1/2" to 4" Coriolis Mass Flow Meter..
Regular price
$11,500.00
Sale
CORIOLIS MASS FLOW METER, 1/2", 1", 2", 3" & 4" ANSI PIPE FLANGE SIZE RANGES AND 1/4" Swage to 1/2" Swage for low flows and high pressure
Coriolis Mass Flow Meters at the prices of high end Thermal or Vortex Mass Flow Meters do not require any upstream plumbing. Accuracy: 0.2% to 0.5% of READING
Coriolis Flow Meter Display
Features LARGE LCD display, shows the Instantaneous (Instant) Flow Rate, Total Flow, Temperature, and Density in user selectable units.
Coriolis Mass Flow Meter Specifications.
- Wetted Materials all 316 SS
- Flows from 0.1 kg/h to 200,000 kg/h relative to water
- Accuracy: +/- 0.2% or 0.5% of reading in gas or water. 0.1% available on special order. Note turndown typically 10:1
- Repeatability of +/- 0.02% of reading
- 1/2" to 4" 150# ANSI Flange Connections, up to 6" available custom as well as 1/4" Swage to 1/2" Swage.
- LCD Display
- Temperature Accuracy +/- 1 Deg C
- Temperature:
- Gas: -58°F (-50°C) to 257°F (125°C)
- Ambient: -40°F (-40°C) to 131°F (55°C)
- Power Requirement: 24 VDC or 85-220 VAC, 15 Watts maximum;
- Output signals: Modbus RTU, 4–20 mA, and 0-10 KHz for flow rate indication
- Digital communications: Modbus RTU
- Proof Pressure 4.0 MPa, 580 PSIG, with higher pressures for low flows.
- Display: Flow rate, Total flow, Temperature, and Density
- Wiring connection to enclosure size: M20 x 1.5
- Factory Final QC Test Certificate
- Integral Electronics installation
- Explosion Proof Rating: ExdibIICT5Gb
- Electronics Enclosure NEMA 4X / IP67
Coriolis Meter Quick User Manual and Spec Sheet Download
Mounting Guide:
High Pressure, Low Flow Coriolis Mass Flow Meter
High Pressure Low Flow Coriolis Meter Specs
Coriolis Mass Flow Meter User Interface Video
Coriolis User Interface and ModBus RTU
Notes about ZERO Calibration on Coriolis meters.
NOTE: It is critical to invoke the zero point calibration after installation.
Every Coriolis Meter must be zeroed in the final installation point with the fluid that will be measured.
Make sure the meter has warmed up for at least 15 minutes before invoking the zero function. Make sure the measuring tube is fully filled with liquid. Turn off the stop valves, make sure the liquid is in a stationary state, and enter password 20 to invoke calibrate the zero point. The zero function is in process when the display indicates "Adjust zero" for about 30 seconds and then reverts to the normal display mode, after you hit the bottom left Enter button to start the function. This function is CRITICAL to allow the meter to determine the resonant frequency of the measuring tube is to determine the density of the fluid within it. This step cannot be skipped. Once this step is complete you will want to confirm the measured density is accurate.
This is done in the main running screen by touching the up arrow (upper right hand corner) and confirm the indicated density agrees with the density of your fluid.
Coriolis mass flow meters directly measure the mass flow and the density of the fluid. The volume flow rate is calculated by mass flow divided by density. If the density measured at the zero point is not accurate, then the flow rates will be affected as well.
We show the process using the touch screen below
