flow meter, utilizing the time of flight of micro pulses of thermal bursts of energy, has no sensitivity to temperature or gas properties when the system is “zeroed” in the desired gas. It is a pure “mass velocity” measuring machine that does not care about gas temperature or composition.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eTime of Flight Thermal mass flow meters for gases and air shipping from stock \u0026amp; configured for you. OEM customers welcome.\u003cbr\u003e\u003cbr\u003eEASY to use Low Flow Mass Flow Meters. Check our stock \u0026amp; prices that beats our competition\u003c\/span\u003e\u003c\/p\u003e\n\u003c!--split--\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003eThermal Mass Flow Meter Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM-5700-Specifications.png?v=1727910226\" alt=\"Thermal Flow Meter Specifications\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003ch3\u003eNatural Gas Flow Meter Features\u003c\/h3\u003e\n\u003cdiv class=\"product-bullet-list\"\u003e\n\u003cul\u003e\n\u003cli\u003eNatural Gas Flow Meter for burners.\u003c\/li\u003e\n\u003cli\u003eMethane Gas Flow Meter for Billing\u003c\/li\u003e\n\u003cli\u003eGeneral purpose gas mass flow meter\u003c\/li\u003e\n\u003cli\u003eFast response time, customizable to 1 msec\u003c\/li\u003e\n\u003cli\u003eIP55 \/ NEMA  enclosure\u003c\/li\u003e\n\u003cli\u003eLarge dynamic range, over 100:1 S\u003c\/li\u003e\n\u003cli\u003eSerial, Analog and LCD interface\u003c\/li\u003e\n\u003cli\u003eCustomer accessible 3 button user Interface\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cspan\u003e\u003cstrong\u003eInstructions\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003ca rel=\"noopener noreferrer\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Quick_Manual_TFM5700_TOF_Series_Rev_3.4.pdf?v=1657903065\" title='Inline Methane and Natural Gas Mass Flow Meter 1\/2\" to 2\" NPT' target=\"_blank\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #2b00ff;\"\u003eTFM Thermal Meter Manual \u003c\/span\u003e\u003c\/strong\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg alt=\"Methane Flow Meter Part Number System\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Methane_Mass_Flow_Meter_Part_Numbers_600x600.png?v=1613604488\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM-5700_TOF_Meter_Brochure-R4_24426710-2073-49e2-a59e-30cfca8218ba.pdf?v=1613593798\" title=\"Inline Methane and Natural Gas Flow Meter Brochure\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eSeries TFM-5700 Brochure for Methane Mass Flow Meter\u003cbr\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eGas Conversion Factor\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eThe \u003cspan class=\"Yjhzub\"\u003eGas Conversion Factor (GCF)\u003c\/span\u003e is used to adjust flow readings when the meter is measuring a gas different from its default calibration gas (usually \u003cspan class=\"Yjhzub\"\u003eAir\u003c\/span\u003e or \u003cspan class=\"Yjhzub\"\u003eNitrogen\u003c\/span\u003e). Because different gases have unique thermal properties, such as density and specific heat, applying the correct GCF ensures measurement accuracy across various media\u003c\/p\u003e\n\u003ctable height=\"586\" data-sae=\"\" data-animation-nesting=\"\" style=\"border-collapse: collapse; width: 305px;\" width=\"303\" cellspacing=\"0\" cellpadding=\"0\" border=\"0\"\u003e\n\u003ccolgroup\u003e \u003ccol style=\"width: 106.333px;\" width=\"106\"\u003e \u003ccol style=\"width: 132.333px;\" width=\"133\"\u003e \u003ccol style=\"width: 64.3333px;\" width=\"64\"\u003e \u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 30.0pt;\" height=\"40\"\u003e\n\u003ctd style=\"height: 30.0pt; width: 80pt;\" width=\"106\" class=\"xl65\" height=\"40\"\u003e\u003cstrong\u003eGas\u003cspan data-complete=\"true\" data-wiz-uids=\"kCnIpc_z,kCnIpc_10\"\u003e\u003c!--Sv6Kpe[[null,null,\u0026quot;2e2e6e83-1f03-41d4-aabf-3f51adbcf22f\u0026quot;,null,null,0,0,\u0026quot;\u0026quot;,\u0026quot;\u0026quot;]]--\u003e\u003c\/span\u003e\u003c!--Sv6Kpe[]--\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-left: none; width: 100pt;\" width=\"133\" class=\"xl65\"\u003e\u003cstrong\u003eConversion Factor (GCF)\u003c!--Sv6Kpe[]--\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"border-left: none; width: 48pt;\" width=\"64\" class=\"xl65\"\u003e\u003cstrong\u003eMenu Setting\u003c\/strong\u003e\u003c\/td\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003c\/tr\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003ctr data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 15.0pt; border-top: none; width: 80pt;\" width=\"106\" align=\"left\" class=\"xl66\" height=\"20\"\u003eAir\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"border-top: none; border-left: none; width: 100pt;\" width=\"133\" class=\"xl65\"\u003e1\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"border-top: none; border-left: none; width: 48pt;\" width=\"64\" class=\"xl65\"\u003e1000\u003c\/td\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003c\/tr\u003e\n\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e\n\u003ctr data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 45.0pt; border-top: none; width: 80pt;\" width=\"106\" align=\"left\" class=\"xl66\" height=\"60\" rowspan=\"3\"\u003eNitrogen\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 100pt;\" width=\"133\" class=\"xl67\" rowspan=\"3\"\u003e\n\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e1\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"border-top: none; width: 48pt;\" width=\"64\" class=\"xl67\" rowspan=\"3\"\u003e1000\u003c\/td\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003c\/tr\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 45.0pt; border-top: none; width: 80pt;\" width=\"106\" align=\"left\" class=\"xl66\" height=\"60\" rowspan=\"3\"\u003eOxygen\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 100pt;\" width=\"133\" class=\"xl67\" rowspan=\"3\"\u003e\n\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e0.99\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"border-top: none; width: 48pt;\" width=\"64\" class=\"xl67\" rowspan=\"3\"\u003e990\u003c\/td\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003c\/tr\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 45.0pt; border-top: none; width: 80pt;\" width=\"106\" align=\"left\" class=\"xl66\" height=\"60\" rowspan=\"3\"\u003eArgon\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 100pt;\" width=\"133\" class=\"xl67\" rowspan=\"3\"\u003e\n\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e1.45\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"border-top: none; width: 48pt;\" width=\"64\" class=\"xl67\" rowspan=\"3\"\u003e1450\u003c\/td\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003c\/tr\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 45.0pt; border-top: none; width: 80pt;\" width=\"106\" align=\"left\" class=\"xl66\" height=\"60\" rowspan=\"3\"\u003eHelium\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 100pt;\" width=\"133\" class=\"xl67\" rowspan=\"3\"\u003e\n\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e1.45\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"border-top: none; width: 48pt;\" width=\"64\" class=\"xl67\" rowspan=\"3\"\u003e1450\u003c\/td\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003c\/tr\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 45.0pt; border-top: none; width: 80pt;\" width=\"106\" align=\"left\" class=\"xl66\" height=\"60\" rowspan=\"3\"\u003eCarbon Dioxide\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 100pt;\" width=\"133\" class=\"xl67\" rowspan=\"3\"\u003e\n\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e0.74\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"border-top: none; width: 48pt;\" width=\"64\" class=\"xl67\" rowspan=\"3\"\u003e740\u003c\/td\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003c\/tr\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 45.0pt; border-top: none; width: 80pt;\" width=\"106\" align=\"left\" class=\"xl66\" height=\"60\" rowspan=\"3\"\u003eMethane\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 100pt;\" width=\"133\" class=\"xl67\" rowspan=\"3\"\u003e\n\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e0.72\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"border-top: none; width: 48pt;\" width=\"64\" class=\"xl67\" rowspan=\"3\"\u003e720\u003c\/td\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003c\/tr\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 45.0pt; border-top: none; width: 80pt;\" width=\"106\" align=\"left\" class=\"xl66\" height=\"60\" rowspan=\"3\"\u003eAmmonia\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 100pt;\" width=\"133\" class=\"xl67\" rowspan=\"3\"\u003e\n\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e0.73\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"border-top: none; width: 48pt;\" width=\"64\" class=\"xl67\" rowspan=\"3\"\u003e730\u003c\/td\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003c\/tr\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 45.0pt; border-top: none; width: 80pt;\" width=\"106\" align=\"left\" class=\"xl66\" height=\"60\" rowspan=\"3\"\u003ePropane\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 100pt;\" width=\"133\" class=\"xl67\" rowspan=\"3\"\u003e\n\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e0.36\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"border-top: none; width: 48pt;\" width=\"64\" class=\"xl67\" rowspan=\"3\"\u003e360\u003c\/td\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003c\/tr\u003e\n\u003c!--Sv6Kpe[]--\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 15.0pt;\" height=\"20\"\u003e\n\u003ctd data-complete=\"true\" data-sfc-cp=\"\" style=\"height: 45.0pt; border-top: none; width: 80pt;\" width=\"106\" align=\"left\" class=\"xl66\" height=\"60\" rowspan=\"3\"\u003eHydrogen\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-top: none; width: 100pt;\" width=\"133\" class=\"xl67\" rowspan=\"3\"\u003e\n\u003c!--Sv6Kpe[]--\u003e\u003c!--Sv6Kpe[]--\u003e1.01\u003c!--Sv6Kpe[]--\u003e\n\u003c\/td\u003e\n\u003ctd aria-owns=\"action-menu-parent-container\" data-complete=\"true\" data-sfc-cp=\"\" style=\"border-top: none; width: 48pt;\" width=\"64\" class=\"xl67\" rowspan=\"3\"\u003e1010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003ctr style=\"height: 15.0pt;\" height=\"20\"\u003e\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch5\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003eFeatures LARGE LCD display, shows the Flow Rate, Total Flow\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Methane_Mass_Flow_Meter_User_Interface_480x480.png?v=1613604325\" alt=\"Natural Gas Flow Meter Display\" loading=\"lazy\"\u003e\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eThe TFM-5700 Methane Flow meter outputs mass flow rate, total and outputs 4-20 mA as well as ModBUS RTU.\u003c\/b\u003e\u003c\/p\u003e\n\u003ch3\u003eMethane Mass Flow Meter Flow Ranges\u003c\/h3\u003e\n\u003ctable height=\"166\" width=\"562\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 552px;\"\u003e\n\u003cp\u003e\u003cb\u003e1\/2\" NPT TMF5700 Flow Meter 0-20 SCFH, \u003cbr\u003e0- 0.33 SCFM \u003c\/b\u003e\u003cb\u003eor \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e1\/2\" NPT TMF5700 Flow Meter 0-650 SCFH, \u003cbr\u003e0- 10.8 SCFM\u003c\/b\u003e\u003cb\u003e \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e1\" NPT TMF5700 Flow Meter 0-240 SCFH, \u003cbr\u003e0- 41.2 SCFM \u003c\/b\u003e\u003cb\u003eor \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e1\" NPT TMF5700 Flow Meter 0-2500 SCFH, \u003cbr\u003e0- 41.6 SCFM\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e2\" NPT TMF5700 Flow Meter 0-3000 SCFH, \u003cbr\u003e0- 50 SCFM \u003c\/b\u003e\u003cb\u003eor \u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003e2\" NPT TMF5700 Flow Meter 0-6200 SCFH, \u003cbr\u003e0- 103 SCFM\u003c\/b\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eNote: The maximum \"safe velocity\" within a pipe for natural gas and other flammable hydrocarbons is 30 m\/s\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv class=\"cgt-content\" style=\"text-align: start;\"\u003e\n\u003ch3\u003eMethane and Natural Gas Flow Meter Dimensions\u003ca title='2\" NPT Methane Mass Flow Meter Dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM-5700_Meter_Dimensions_R_1.pdf?v=1613594595\"\u003e\u003cbr\u003e\u003cimg style=\"color: #212b36; font-family: -apple-system, BlinkMacSystemFont, 'San Francisco', 'Segoe UI', Roboto, 'Helvetica Neue', sans-serif; font-size: 1.4em;\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Methane_and_Natural_Gas_Flow_Meter_Dimensions_for_1_and_2_Inch_NPT_600x600.png?v=1613594517\" alt='1\" and 2\" NPT Methane and Natural Gas Flow Meter Dimensions' loading=\"lazy\"\u003e\u003cbr\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca title=\"Methane and Natural Gas Flow Meter Dimensions for 1 and 2 inch NPT sizes\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM-5700_Meter_Dimensions_R_1.pdf?v=1613594595\" style=\"color: #2b00ff;\" target=\"_blank\"\u003eMethane and Natural Gas Flow Meter Dimensions link\u003cbr\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch5\u003e\n\u003cstrong\u003eWiring Guide\u003c\/strong\u003e\u003cspan style=\"color: #000000;\"\u003e\u003c\/span\u003e\n\u003c\/h5\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Wiring_Guide_480x480.png?v=1614186623\" alt=\"Natural Gas Flow Meter Wiring Guide\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: start;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Natural_Gas_Flowmeter_Wiring_Description_98b33e92-a68b-4177-9dad-5ee55ced8c41_1024x1024.png?v=1614186876\" alt=\"Natural Gas Flow Meter Wiring Guide\" loading=\"lazy\"\u003e\u003c\/div\u003e\n\u003cstrong\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TFM-5700_TOF_Meter_Brochure-R4_24426710-2073-49e2-a59e-30cfca8218ba.pdf?v=1613593798\" title=\"Inline Methane and Natural Gas Flow Meter Brochure\" style=\"color: #2b00ff;\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eTheory\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch4\u003e\u003cstrong\u003eTFM-5700 Series Natural Gas Flow Meter Principle of Operation:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eOur TFM-5700 TOF Mass Flow meters feature our proprietary and state-of-the-art MEMS thermal time-of-flight mass flow sensor installed in a laminar flow channel that forms a boundary layer ensuring laminar flow exists in the desired measurement area.\u003cbr\u003e\u003cbr\u003eThe flow measurement, using our innovative time of flight MEMS technology, provides superior accuracy over conventional thermal mass flow meters. We utilize a a very low power micro heater that is pulsed where we measure the time the pulse takes to arrive at the measuring point located a precise distance away. The flow meter is a \"mass velocity measuring machine\" that measures the gas thermal properties to extract the density for true Mass Flow Rate Indication.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Time-Of-Flight_Graphic.png?v=1613605916\" alt=\"Time of Flight Flow Meter\" style=\"width: 145px; height: 189px; object-fit: contain;\" loading=\"lazy\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhy is this an improvement over conventional Thermal Mass Flow Meters?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eConventional thermal mass flow meters have sensitivity to the thermal properties of the gas as well as to the gas flow conditions. Our time of flight mass flow meter, utilizing the time of flight of micro pulses of thermal bursts of energy, has no sensitivity to temperature or gas properties when the system is \"zeroed\" in the desired gas.\u003cbr\u003e\u003cbr\u003eIt is a pure \"mass velocity\" measuring machine that does not care about gas temperature or composition. Consider conventional thermal mass flow meters you may have used in the past that have to be calibrated for the specific gas and do not do well when the temperature of the gas changes rapidly.\u003cbr\u003e\u003cbr\u003eThe TFM-5700 series of Mass Flow Meters has no such sensitivity. As well, these meters are blazing fast compared to conventional thermal mass flow meters, and they take VERY VERY VERY little power to run.\u003cbr\u003e\u003cbr\u003eNote: Our thermal mass flow meters are an improvement to most \"top brand\" flow meters on the market, we invite you to investigate them. \u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Power_Supplies_Bolts_Gaskets_and_more.pdf?v=1605288973\" title=\"Where to get 24 VDC Power Supplies and flange bolts and gaskets\" target=\"_blank\"\u003eWhere to get Power Supplies, Gaskets, Nuts and Bolts\u003c\/a\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003ch5\u003e\u003cstrong\u003eVideos\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch4\u003eModBUS RTU quick video:\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eSimple instructions and details regarding the use of ModBus RTU with the TFM5700 Series Methane and Natural Gas Mass Flow Meter flow meter..\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"ENp5nBIAs2Q\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/ENp5nBIAs2Q\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eVideo Below showing our Generic ModBus Program:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"3yBtgBUG_Zk\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/3yBtgBUG_Zk\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Tactical Flow Meter","offers":[{"title":"1\/2\" 0-20 SCFH (0-0.33 SCFM)","offer_id":41700698194089,"sku":"TFM5700-BASE","price":1400.0,"currency_code":"USD","in_stock":true},{"title":"1\" 0-240 SCFH (0-4 SCFM)","offer_id":41700742037673,"sku":"TFM5700-BASE-7","price":1500.0,"currency_code":"USD","in_stock":true},{"title":"1\" 0-300 SCFH (0-5 SCFM)","offer_id":41700714053801,"sku":"TFM5700-BASE-6","price":1500.0,"currency_code":"USD","in_stock":true},{"title":"1\" 0-1200 SCFH (0-10 SCFM)","offer_id":41700698226857,"sku":"TFM5700-BASE-2","price":1500.0,"currency_code":"USD","in_stock":true},{"title":"1\" 0-3000 SCFH (0-50 SCFM)","offer_id":41700698259625,"sku":"TFM5700-BASE-3","price":1500.0,"currency_code":"USD","in_stock":true},{"title":"2\" 0-3000 SCFH (0-50 SCFM)","offer_id":41700698292393,"sku":"TFM5700-BASE-4","price":2000.0,"currency_code":"USD","in_stock":true},{"title":"2\" 0-10000 SCFH (0-166 SCFM)","offer_id":41700698325161,"sku":"TFM5700-BASE-5","price":2000.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/NaturalGasFlowMeter0.5InchClean6_60086805-e313-485b-be27-6035075dd537.png?v=1629501026"},{"product_id":"inline-ultrasonic-flow-meter","title":"Inline Ultrasonic Flow Meter \u003cbr\u003efor Liquid Flow \u003cbr\u003e1\/2\" to 6\"","description":"\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eInline ultrasonic flow meters use sound waves transmitted through the fluid to measure flow rate directly in a fixed pipe section. They offer high accuracy, low pressure drop, and no moving parts, making them ideal for clean liquids. Benefits include minimal maintenance, excellent long-term stability, and suitability for sanitary or corrosive environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eInline ultrasonic flow meters work well in challenging applications like flare gas, where traditional meters struggle due to variable flow rates, changing gas composition, and low pressures. They're also effective in custody transfer of natural gas, process control in petrochemical plants, and compressed air systems. Their non-intrusive measurement and ability to handle wide turndown ratios make them ideal for leak detection, waste gas monitoring, and low-flow vapor measurement, especially in harsh or hazardous environments. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eInline Ultrasonic Flow Meters at the prices of High-End Clamp On Ultrasonic Flow Meters and feature accuracies of 0.5% of READING. Ideal for DI Water and many fluids that the MAG meter can not measure due to low electrical conductivity. Perfect for oils such as Diesel Oil and many other oils.\u003cbr\u003e\u003cb\u003e\u003cbr\u003eFeatures LARGE LCD display, shows the Instantaneous Flow Rate, Total Flow, in user selectable units.\u003c\/b\u003e \u003cbr\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c!--split--\u003e\n\u003ch5\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch6 style=\"font-size: 1.17em; font-weight: bold; margin: 1em 0;\"\u003eInline Ultrasonic Flow Meter Specifications\u003c\/h6\u003e\n\u003cdiv class=\"product-bullet-list\"\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eFlow Body material: 304 SS\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMedium: Any acoustically conductive liquid with less than 5% air bubbles or solids \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFlow Range: Supports velocities up to  40 f\/s or 12 m\/s \u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eAccuracy: ±1% from 0.15 to 40 f\/s (0.05 to 12 m\/s)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eResolution: 0.01 ft\/s (0.00025 m\/s)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eResponse time: 150 ms measuring cycle typical\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePipe size: 1” to 6”, custom up to 12\"\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eTemperature: - 20 - 110 ℃\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eTransducer Frequency: 1 MHz\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003eStd Temp Spec for Transmitters: 320 F (160 C)\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eEnclosure Grade: IP65\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eDisplay LCD Screen\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePower Supply: Set up to use either 24VDC or a 86-240 VAC Universal Power Supply. Only one at a time. Consumes 500 mA max\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eOutput: 4-20mA + 0-10K Hz + Standard ModBus RTU Communication protocol\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eNote: For 1 to 5 VDC output, add 250 Ohm resistor to 4 to 20 mA loop\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eInstructions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003e\u003ca title=\"Inline Ultrasonic Flow Meter Quick User Manual\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Inline_Ultrasonic_user_manual_R-1d.pdf?v=1638580629\"\u003eTFM Inline Ultrasonic Manual\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Quick_ultrasonic_flow_meter_Style_2_user_Manual_R16.pdf?v=1591375140\" title=\"Ultrasonic Flow Meter Quick User Manual\" target=\"_blank\"\u003e\u003cbr\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch5\u003e\u003cstrong\u003eFlow Rates\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eInline Ultrasonic flow meters (Ultrasonic flow meters) are volumetric flow meters for measuring acoustically conductive fluids [Not Gases] that operate without any moving parts and are ideal for potable water and wastewater applications as well as ideal for any non conductive or water based clean or dirty fluid.  Ultrasonic flow meters will work with hydrocarbons, distilled water, DI water, and many non-aqueous solutions where the MAG meter is not capable or performing.\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe table below gives a guideline of the nominal maximum GPM for various pipe sizes. \u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003eFlows in well designed piping systems, to minimize wear and noise, and energy, are typically no more than 10 m\/s max.\u003c\/strong\u003e\u003c\/span\u003e Note these meters can easily go to 12 m\/s for systems, such as high pressure fire fighting systems and blowdown systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg loading=\"lazy\" alt=\"Ultrasonic Flow Meter Flow Rate Chart\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Mag-Meter-FlowRate-Chart-TacticalFlowMeter_0.3_to_12mps_d1d83023-3dcd-43f7-b0f4-529eafcf46c4.png\" class=\"responsive-content-image\"\u003e\u003c\/div\u003e\n\u003ch5\u003e\u003cstrong\u003eCut Sheet\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003e\u003cspan\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Cut_Sheet_Ultrasonic_Flow_Meter_R0.pdf?v=1595279214\" title=\"Ultrasonic Cut Sheet\" target=\"_blank\"\u003eUltrasonic Cut Sheet\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003ch5\u003e\u003cstrong\u003eCheat Sheet\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch3\u003e\n\u003ca title=\"Ultrasonic Installing Cheat Sheet\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Inline_Ultrasonic_user_manual_R-1c_e3682a6c-a9a2-4182-a15a-3156ce5fc4a7.pdf?v=1638579927\" target=\"_blank\"\u003eUltrasonic Installing Cheat Sheet\u003c\/a\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\u003c\/ul\u003e\n\u003ch5\u003e\u003cstrong\u003eQuick Notes\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch4\u003e\u003cspan\u003e\u003cstrong\u003eHELPFUL QUICK NOTES: Menu 90 shows Signal Strength and Menu 00 shows main flow rate and total.\u003c\/strong\u003e  Also set menu 40, the Filter Coefficient, (We could call this the time constant or response time), with Menu 40 to 1 second to make the meter respond quickly. Then, put back to 4 seconds and save with Menu 26 and hit enter twice. Menu 45 is for entering a K-Factor, this would be handy if you KNOW the flow is 90 when it says 100. In this case a K-Factor of 0.9 would remedy it. (Ideally the distances and pipe thickness\/material would be corrected but this is easier). Menu 70 and 71 allow LCD Display on time and contrast respectively\u003c\/span\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003e§3.1.6 Validating meter function.\u003c\/strong\u003e\u003cbr\u003eEntering a pipe outer diameter (Menu 11) of zero, results in the display to show the flow velocity: 1.2345678m\/s (4.0504ft\/s) [use down arrow to view], flow rate= will vary, and display “R”status on Menu 00. Inputting a set value in M44 will change the totalizer output. Use this function to test of the flow meter and network software without having to connect the transducers. If they are connected the flow rate may be + or -\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch2 style=\"text-align: left;\"\u003eInline Ultrasonic Meter Dimensions\u003ca title='1\/2\" to 12\" MAG Meter Dimensions' href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R4.pdf?v=1588134523\"\u003e\u003cimg loading=\"lazy\" alt='1\/2\" to 12\" MAG Meter Dimensions' data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/MagMeterDimensions1Inch_to_12_Inch.png\" class=\"responsive-content-image\"\u003e\u003c\/a\u003e\n\u003c\/h2\u003e\n\u003ch5 style=\"text-align: left;\"\u003e\u003cstrong\u003ePlumbing\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Standard_SS304_Flange_type_stocked_MAG_meters_R2.pdf?172\" title=\"MAG Meter dimensions and installation requirements\" target=\"_blank\"\u003eMAG Meter dimensions\/ Installation requirements\u003c\/a\u003e\u003c\/strong\u003e\u003c\/div\u003e\n\u003cp\u003eFlow Meter Installation requirements:\u003c\/p\u003e\n\u003cp\u003eThe video above shows how to set up the meter for Pulse and Frequency and shows how the 4-20 mA is configured. \u003c\/p\u003e\n\u003cp\u003eSimulating and validating the 4-20 mA output using the User Interface with 03210 is detailed below. You may ALTER these values (AnalogZero and AnlgRange) using 03210 and they will revert when you exit.\u003c\/p\u003e\n\u003cp\u003eNote the 4-20 mA output for this meter is POWERED by the meter. DO NOT connect to a PLC that provides 24 VDC. Connection is made to the 4-20 mA signal using a reading mode just like a Fluke Meter configured to read 4-20 mA DC. The MAG meter provides the 24 VDC for outputting the value to the INPUT of your PLC. Every PLC has the ability to be configured to read this type of 4-20 mA output. (Note: From the main menu the AnalogZero is 49 hits of the UP arrow.) (ADJUSTMENT of the 4-20 Output drive is attained using secret password of 19818 and is risky to use.)\u003cstrong\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003cstrong\u003ePressure Ratings\u003c\/strong\u003e\u003ca title=\"Inline Ultrasonic-Meter-Quick-User-Manual-and-Wiring-Instructions\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Inline_Ultrasonic_user_manual_R-1d.pdf?v=1638580629\" target=\"_blank\"\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/h5\u003e\n\u003ch3\u003eFlange Pressure Ratings Chart:\u003c\/h3\u003e\n\u003cp\u003e\u003cimg loading=\"lazy\" alt=\"ANSI Class Rating Chart from Class 150 to Class 2500\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/ANSI_CLASS_Flange_Pressure_Ratings_Chart.png\" class=\"responsive-content-image\"\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eSpeed of Sound\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch2\u003eUltrasonic Flow Meter Sound Speed for various fluids.\u003c\/h2\u003e\n\u003cp\u003eRefer to this chart to ensure your fluid has sufficient conductivity to honor Faraday's Law that is the essence of the MAG Meter\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/SoundSpeedMaterials.png?3247770073703420262\" title=\"Sound Speed of Various Materials\" target=\"_blank\"\u003e\u003cimg loading=\"lazy\" alt=\"Sound Speed Various Materials\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/SoundSpeedMaterials.png\" class=\"responsive-content-image\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eTheory\u003c\/strong\u003e\u003c\/h5\u003e\n\u003ch2\u003eUltrasonic Flow Meter Theory and Wiring \u003c\/h2\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Flow_Sensor_Principle_Simplified_R2.pdf?v=1663606812\" title=\"PDF Theory of How Ultrasonic Flow Meters Work\"\u003e Theory of Ultrasonic Flow Meters PDF\u003c\/a\u003e\u003c\/p\u003e\n\u003ch5\u003e\u003cstrong\u003eVideos\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e \u003cstrong\u003eSee videos below:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe videos peertain top the Clamp on Ultrasonic as well as the inline ultrasonic as they use the smae \"engine\"\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003e\u003cstrong\u003eHELPFUL QUICK NOTES: Menu 90 shows Signal Strength and Menu 00 shows main flow rate and total. \u003c\/strong\u003eMenu 40, the Filter Coefficient, (We could call this the time constant or response time), with Menu 40 to 1 second to make the meter respond quickly. Then, put back to 4 seconds and save with Menu 26 and hit enter twice. Menu 45 is for entering a K-Factor, this would be handy if you KNOW the flow is 90 when it says 100. In this case a K-Factor of 0.9 would remedy it. (Ideally the distances and pipe thickness\/material would be corrected but this is easier). Menu 70 and 71 allow LCD Display on time and contrast respectively. Note for Password Menu 47 System Lock unlock code is 8758 \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003ePASSWORD = 8758\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003eK-Factor\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003eThere is a Scale or K-Factor at Menu 45 that you may wish to invoke if you know a flow to be 1.10 units and we say is is 1.00 units then you can adjust Menu 45 to 1.1 to have the meter agree with a standard you believe to be true and correct. After setting this value invoke Menu 25 with two Enter hits and then get back to the main menu with menu 00. Note: The Scale, or K-Factor can go from 0.5 to 1.5.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003e\u003c\/span\u003e\u003cspan style=\"color: #2b00ff; background-color: #ffff00;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eReset totalizers with Menu 37\u003c\/span\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003e\u003cstrong\u003e§3.1.6 Validating meter function.\u003c\/strong\u003e\u003cbr\u003eEntering a pipe outer diameter (Menu 11) of zero, results in the display to show the flow velocity: 1.2345678m\/s (4.0504ft\/s) [use down arrow to view], flow rate= will vary, and display “R” status on Menu 00. Inputting a set value in M44 will change the flow rate output. Use this function to test of the flow meter and network software without having to connect the transducers. If they are connected the flow rate may be + or - \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #2b00ff;\"\u003eNote: Menu 44 allows setting up a ZERO value so that you can simulate flow. Entering a - (negative) value allows the flow to indicate positive. Be sure to put Menu 44 back to 0 when done simulating.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eSimple Overview how Ultrasonic Flow Meters Work. See the PDF below as well.\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Flow_Sensor_Principle_Simplified_R2.pdf?v=1663606812\" title=\"PDF of How Ultrasonic Flow Meters Work\"\u003ePDF of How Ultrasonic Flow Meters Work\u003c\/a\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"UtgkIFGB358\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/UtgkIFGB358\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eSuper Simple example for parsing data from ModBus showing a fixed value and a changing value.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"WURWJ3lkDQQ\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/WURWJ3lkDQQ\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eUltrasonic Meter setup verification and overview of menus for \u003cstrong\u003eDOSING\u003c\/strong\u003e or \u003cstrong\u003eMETERING\u003c\/strong\u003e functions. The video below called \"\u003cmeta charset=\"utf-8\"\u003e\u003cstrong\u003eVideo showing How to connect 4-20 mA on the Ultrasonic Flow Meter\u003c\/strong\u003e\" shows more details about pipe type and fluid selection in the 4-20 mA. Please watch this quick video and do not forget about Menu 26.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"1LRB8Lk5WYc\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/1LRB8Lk5WYc\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eHow to make a Batch Controller with an Ultrasonic Flow Meter:\u003cbr\u003eNote: Menu 78 allows you to select the OCT (Open Collector Transistor) and\/or the Relay Output contact closure at pins 30 and 31 under menu 79 \u003cstrong\u003eRELAY Output Setup.\u003c\/strong\u003e Use selection \u003cstrong\u003e21: Batch Total Full.\u003c\/strong\u003e Remember: Select Menu 26 and hit ENT TWICE after making changes to SAVE your settings.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"pKgFyOrjLuo\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/pKgFyOrjLuo\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003eVideo showing How to connect 4-20 mA on the Ultrasonic Flow Meter\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"DGmE37iVNCA\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/DGmE37iVNCA\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cimg loading=\"lazy\" alt=\"Ultrasonic Flow Meter Wiring for 4-20 mA output\" data-base=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Flow_Meter_Wiring_4-20_mA.png\" class=\"responsive-content-image\"\u003e\u003c\/p\u003e\n\u003cp\u003eHow to Factory Reset the Meter Values if you discover unknown variables were changed. Note: Doing so retains the timing calibration elements but reverts to factory values that require selecting the language, units, transducer type, and all the pipe and fluid settings. We show this using Menu 37 twice, once to reset and the next to select the language, and then using Menu 30 to select the units, then 23 for the transducer type, then 70 to have the LCD Backlight stay on 999 seconds, and then on to menu 11 and the associated menus such as 77, we do not show menu 55 and associated menus for the 4-20 output. Remember Menu 26 TWICE to save your changes. Use the \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Ultrasonic_Meter_Setup_Cheat_Sheet_Rev_7.pdf?v=1613684951\" title=\"Cheat Sheet\" target=\"_blank\"\u003eCheat Sheet\u003c\/a\u003e to configure your meter as required.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"youtube-lite\" data-id=\"V4mYT-MHojM\"\u003e\n\u003cdiv class=\"youtube-lite__thumbnail\"\u003e\n\u003cimg src=\"https:\/\/img.youtube.com\/vi\/V4mYT-MHojM\/hqdefault.jpg\" alt=\"Video Thumbnail\" loading=\"lazy\"\u003e \u003cbutton class=\"youtube-lite__play\"\u003e▶\u003c\/button\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan style=\"color: #000000;\"\u003e\u003cstrong\u003e\u003cspan style=\"background-color: #ffff00;\"\u003eWhere to get Power Supplies, Gaskets, Nuts and Bolts\u003c\/span\u003e \u003cspan style=\"color: #2b00ff;\"\u003e\u003ca style=\"color: #2b00ff; text-decoration: underline;\" title=\"Where to get 24 VDC Power Supplies and flange bolts and gaskets\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Power_Supplies_Bolts_Gaskets_and_more.pdf?v=1605288973\" target=\"_blank\"\u003eLink\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Tactical Flow Meter","offers":[{"title":"1\/2\" \/ ANSI","offer_id":43685480497321,"sku":"UltraI-AN-1_2","price":2000.0,"currency_code":"USD","in_stock":true},{"title":"1\/2\" \/ TriClover","offer_id":43685480530089,"sku":"UltraI-TC-1_2","price":2100.0,"currency_code":"USD","in_stock":true},{"title":"3\/4\" \/ ANSI","offer_id":43685480562857,"sku":"UltraI-AN-3_4","price":2010.0,"currency_code":"USD","in_stock":true},{"title":"3\/4\" \/ TriClover","offer_id":43685480595625,"sku":"UltraI-TC-3_4","price":2110.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ ANSI","offer_id":41677532201129,"sku":"UltraI-AN-1","price":2020.0,"currency_code":"USD","in_stock":true},{"title":"1\" \/ TriClover","offer_id":41678119076009,"sku":"UltraI-TC-1","price":2120.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ ANSI","offer_id":41677532233897,"sku":"UltraI-AN-1_1_2","price":2300.0,"currency_code":"USD","in_stock":true},{"title":"1 1\/2\" \/ TriClover","offer_id":41678119108777,"sku":"UltraI-TC-1_1_2","price":2400.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ ANSI","offer_id":41677532266665,"sku":"UltraI-AN-2","price":2200.0,"currency_code":"USD","in_stock":true},{"title":"2\" \/ TriClover","offer_id":41678119141545,"sku":"UltraI-TC-2","price":2300.0,"currency_code":"USD","in_stock":true},{"title":"2 1\/2\" \/ ANSI","offer_id":41677532299433,"sku":"UltraI-AN-2_1_2","price":2300.0,"currency_code":"USD","in_stock":true},{"title":"2 1\/2\" \/ TriClover","offer_id":41678119174313,"sku":"UltraI-TC-2_1_2","price":2400.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ ANSI","offer_id":41677532332201,"sku":"UltraI-AN-3","price":2500.0,"currency_code":"USD","in_stock":true},{"title":"3\" \/ TriClover","offer_id":41678119207081,"sku":"UltraI-TC-3","price":2600.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ ANSI","offer_id":41677532364969,"sku":"UltraI-AN-4","price":2600.0,"currency_code":"USD","in_stock":true},{"title":"4\" \/ TriClover","offer_id":41678119239849,"sku":"UltraI-TC-4","price":2700.0,"currency_code":"USD","in_stock":true},{"title":"6\" \/ ANSI","offer_id":41677532397737,"sku":"UltraI-AN-6","price":3600.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/304SSInlineUltrasonicLogo.webp?v=1758048168"},{"product_id":"low-flow-gas-mass-flow-meter","title":"100 SLPM Low Flow Tactical Flow Meter With Display","description":"\u003ch2\u003e\u003cstrong\u003eMASS FLOW METER 0- 100 SLPM SIZE FLOW METER\u003c\/strong\u003e\u003c\/h2\u003e\n\u003ch2\u003e\n\u003cstrong\u003e\u003c\/strong\u003e\u003cb\u003eSpecifications\u003c\/b\u003e\n\u003c\/h2\u003e\n\u003ch3 style=\"float: left;\"\u003e\u003cb\u003e\u003cimg alt=\"\" src=\"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/LCD_MassFlowMeter_compact.png?v=1527362451\" style=\"float: left;\"\u003eFeatures LARGE LCD display, shows the Flow Rate, Total Flow, Temperature, Flow Units, Total Units, Temperature Units,.\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cb\u003eAnalog output and ModBus RTU then a power supply of 12-24 VDC with a capability of 50 mA must be used to power the meter.  \u003c\/b\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eFlow Body Material 316 SS\u003c\/li\u003e\n\u003cli\u003e100 SLPM relative to Nitrogen Other ranges available on special order.\u003c\/li\u003e\n\u003cli\u003eAccuracy: +\/- 1.5% of reading + 0.5% FS\u003c\/li\u003e\n\u003cli\u003eRepeatability of +\/- 0.5% of reading\u003c\/li\u003e\n\u003cli\u003e3\/8\" Male NPT\u003c\/li\u003e\n\u003cli\u003eLCD Display\u003c\/li\u003e\n\u003cli\u003eMeasures any inert gas and any non-condensing clean gas.\u003c\/li\u003e\n\u003cli\u003eFlammable gases: methane, propane, digester gas, natural gas\u003c\/li\u003e\n\u003cli\u003e100:1 turndown\u003c\/li\u003e\n\u003cli\u003eTemperature:                \u003c\/li\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eGas: 14°F (-10°C) to 131°F (55°C)\u003c\/li\u003e\n\u003cli\u003eAmbient: 14°F (-10°C) to 149°F (65°C)              \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cli\u003eSUPER FAST Response time 250 milliseconds.\u003c\/li\u003e\n\u003cli\u003ePower Requirement: 12 to 24 VDC (regulated), 50 mA maximum;   \u003c\/li\u003e\n\u003cli\u003eWetted Materials may include: 316 stainless-steel, Silicon Nitride, Pyrex Glass, Alumina ceramics, gold, aluminum, nickel, FR-4 and Pb-free solder may come in contact with gas.\u003c\/li\u003e\n\u003cli\u003eOutput signals: Modbus RTU, 4–20 mA , 0–5 VDC, and User definable pulse  output (3VDC) for flow rate indication. Totalizer is non-resettable suitable for billing applications. \u003c\/li\u003e\n\u003cli\u003eDigital communications: Modbus RTU \u003c\/li\u003e\n\u003cli\u003eProof Pressure 1.2 MPa, 175 PSIG.\u003c\/li\u003e\n\u003cli\u003eNEMA 1 Enclosure for Lab and indoor use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TMF5000-Quick-User_Manual-Rev2.5.pdf?v=1662147957\" target=\"_blank\" title=\"Model 5000 Mass Flow Meter Quick Manual Rev 2.5\" rel=\"noopener noreferrer\"\u003eBrochure and Quick Manual\u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TMF5000-Quick-User_Manual-Rev2.5.pdf?v=1662147957\" title=\"Model 5000 Mass Flow Meter Quick Manual Rev 2.5\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/TMF5000-Quick-User_Manual-Rev2.5.pdf?v=1662147957\"\u003e \u003c\/a\u003e(QR Code for Smart Phone Uaers)\u003c\/p\u003e\n\u003cp\u003e \u003cimg data-mce-fragment=\"1\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/QRCode_TFM-5000_R2.5_480x480.png?v=1662148251\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/QRCode_TFM-5000_R2.5_480x480.png?v=1662148251\"\u003e\u003c\/p\u003e\n\u003cp\u003eModBus Poll example register use.\u003c\/p\u003e\n\u003cdiv style=\"text-align: left;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/files\/Low-Flow-Meter-ModBus-Poll-Infographicpng_2048x2048.png?v=1622662289\" alt=\"Low FLow Meter ModBusPoll Infographic\" style=\"float: none;\"\u003e\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eGas K-Factors for GCF Term:\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eAir (calibrated gas, GCF = 1000), N2 (no change, GCF = 1000), O2 (no change, GCF = 1000); Argon (GCF=1150); and CO2 (GCF=740). \u003c\/span\u003e\u003c\/p\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cul style=\"font-weight: 400;\"\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e","brand":"Tactical Flow Meter","offers":[{"title":"0-100 SLPM \/ I have my own","offer_id":42534722338985,"sku":"5000-100SLM-6 100 lpm no conn","price":2548.0,"currency_code":"USD","in_stock":true},{"title":"0-100 SLPM \/ DB-15 with 8' Cable","offer_id":42534722371753,"sku":"5000-100SLM 100 lpm 8 ft cable","price":2598.0,"currency_code":"USD","in_stock":true},{"title":"0-100 SLPM \/ DB-15 with 10' Cable","offer_id":42534722404521,"sku":"5000-100SLM 100 lpm 10 ft cable","price":2623.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/products\/TFM-5000MeterOverview.png?v=1663349176"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1571\/4565\/collections\/1InBlueDisp2.png?v=1477680327","url":"https:\/\/www.tacticalflowmeter.com\/collections\/frontpage\/natural-gas-flow-flow-meter.oembed","provider":"Tactical Flow Meter","version":"1.0","type":"link"}